RE - 82D RACK MOUNT DIMMER
Revision 2.0
OWNERS MANUAL
02/28/2005
www.lightronics.com
Lightronics Inc
509 Central Drive, Virginia Beach, VA 23454
TEL 757 486 3588
NORMAL OPERATION
LEDs located on the front panel of the RE-82D indicate channel levels as you operate faders on your console.
The "VALID SIGNAL" LED will light whenever the dimmer is receiving a control signal within the range of
channels that the dimmer is assigned to. The "Phase A" and "Phase B" LEDs will indicate that power sources are
applied to the dimmer. The fan will run continuously whenever power is applied to the RE-82D. An over-
temperature sensor will shut down all channel output if the dimmer temperature rises above safe limits (
≈
175
°
F
exit air temperature).
RELAY MODE
The two leftmost switches control the "relay" mode. When either switch is in the up position, the channels
associated with that switch operate in non-dim mode. These channels will be either full on or full off depending on
the level of the faders controlling them.
MAINTENANCE AND REPAIR
CIRCUIT BREAKERS AND FUSES
Each channel of the RE-82D is protected by a 20 Amp, fast acting, magnetic circuit breaker located on the front
panel of the unit. If the total load for a channel is greater than 2400 Watts the channel circuit breaker will trip.
There are two 1/2 Amp., 250 Volt, fast acting fuses on the front panel to protect the internal electronic circuits
from an overvoltage condition. These fuses may be replaced ONLY by fuses of the size and type given above.
TROUBLESHOOTING
VERIFY THAT ALL POWER IS REMOVED FROM THE DIMMER BEFORE HANDLING THE UNIT.
•
Verify that the unit channel addresses are correctly set.
•
Check that the console is powered and that console channels are correctly patched or set.
•
Check the control cable between the dimmer and its console.
•
Verify the loads and their connections.
OWNER MAINTENANCE
There are no user serviceable parts inside the unit.
The best way to prolong the life of your unit is to keep is cool, clean, and dry. It is important that the cooling
intake and exit vent holes are clean and unobstructed.
Service by other than Lightronics authorized agents may void your warranty.
OPERATING AND MAINTENANCE ASSISTANCE
If service is required, contact the dealer from whom you purchased the equipment or contact Lightronics, Service
Department, 509 Central Drive, Virginia Beach, VA 23454 TEL 757 486 3588 All items returned for service
must include a description of the problem along with your name address and phone number.
Lightronics recommends that you record the serial number of your unit for future reference.
SERIAL NUMBER ______________________