LED Floodlight with PIR
Models: PEL01012 PEL01013
PEL01014 and PEL01015
Please read these instructions carefully before use and retain for future
reference.
This floodlights must be installed by a qualified electrician in accordance with current
building and IET wiring regulations (BS7671).
IMPORTANT SAFETY INFORMATION
•
Do not use PVC cable to connect this floodlight to your wiring supply. Rubberised
cable (type H05RN-F), with three conductors of at least 1.0mm² cross-sectional
area must be used. This product must be connected to Earth.
•
The front of this floodlight is made of tempered glass, replace if cracked.
•
LED lamps are extremely bright. To avoid possible damage to the eyes, do not
stare into an LED beam.
•
In use, avoid touching any external surface of the floodlight, due to the possibility
of high temperatures.
•
Do not use near flammable materials.
•
The floodlight must be positioned so that there is at least 1m between the front of
the work light and the surface to be illuminated.
•
It is suitable for use in an ambient temperature between -30°C and +45°C.
Terminal block is not included. Installation may require advice from qualified
personnel.