REMOTE  ALARM  CONNECTION  MODULE:  Allows 

for  a  connection  to  a  remote  device  such  as  a 

buzzer, light, alarm system, PLC, etc., via a pair of 

contacts.  In  normal  operation  the  OK  and  COM 

contacts will be connected, and in a fault condition 

(Low UV, Lamp fail, Power Fail), the Fault and COM 

contacts  will  be  connected.  Maximum  contact 

rating is 30V / 1A (use 16-22 AWG).  Order PN LTW-

RAM.

SOLENOID  CONNECTION  MODULE:  Connects  a 

NORMALLY CLOSED line voltage solenoid valve to 

the controller.  Maximum contact rating is 240VAC 

(50-60Hz)  /  30VDC  /  2A.  On  a  non-monitored 

system,  the  solenoid  will  only  close  on  a  lamp 

failure error. On a monitored system, the solenoid 

is  closed  when  the  UV  level  drops  below  50%. 

Also  note  that  in  cases  where  emergency  use  of 

untreated water is required, the controller can be 

placed into a manual override mode allowing for 

the flow of water in an alarm condition. Order PN 

LTW-SOL1.

4-20 mA MODULE: Outputs a 4-20mA signal of the 

UV output to a remote device such as a data logger 

or computer. Order PN LTW-420.

The  WiFi  module  and  accompanying  IoT 

application allows you to connect your UV system 

to  a  smart  phone,  tablet,  computer  or  other 

connected  platform.  View  system  status,  receive 

SMS  or  email  messages  of  alarm  conditions  and 

monitor the health of your UV from anywhere via 

this  connected  platform.  Connect  the  device  via 

the  APP  found  on  Google  Play  or  the  APP  Store 

and connect your UV device to your router, then 

download the software for your connected device 

and  have  peace  of  mind  that  your  UV  system  is 

providing safe, reliable disinfection. Order PN LTW-

MODAPP.

The Ultrasonic Flow Meter enables your UV system 

to dim power in times of low to no flow, saving you 

money  on  energy,  reducing  water  temperature, 

and decreasing the risk of fouling.

Содержание LTW-4 Series

Страница 1: ...403 LTW 503 LTW 603 3 gpm LTW H410 LTW H510 LTW H610 10 gpm LTW 406 LTW 506 LTW 606 6 gpm LTW H415 LTW H515 LTW H615 15 gpm LTW 410 LTW 510 LTW 610 11 gpm LTW H425 LTW H525 LTW H625 25 gpm LTW 415 LTW...

Страница 2: ...pply with a UV system gives you reassurance that your family will have access to safe drinking water throughout your entire home with no chance of microbiological contamination This is chemical free p...

Страница 3: ...5 LTW 6 Controllers 14 LTW 5 LTW 6Power up Sequence 14 LTW 5 Operational Screens 15 LTW 6 Operational Screens 15 Lamp Countdown Sequence 16 System Service Suggested 17 Lamp Replacement LTW 4 systems 1...

Страница 4: ...vice instructions if required 7 Do not use this system for any purpose other than what it was intended for Misuse of this system could potentially cause harm to the user or others 8 Your system is int...

Страница 5: ...ment required will depend on parameters being treated Hardness 7 gpg 120 mg L if hardness level is 7 gpg or slightly below the quartz sleeve must be cleaned periodically in order to ensure effi cient...

Страница 6: ...LTW 390007 Brass Nut UV SENSOR LTW RSB25 LTW 5 6 02 03 06 10 15 series LTW RSB35 LTW 520 LTW 620 series GLAND NUT LTW 320006 O RING LTW 300038 UV LAMP LTW RL210 02 series LTW RL290 03 series LTW RL470...

Страница 7: ...60005 Euro LTW 260006 New Zealand Australian LTW 260008 British GLAND NUT LTW 320006 O RING LTW 300038 UV LAMP LTW RL210HO 05 series LTW RL330HO 10 series LTW RL420HO 15 series LTW RL600HO 25 series L...

Страница 8: ...p near est the pressure system and measure the amount of water drawn off until the pump starts again Depending on the size of the container used it is acceptable to turn the faucet on and off to empty...

Страница 9: ...ded as it will allow you to isolate the UV reactor This will allow for easier access in case maintenance is required See Figure 3 Step 3 Use the supplied fasteners to mount the UV reac tor to wood or...

Страница 10: ...ASE NOTE DO NOT install a UV lamp inside the quartz sleeve without the sleeve spring in place Step 8 Install the UV sensor ordered separately Align the flat portion so it faces the gland nut end and m...

Страница 11: ...ing you The key will plug into the lamp key port on the right side of the controller Figure 8 Step 13 Plug the lamp connector into the lamp Note the keying for proper alignment see Fig ure 7a 7b Inser...

Страница 12: ...equire periodic cleaning At a minimum the quartz sleeve should be cleaned on an annual basis The following steps outline a basic cleaning procedure Step 1 If a by pass assembly is installed shut the i...

Страница 13: ...r and pull the sensor slowly out of the sensor port Step 6 Holding the sensor in your hand wipe the flat portion sensor face of the sensor with isopropyl alcohol using a clean lint free cloth Step 7 R...

Страница 14: ...d description of the system s performance in addition to providing any applicable fault messages and system diagnostics The controllers used in both the LTW 5 and LTW 6 are identical The difference is...

Страница 15: ...s by pressing the button located on the front of the controller LTW 6 Operational Screens On systems with the UV monitor the system will display the same screens as on the LTW 5 except the UV Intensit...

Страница 16: ...dible chirp Past the zero day threshold the LED or display screen changes to solid red with a continuous buzzer LTW 5 LTW 6 LTW 4 At any point during this sequence the audible chirp or alarm can be de...

Страница 17: ...the lamp is expired it must be replaced with the same part number as indicated on the Maintenance Parts screen or on the label on the reactor With the system powered down remove and discard the lamp k...

Страница 18: ...l on the reactor or on the Maintenance parts screen Low UV Intensity Remove and clean the quartz sleeve and sensor Check water quality meets requirements on page 5 and add filtration as required Repla...

Страница 19: ...any module that is not detected when plugged directly into the controller Refer to flow meter manual for detailed troubleshooting Warning After any hard alarm the home or facility should be disinfecte...

Страница 20: ...ates from 90 265V 47 63Hz Order PN LTW 130014 only fits LTW H4 LTW H5 LTW H6 systems Temperature Relief Valve TRV On reaching a higher temperature the TRV is designed to drain a small amount of water...

Страница 21: ...an be placed into a manual override mode allowing for the flow of water in an alarm condition Order PN LTW SOL1 4 20 mA MODULE Outputs a 4 20mA signal of the UV output to a remote device such as a dat...

Страница 22: ...r Watts 8 15 22 39 50 42 Power Watts 14 20 30 49 62 51 Replacement Lamp LTW RL210 LTW RL290 LTW RL470 LTW RL820 LTW RL999 LTW RL850 Replacement Sleeve LTW QS210 LTW QS290 LTW QS470 LTW QS820 LTW QS999...

Страница 23: ...0 5 m3 hr 0 6 m3 hr 1 1 m3 hr 1 8 m3 hr Port Size MNPT MNPT 1 MNPT 1 MNPT 1 MNPT Electrical 90 265V 50 60Hz 1 5A Max Plug Type American NEMA 5 15P Lamp Power Watts 18 34 45 67 101 Power Watts 20 36 48...

Страница 24: ...s outlined below LIGHTWAVE s liability under this warranty shall be limited to repairing or replacing the product without charge F O B LIGHTWAVE s closest Distribution Facility or authorized service d...

Страница 25: ...DISINFECTION PRODUCT AND IS GIVEN IN LIEU OF ANY OTHER WARRANTY TO THE EXTENT ALLOWED BY APPLICABLE LAW ANY AND ALL EXPRESS OR IMPLIED WARRANTIES NOT SET FORTH HEREIN ARE WAIVED AND DISCLAIMED INCLUD...

Страница 26: ...2 6 P a g e...

Страница 27: ...2 7 P a g e...

Страница 28: ...Van Isle Water 461 Dupplin Rd Victoria BC V8Z 1B8 250 383 7145 vanislewater com PN 910415 Version Date 12 2020...

Отзывы: