![Lightronics RE-82D Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/lightronics/re-82d/re-82d_owners-manual_1914945003.webp)
Page
3 of 6
RE - 82D RACK MOUNT DIMMER
Revision 2.0
OWNERS MANUAL
02/28/2005
www.lightronics.com
Lightronics Inc
509 Central Drive, Virginia Beach, VA 23454
TEL 757 486 3588
CONTROL SIGNAL
The DMX-512 control signal enters the RE-82D through a 5 pin "XLR" connector on the rear of the unit. A second
connector is used to continue this control signal out to other dimmers in the system. Normally the male
connector is used for the incoming control signal and the female connector is used to loop out to other dimmers.
These connectors are wired in parallel so either connector may be used as input or output. The table below
shows the control signal connector pin assignments.
Connector
Pin #
Signal Name
1 DMX
Common
2
DMX Data -
3
DMX Data +
4 Not
Used
5 Not
Used
OUTPUT CHANNEL CONNECTIONS
The RE-82D can be supplied with one of several rear panel output options. Channel output connections are
according to the the rear panel selected. Channel connections generally proceed from left to right (if you are
facing the rear of the unit). Channel “A” will be on the left end. Connections for load Neutrals are provided. There
is also a ground lug terminal to be used for your load circuits grounds.
OPERATION
CHANNEL ASSIGNMENT
The starting channel of each RE-82D is selected using the DIP switches on the front panel. The diagram below
indicates the actual value of each DIP switch position. A chart at the end of this manual "CHANNEL
ASSIGNMENT SWITCH SETTINGS" provides further information for setting the starting address DIP switches.
256 128 64 32 16 8 4
ON
OFF
ADDRESS
A-D E-H
UP FOR RELAY MODE
Any switch in the up position ADDS the associated value to the starting channel number. All switches down =
starting channel number 1.
For example: to set the starting channel to 13, move the 2nd switch from the right (value 8) and the 1st switch
from the right (value 4) to the up position. For a starting channel of 21, move the third switch from the right (value
16) and the rightmost switch (value 4) to the up position.
MANUAL CONTROL
Dimmer channels can be activated manually by pressing corresponding button switches located on the front
panel. This will latch the associated channel to full on. Push the button again to turn the channel off. The
associated LED will light when the channel is activated.