Soft Alarms: The following remaining errors give a 15 second audible chirp only
System Display
Problem
Resolution
The module indicated is
no longer communicat-
ing to with the system.
Ensure all modules are
connected properly to the
system and to each other.
Modules can be tested
individually by plugging in
one at a time and cycling
power to the system.
Replace any module that is
not detected when plugged
directly into the controller.
Refer to flow meter manual for detailed
troubleshooting
Warning: After any hard alarm, the home or facility should be disinfected. Follow the steps
under the “System Disinfection” heading.
Boil Water Advisory: If any failure occurs on a LIGHTWAVE UV system, the water
must not be used for human consumption until the system is returned to a
safe operational mode. If the water is used for human consumption during this
period, the water must be boiled (minimum 20 minutes at a full boil) prior to
consumption.