background image

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 a Philips Group

Section 1A/Folio E20-32 Rev. A

Job Information

Type:

Lightolier is a Philips group brand

Prismalyte

Plus

PRA2GRFVA26U or 217

Page 2 of 2

2' x 2' Recessed Fluorescent, Floating Lens Frame, Black Reveal

Static or Air Supply/Return, 2 Lamp, T8

Ordering Information

Explanation of Catalog Number. Example: PRA2GRFVA26UUNVHI

Options/Accessories

Special Lenses

: Substitute

VY

for

VA

(standard) = .125" nominal pattern 12 with 7.8 oz. average

weight per square foot. Substitute

VI

for

VA

(standard) = .125" nominal pattern 12 with 6.8 oz.

average weight per square foot.

Radio Interference Filter

: To order one RIF per fixture; SUFFIX:

R

.

To order one RIF per ballast; SUFFIX:

B

.

Air Closure Strip

: SUFFIX

ACS2

(factory installed).

Electrical Wiring Options

: Consult factory.

Drywall Kit

: Order Catalog Number:

FK92X2

.

(Request Folio OA30-10 Rev. A).

Chicago Plenum

: SUFFIX:

C

.

Specifications

Performance

: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1,

reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .76. To prevent
glare the VCP shall be not less than 41 either lengthwise or crosswise (at 100fc level) and
the average brightness at 65° shall not exceed 2572 candelas per square meter. To control
veiling reflections, luminaire output in the 30°-90° zone shall not be less than 66.9%.

Air Handling

: (PRA only) side air passages for air supply or air return. Supply air is dis-

charged vertically. Optional side closure strips. Air return is also provided through the lamp
compartment through fixture body ends.

Specifications (continued)

Materials

:

Chassis parts

are die-formed code gauge cold rolled steel. Housing with side rails hemmed over and hous-

ing ends turned-in for safe handling.

Finish

:

Chassis exterior

–black baked polyester enamel.

Cavity

–white baked polyester enamel minimum 86%

reflectance. Phosphate undercoating.

Lenses

:

VA

(standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge,

.095" nominal thickness (similar to pattern 12).

VY

(optional) .125" nominal pattern 12 with 7.8 oz. average

weight per square foot.

VI

(optional) .125" nominal pattern 12 with 6.8 oz. average weight per square foot.

Electrical

: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use

wire suitable for at least 90°.

Labels

: I.B.E.W. UL and ULc Listed.

This product may have a mercury containing lamp.
Manage in accord with Disposal Laws. See: www.lamprecycle.org

Photometry

Model No. PRA2GRFVA26U120SO

LER = FP - 58.4 IW - 56.5 BF - 0.87
Comparative yearly lighting energy cost per 1000 lumens = $4.25

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.

coefficients of utilization — zonal cavity method

(effective floor cavity reflectance 0.20)

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

79

76

73

71

69

67

68

66

65

2

72

67

62

63

60

57

61

58

55

3

66

60

54

56

52

49

54

51

48

4

61

53

48

51

46

42

49

45

42

5

57

48

42

46

41

37

44

40

37

6

53

44

38

42

37

33

41

36

33

7

49

40

34

38

33

29

37

33

29

8

46

36

31

35

30

26

34

30

26

9

43

34

28

32

27

24

32

27

24

10

40

31

26

30

25

22

29

25

22

visual comfort probability

(rated lumens per lamp 3150.)

room size

ceiling height

ceiling height

W

L

8.5

10.0

13.0

16.0

8.5

10.0

13.0

16.0

20

20

57

61

67

73

54

58

64

70

20

30

49

53

58

64

46

50

55

60

20

40

46

48

53

57

42

45

49

54

20

60

42

45

48

52

38

41

43

48

30

20

58

63

67

72

56

61

65

70

30

30

50

54

58

63

47

51

55

60

30

40

46

49

52

56

42

45

49

53

30

60

42

45

47

50

39

41

43

47

30

80

41

43

43

47

38

39

40

43

40

20

60

64

68

72

58

63

67

70

40

30

51

55

59

63

49

53

57

61

40

40

47

50

53

56

44

47

50

53

40

60

43

46

47

50

40

42

43

47

40

80

42

43

43

46

38

40

40

43

40

100

42

43

42

44

39

39

38

40

60

30

52

56

60

64

51

55

58

62

60

40

48

50

53

57

45

48

51

55

60

60

44

46

47

50

41

43

44

48

60

80

42

44

43

46

39

40

40

43

60

100

42

43

42

44

39

39

38

40

100

40

51

53

55

59

49

52

54

57

100

60

47

48

48

52

45

46

46

50

100

80

45

45

45

48

43

43

42

45

100

100

44

44

43

45

42

41

40

41

room

cavity

ratio

luminaries

lengthwise

luminaries

crosswise

Prismalyte

Plus:

Floating

Lens Frame

Recessed

Fluorescent

Troffer

Body Style:
A

=Air

Handling

S

= Static

2

Fixture

Width

Ceiling Type:

G

= Grid

(lay-in T bar)

T

= Slot grid or

two-directional
concealed T
see options)

RF

Lens Frame:

RF

=1/2" regressed

floating aluminum
frame with 7/16"
black reveal four
sides.

Lens Shielding

Type:

VA

=Virgin acrylic

(standard), see
options and
consult factory

2

Lamp

Quantity

Lamp Type/

Fixture Length:

6U

= 6"U Lamp T8

17

= T8

(Nominal 24")

Note:

For

Linear

T5 Lamp

option,

consult factory

Options:

Add appropriate suffix to

catalog no., ie: (C)

Ballast Type:

<

20THD

<

10THD

1–2 Lamp Elec. T8

SO *

H

I

*

LOL T8 Dimming

PS

*Instant Start Standard
Other dimming options. Consult factory.

NOTE:

For

T8 UNV

, you must use

H

I

Ballast Code.

Voltage:

120, 277 or

UNV

=120-277

PR

Standard Prismalyte Plus

PK

For NYC Code – I.B.E.W. Manufactured

PX

For NYC Code – Local 3 Manufactured

Отзывы: