7. Programmers’ Reference
series – Extender Application Mode – User's Manual
99
7. Programmers’ Reference
series – Extender Application Mode – User's Manual
99
EXTENDER APPLIC
A
TION MODE
Applied F-series endpoint firmware package: v2.0.0 | Applied R-series endpoint firmware package: v2.0.0 | LDC software: v2.5.9b3
7.4.10. Set the Operation Mode
ATTENTION!
This operation always requires rebooting the device.
The operation mode (transmitter, receiver, or transceiver) of the device can be changed based on the required
application.
Command and Response
ç
CALL•/SYS/MB.setOperationModeAndReset=
<operation_mode>
æ
mO•/SYS/MB.setOperationModeAndReset=
<operation_mode>
Parameters
Parameter
Parameter description
Value
Value description
<operation_mode>
The operation mode of
the endpoint device
Transmitter
The endpoint device is set to
Transmitter
operation mode. See
the details in the
section.
Receiver
The endpoint device is set to
Receiver
operation mode. See the details in
the
section.
Transceiver
The endpoint device is set to
Transceiver
operation mode. See
the details in the
section.
Example
ç
CALL /SYS/MB.setOperationModeAndReset=Transmitter
æ
mO /SYS/MB.setOperationModeAndReset=Transmitter
7.4.11. Query the Application Mode
The application mode of the device can be Extender or Matrix. See the details about the two modes in the
section.
Command and Response
#applicationmode #extendermode #matrixmode
ç
GET•/SYS/MB.ApplicationMode
æ
pr•/SYS/MB.ApplicationMode=
<application_mode>
Parameters
Parameter
Parameter description
Value
Value description
<application_mode>
The application mode of
the endpoint device.
Extender
The endpoint device is in Extender
mode.
Matrix
The endpoint device is in Matrix
mode.
Example
ç
GET /SYS/MB.ApplicationMode
æ
pr /SYS/MB.ApplicationMode=Extender
7.4.12. Application Mode Selection
INFO:
See the details about the two modes in the
INFO:
The
Auto
mode is the recommended application mode setting.
Command and Response
ç
SET•/SYS/MB.ApplicationModeSelection=
<application_mode>
æ
pw•/SYS/MB.ApplicationModeSelection=
<application_mode>
Parameters
Parameter
Parameter description
Value
Value description
<application_mode>
The application mode of
the endpoint device.
Auto
The endpoint device detects the
application mode automatically
based on the connected remote
device.
Extender
The endpoint device is forced to be in
Extender mode.
Matrix
The endpoint device is forced to be in
Matrix mode.
Example
ç
SET /SYS/MB.ApplicationModeSelection=Auto
æ