Lightronics RE-82D Скачать руководство пользователя страница 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

Page

  

3  of  6 

RE - 82D RACK MOUNT DIMMER 

 

Revision  2.0   

 

 

 

 

 

 

OWNERS MANUAL

 

      

 

 

 

 

 

02/28/2005 

www.lightronics.com 

Lightronics Inc 

 

 

 

 

 

509 Central Drive,  Virginia Beach,  VA  23454   

 

 

 

TEL  757 486 3588 

 
CONTROL SIGNAL  

 

The DMX-512 control signal enters the RE-82D through a 5 pin "XLR" connector on the rear of the unit.  A second 
connector is used to continue this control signal out to other dimmers in the system.   Normally the male 
connector is  used for the incoming control signal and the female connector is used to loop out to other dimmers.  
These connectors are wired in parallel so either connector may be used as input or output.  The table below 
shows the control signal connector pin assignments. 
 

Connector 

Pin # 

Signal Name 

1 DMX 

Common 

DMX Data - 

DMX Data + 

4 Not 

Used 

5 Not 

Used 

 
 
 
 
 
 
 
OUTPUT CHANNEL CONNECTIONS 
 
The RE-82D can be supplied with one of several rear panel output options.  Channel output connections are 
according to the the rear panel selected.  Channel connections generally proceed from left to right (if you are 
facing the rear of the unit).  Channel “A” will be on the left end.  Connections for load Neutrals are provided. There 
is also a ground lug terminal to be used for your load circuits grounds. 
 

OPERATION 

 
CHANNEL ASSIGNMENT 
 
The starting channel of each RE-82D is selected using the DIP switches on the front panel.  The diagram below 
indicates the actual value of each DIP switch position.  A chart at the end of this manual "CHANNEL 
ASSIGNMENT SWITCH SETTINGS" provides further information for setting the starting address DIP switches. 
 
 

256  128   64   32   16   8   4  

ON 
 
 
OFF

 
 
 
 
 
 

ADDRESS 

 A-D E-H 

 

UP FOR RELAY MODE

 

 
 
 
Any switch in the up position ADDS the associated value to the starting channel number. All switches down = 
starting channel number 1.  
 
For example: to set the starting channel to 13, move the 2nd switch from the right (value 8)  and the 1st switch 
from the right (value 4) to the up position. For a starting channel of 21, move the third  switch from the right (value 
16)  and the rightmost switch (value 4) to the up position.   
 
MANUAL CONTROL 
 
Dimmer channels can be activated manually by pressing corresponding  button switches located on the front 
panel. This will latch the associated channel to full on.  Push the button again to turn the channel off. The 
associated LED will light when the channel is activated. 
 
 

ORDER DIRECTLY TODAY AT: 

www.BulbAmerica.com

 or CALL TOLL FREE 888-505-2111 