background image

Lighting Systems

 

Baselyte-BSL3

Page 2 of 8   

4 Light T8 Direct/Indirect

Lightolier 

a Genlyte Company 

www.lightolier.com

63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470

We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.

Job Information 

Type:

Performance

Candlepower Curve

Candlepower Summary

Coefficients of Utilization

-ODULE,ENGTH

-OUNTING$ISTANCE

-ODULE,ENGTH-OUNTING$ISTANCE

-ODULE,ENGTH-OUNTING$ISTANCE

@

@

@

Module Lengths & Mounting Distances

Note

: Shaded area indicates locations of emergency sections (emergency wiring  

controls all lamps or optional battery pack controls one or two lamps).

Joiner

BSLESW

 = suspended standard white 

Dust Cover

End Set

BSLJS

 = suspended joiner

BSLDCS 

= 4’ suspended dust cover 

System Components & Accessories

Run Configuration 

*Note

: Additional power mounts may be required for some runs with T5 HO 

lamping options, longer runs, and runs with wiring options that are more complex. 
Please consult factory for assistance.

Report No:

 20582

Lamps: 

F32T8

Lumens per Lamp: 

2950

Efficiency: 

82.9%

Up:

 8.9%  

Down:

 8.%

Run

Length

 

4’ 

Module

8’

Module

2’ 

Module

Joiner

End Set

Mount

Power 

Mount*

4’ run

8’ run

2’ run

6’ run

2

2

20’ run

2

24’ run

2

2

28’ run

2

2

3

32’ run

2

3

Zonal Lumen Summary

ZONE 

LUMENS  %BARE LAMP        %LUMINAIRE

CANDLEPOWER SUMMARY

ZONE

CANDLEPOWER

DEG.

0

22.5

45

67.5

90

180

2401

2401

2401

2401

2401

175

2387

2386

2387

2386

2389

165

2302

2297

2310

2321

2332

155

2143

2141

2197

2251

2279

145

1912

1925

2053

2172

2220

135

1619

1667

1881

1994

2046

125

1275

1380

1606

1697

1755

115

889

1047

1230

1205

1262

105

482

628

698

661

746

95

116

148

205

182

251

90

10

34

51

61

65

85

29

45

67

73

77

75

66

84

133

117

119

65

118

171

226

259

273

55

237

247

329

355

373

45

376

327

402

453

471

35

513

426

436

495

521

25

638

551

521

518

522

15

739

681

634

600

598

5

800

789

768

740

742

0

808

808

808

808

808

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

% WALL REFLECTANCE

50

30

10

50

30

10

50

30

10

0

82

82

82

72

72

72

54

54

54

1

71

68

65

63

60

58

47

45

44

2

62

57

53

55

51

47

41

38

36

3

54

49

44

48

43

39

36

33

30

4

48

42

37

42

37

33

32

28

25

5

42

36

31

38

32

28

28

25

22

6

38

31

27

34

28

24

25

22

19

7

34

28

23

30

25

21

23

19

16

8

31

25

20

27

22

18

21

17

14

9

28

22

18

25

20

16

19

15

13

10 25

20

16

22

18

14

17

14

11

ZONAL LUMEN SUMMARY

ZONE LUMENS % BARE LAMP

%LUMINAIRE

0-90
90-180
0-180

9784

8008.5

1775.5

18.1
81.9
100.0

15.0
67.9
82.9

COEFFICIENTS OF UTILIZATION

% EFFECTIVE CEILING CAVITY REFLECTANCE

80

70

50

% WALL REFLECTANCE

50

30

10

50

30

10

50

30

10

0

82

82

82

72

72

72

54

54

54

1

71

68

65

63

60

58

47

45

44

2

62

57

53

55

51

47

41

38

36

3

54

49

44

48

43

39

36

33

30

4

48

42

37

42

37

33

32

28

25

5

42

36

31

38

32

28

28

25

22

6

38

31

27

34

28

24

25

22

19

7

34

28

23

30

25

21

23

19

16

8

31

25

20

27

22

18

21

17

14

9

28

22

18

25

20

16

19

15

13

10 25

20

16

22

18

14

17

14

11

ZONAL LUMEN SUMMARY

ZONE LUMENS % BARE LAMP

%LUMINAIRE

0-90
90-180
0-180

9784

8008.5

1775.5

18.1
81.9
100.0

15.0
67.9
82.9

Содержание Lighting Systems Baselyte-BSL3

Страница 1: ...pper independently tested to meet stringent safety requirements Electrical All luminaires are factory pre wired to module ends with quick wire connectors Joints Intersections Self aligning joining sys...

Страница 2: ...1 2401 2401 175 2387 2386 2387 2386 2389 165 2302 2297 2310 2321 2332 155 2143 2141 2197 2251 2279 145 1912 1925 2053 2172 2220 135 1619 1667 1881 1994 2046 125 1275 1380 1606 1697 1755 115 889 1047 1...

Страница 3: ...nded aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture 65 lbs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7 s...

Страница 4: ...ngth 1 Power Mount 2 4 8 12 3 Conductor BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13 4 Conductor BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14 7 Conductor BSLM3102P17 BSLM3104P17 BSLM3108P17 BSLM...

Страница 5: ...tor BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23 Non Power Mount BSLM1102N BSLM1104N BSLM1108N BSLM1112N Meets UBC OSHPD and DSA seismic requirements Canopy Diameter of 5 1 4 x 3 4 power Cable 7x7...

Страница 6: ...50 All lamps wired on one circuit plus a battery pack is wired to one lamp A hot lead is connected to the battery pack and would function as a trigger wire when connected to a constant hot by installe...

Страница 7: ...gency Battery Pack EM Note Multi lamp battery packs are also available 2 Circuit Center Outer Switching with Emergency Circuit Night Light EC NL One 4 section in two circuit fixture center outer switc...

Страница 8: ...ack EM Note Multi lamp battery packs are also available Fixture wired for two circuit Lamps wired for A B switching in alternate 4 sections 2 Circuit A B Switching alternate 4 sections 2 Circuit A B S...

Отзывы: