RE - 82D RACK MOUNT DIMMER 

 

Revision  2.0   

 

 

 

 

 

 

OWNERS MANUAL

 

      

 

 

 

 

 

02/28/2005 

www.lightronics.com 

Lightronics Inc 

 

 

 

 

 

509 Central Drive,  Virginia Beach,  VA  23454   

 

 

 

TEL  757 486 3588 

 

DESCRIPTION 

 
The RE-82D is an 8 channel dimmer with a capacity of 2,400 watts per channel giving a total of 19,200 watts.  
The RE-82D is connected to a control console using the DMX-512 control protocol.  Channels A - D and/or 
channels E - H may be switched to operate in "relay" mode.  In relay mode channels are either full on or full off 
(non-dim) depending on console fader position.  The unit is overcurrent and overtemperature protected.  A fan is 
used to ensure proper cooling. Dimming channels may be reassigned in multiples of 4 channels via switches in 
the front panel.   
 
 
 
 
 
 
 
 
 
 

REPLACE

 ONLY WITH

1/2 AMP, 250V

SLOW BLOW FUSE

REPLACE

 ONLY WITH

1/2 AMP, 250V

SLOW BLOW FUSE

CAUTION

CAUTION

VALID SIGNAL

A

B

C

D

ADDRESS

RE - 82D

DMX - 512
8 X 2.4 KW

E

F

G

H

A - D

E - H

RELAY

RISK

OF

 FIRE

RISK

OF

 FIRE

A

B

C

D

E

F

G

H

PHASE

A

PHASE

B

FUSE

FUSE

20A

20A

20A

20A

20A

20A

20A

20A

 

POWER REQUIREMENTS 

 
Each RE-82D requires BOTH PHASES of a SINGLE PHASE 120/240 VOLT AC service or TWO PHASES of a 
THREE PHASE 120/208 VOLT AC service. The neutral conductor is shared by two hots so it is important that the 
two hots used are of different phases. EACH PHASE must be capable of providing 80 AMPS. Line frequency can 
be either 50 or 60HZ. One or more RE-82D dimmers are to be installed into a standard 19" equipment rack with 
provisions for connection to an appropriate electrical service in accordance with the National Electrical Code. 
 

INSTALLATION  

 

PLACEMENT  
 
The RE-82D is designed to be mounted in a standard 19" equipment rack using the four mounting holes in the 
face plate. If the dimming system will be used for touring shows, it is recommended that you provide additional 
support for the rear of the unit. The dimmer is fan cooled and requires no space between units when multiple 
dimmers are used together in a rack. Air enters the dimmer through slots on the side and exits through holes in 
the bottom of the face plate. Make certain these ventilation holes are not obstructed. Do not place the RE-82D 
where it will be exposed to moisture or excessive heat.  
 
POWER CONNECTIONS 

 

WARNING 

MAKE CERTAIN POWER IS REMOVED FROM THE FEED CIRCUITS 

BEFORE YOU BEGIN INSTALLATION. 

 
 
 
 
 
Power enters the RE-82D through the rear of the unit via a hole sized for 1" conduit. Inside the RE-82D is a 
terminal block with three lugs. The "H1" and "H2" are the line connections or "hots". The center connection 
labeled "N" is the neutral. There is an additional ground lug labeled "G" located near the terminal block.  This lug 
is for connecting the chassis to earth ground.  
 
Consult your local electrical codes to determine the proper wire type and wiring methods for your installation. 
Connect a ground wire to the ground lug "G" first.  Next connect the neutral to the center lug "N" on the terminal 
block, then connect one hot to the lug of the terminal block marked "H1"and the other hot to the "H2" lug of the 
terminal block . 
 