VP PARABOLIC
VPA1G12PR132
Page 2 of 2
1'x4' RECESSED FLUORESCENT, 3" DEEP, 12 CELL (1 ROW) PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR INTENSE VDT USE (PREFERRED)
Lightolier
a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
SECTION 2/Folio G05-10 REV. A
Job Information
Type:
OPTIONS & ACCESSORIES
ACCESS PLATE:
Top Wiring access plate is shipped with fixture as standard.
When access plates are required in advance for wiring convenience, specify sepa-
rately. Order Catalog Number:
ACP CSP
.
ELECTRICAL WIRING OPTIONS:
Consult factory.
FUSING:
Internal fast-blow fusing. SUFFIX:
GLR
.
Internal slow-blow fusing. SUFFIX:
GMF
.
RADIO INTERFERENCE FILTER:
120 or 277 volt, 50 or 60 Hz. One per fixture
standard. SUFFIX:
RF
.
CONTINUOUS ROW INSTALLATION:
For F type fixtures, half-width flanges are
required between fixtures. Order Catalog Number:
1FCTRIM
(each joint).
SPLAY TRIM:
For T ceiling type only. SUFFIX:
CTZ14 S2 SPLAY TRIM
.
AIR CLOSURE STRIPS:
SUFFIX
ACS4
(factory installed).
DRYWALL KIT:
Order Catalog Number:
FK91X4
. Request Folio OA30-10.
CHICAGO PLENUM:
SUFFIX:
CP
.
SPECIFICATIONS
PERFORMANCE:
In an installation of 1 lamp 32W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less
than .79 with a spacing to mounting ratio of 1.6 perpendicular to the lamps. To
meet IES RP-1 preferred for VDT areas the VCP (visual comfort probability) shall
not be less than 94 either crosswise or lengthwise, and the maximum average
brightness at 55°, 65°, 75° and 85° shall not exceed 664,109, 0, and 0 candelas
per square meter respectively in the 0°, 45° and 90° horizontal planes. Candelas
at nadir (0°) not to exceed 967.
AIR HANDLING:
(VPA only) side air passages for air supply or air return.
Optional side closure strips. Air return is also provided through the lamp com-
partment through fixture body ends.
MATERIALS: Chassis parts
are die-formed embossed cold rolled steel.
Housing
is embossed for rigidity with all edges turned-in for safe handling.
LOUVER:
Pre-anodized aluminum (Coilzak® or equal).
FINISH: Louver
—specular low iridescence pre-anodized reflector sheet.
REFLECTOR
: Low-iridescence, semi-specular with low iridescence
specular center section.
Chassis exterior
—black baked polyester enamel.
ELECTRICAL:
Thermally protected class “P” ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS:
I.B.E.W./UL and C-UL.
PHOTOMETRY
MODEL NO. VPA1G12PR132120SO
coefficients of utilization — zonal cavity method
RF
20
20
20
RC
80
50
30
RW
70
50
30
50
30
10
50
30
10
1
81
79
77
74
73
72
72
71
70
2
77
73
70
69
67
65
67
65
63
3
72
67
63
64
61
58
62
59
57
4
67
61
57
59
55
52
57
54
52
5
63
56
51
54
50
47
53
49
46
6
59
52
47
50
46
42
49
45
42
7
55
47
42
45
41
38
45
41
38
8
51
43
37
41
37
34
40
36
33
9
47
38
33
37
33
30
36
32
29
10
43
35
30
34
29
26
33
29
26
visual comfort probability
room size
ceiling height
ceiling height
W
L
8.5
10.0
13.0
16.0
8.5
10.0
13.0
16.0
20
20
93
93
92
82
97
96
95
90
20
30
93
93
92
82
97
96
96
91
20
40
93
93
92
82
97
96
96
92
20
60
93
93
92
83
97
96
96
92
30
20
93
93
93
85
97
96
96
91
30
30
93
93
93
85
97
96
96
92
30
40
93
94
92
85
97
96
96
92
30
60
93
94
93
86
98
96
96
92
30
80
93
94
93
86
98
96
96
92
40
20
93
93
93
86
97
96
96
91
40
30
93
94
92
87
97
96
96
92
40
40
93
94
93
87
98
96
96
92
40
60
93
94
93
87
98
96
96
92
40
80
94
94
93
87
98
96
96
92
40
100
94
94
93
87
98
96
96
82
60
30
93
94
93
87
97
96
96
92
60
40
93
94
93
87
98
96
96
92
60
60
94
94
93
87
98
96
96
92
60
80
94
94
93
87
98
96
96
92
60
100
94
94
93
87
98
96
96
92
100
40
94
94
93
87
98
96
96
92
100
60
94
94
93
87
98
96
96
92
100
80
94
94
93
87
98
96
96
92
100
100
94
94
93
87
98
96
97
92
room cavity ratio
luminaries lengthwise
luminaries crosswise
ORDERING INFORMATION
Explanation of Catalog Number. Example: VPA1G12PR132120SOGLR
VP
VP:
3" Deep
Pre-
anodized
Aluminum
Louver
for intense
VDT use
BLANK
= Standard
N
= NYC Code
BODY STYLE:
A=
Air Handling
S
=Static
1
FIXTURE
WIDTH
CEILING TYPE:
G
= Grid (lay-in T bar)
F
=Flanged (overlap)
Z spline and
plaster frame.
T
=Slot grid or
two-directional
concealed T
(see options)
12
NUMBER OF
CELLS:
1 row of
12 cells
P
LOUVER
FINISH:
P
=Low
Iridescence
Specular
R
REFLECTOR:
R
=Specular
95%
Reflective
1
LAMP
QUANTITY
LAMP/
FIXTURE
LENGTH:
32
=T8
34
=T12
(Nominal 48")
VOLTAGE:
120 or 277
BALLAST TYPE:
1 Lamp Mag. T12
LE
<
20THD
<
10THD
1 Lamp Elec. T8
SO*
H
I
*
LOL Dimming
PS
–
*
Instant Start Standard
Other dimming options, consult factory.
OPTIONS:
Add appropriate
suffix to catalog
no, ie: (GLR)
LER = FP - 59.4
IW - 30.4
BF - 0.88
Comparative yearly lighting energy cost per 1000 lumens = $4.04