Lightway PV Modules, Installation Manual, Page
34
/36
www.lightwaysolar.com
Series
1960×992×40
Mono-poly
Series
1956 ×992×40
Mono-poly
Series
1979×1002×40
Mono-poly
Series
LW6M72-335W
335
37.97
8.83
46.45
9.42
1000
15/20
4mm
2
LW6M72-340W
340
38.19
8.91
46.70
9.48
1000
15/20
4mm
2
LW6M72-345W
345
38.45
8.98
46.95
9.52
1000
15/20
4mm
2
LW6M72-350W
350
38.62
9.07
47.20
9.59
1000
15/20
4mm
2
LW6M72-355W
355
38.83
9.15
47.45
9.66
1000
15/20
4mm
2
LW6M72-360W
360
39.03
9.23
47.70
9.73
1000
15/20
4mm
2
LW6M72-365W
365
39.28
9.30
47.95
9.80
1000
15/20
4mm
2
LW6M72-370W
370
39.56
9.36
48.20
9.85
1000
15/20
4mm
2
LW6M72-375W
375
39.79
9.43
48.42
9.91
1000
15/20
4mm
2
LW6M72-380W
380
40.02
9.50
48.64
9.97
1000
15/20
4mm
2
LW6M72-385W
385
40.25
9.57
48.86
10.03
1000
15/20
4mm
2
LW6M72-390W
390
40.47
9.64
49.08
10.09
1000
15/20
4mm
2
1650/1640×990
×40 Mono-poly
Series
1650/1640×992
×40 Mono-poly
Series
1665×1002×40
Mono-poly
Series
1650/1640×990
×35 Mono-poly
Series
1650/1640×992
×35
Mono-poly
Series
1665×1002×35
Mono-poly
Series
LW6M60-260W
260
30.78
8.45
37.61
9.02
1000
15/20
4mm
2
LW6M60-265W
265
31.04
8.54
37.82
9.10
1000
15/20
4mm
2
LW6M60-270W
270
31.22
8.65
38.03
9.18
1000
15/20
4mm
2
LW6M60-275W
275
31.43
8.75
38.24
9.28
1000
15/20
4mm
2
LW6M60-280W
280
31.72
8.83
38.42
9.38
1000
15/20
4mm
2
LW6M60-285W
285
31.92
8.93
38.62
9.48
1000
15/20
4mm
2
LW6M60-290W
290
32.12
9.03
38.82
9.58
1000
15/20
4mm
2
LW6M60-295W
295
32.35
9.12
39.02
9.66
1000
15/20
4mm
2
LW6M60-300W
300
32.58
9.21
39.28
9.75
1000
15/20
4mm
2
LW6M60-305W
305
32.80
9.30
39.50
9.85
1000
15/20
4mm
2
LW6M60-310W
310
33.06
9.38
39.80
9.92
1000
15/20
4mm
2
LW6M60-315W
315
33.28
9.47
40.05
10.01
1000
15/20
4mm
2
LW6M60-320W
320
33.49
9.56
40.29
10.10
1000
15/20
4mm
2
LW6M60-325W
325
33.72
9.64
40.53
10.16
1000
15/20
4mm
2
Nameplate ratings are average values. The electrical characteristics are /- 3 percent of the indicated values of I
sc
,
V
oc
, and P
max
under Standard Test Conditions (irradiance of 1000 W/m
2
, AM 1.5 spectrum, and a cell temperature of
25
).
℃
The t
emperature coefficient are below:
α
=0.0359
,β
=-0.3108
,γ
=-0.4154,
Refer to module data-sheets for
specific power output tolerances.
Series
Module
Pmax
Vmpp
Impp
Voc
Isc
Max. system
voltage (V)
Max. series
fuse rating (A)
Cable
Diameter
(W)
(V)
(A)
(V)
(A)
2008×1002×4
0 Mono-poly
Series
LW6MH72-415
415
42.10
9.86
50.46
10.35
1500
15/20
4mm
2
LW6MH72-410
410
41.80
9.81
50.20
10.30
1500
15/20
4mm
2
LW6MH72-405
405
41.50
9.76
49.95
10.25
1500
15/20
4mm
2
LW6MH72-400
400
41.20
9.71
49.68
10.20
1500
15/20
4mm
2
Содержание LW6M60-260
Страница 15: ...Lightway PV Modules Installation Manual Page 14 36 www lightwaysolar com...
Страница 20: ...Lightway PV Modules Installation Manual Page 19 36 www lightwaysolar com 2006 992 990 40 Multi poly...
Страница 21: ...Lightway PV Modules Installation Manual Page 20 36 www lightwaysolar com 1680 992 990 40 Multi poly...
Страница 22: ...Lightway PV Modules Installation Manual Page 21 36 www lightwaysolar com 1680 992 990 35 Multi poly...
Страница 23: ...Lightway PV Modules Installation Manual Page 22 36 www lightwaysolar com 1979 1002 40 Mono poly Series...
Страница 24: ...Lightway PV Modules Installation Manual Page 23 36 www lightwaysolar com 2008 1002 40 Mono poly Series...
Страница 25: ...Lightway PV Modules Installation Manual Page 24 36 www lightwaysolar com 1845 1002 998 35 Mono poly Series...
Страница 26: ...Lightway PV Modules Installation Manual Page 25 36 www lightwaysolar com 1684 1002 40 35 Mono poly Series...
Страница 27: ...Lightway PV Modules Installation Manual Page 26 36 www lightwaysolar com 1665 1002 40 35 Mono poly Series...