background image

Lighting Systems

 

Baselyte-BSL3

Page 5 of 8   

4 Light T8 Direct/Indirect

Lightolier 

a Genlyte Company 

www.lightolier.com

63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470

We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.

Job Information 

Type:

Mount Type: Non-Accessible Ceilings (concrete, gypsum etc.)

Supension Length

Non-Power Mount

1-Power Mount

2-Power Mount

1-Power Mount

2’

4’

8’

12’

  3 Conductor

BSLM1102P13 BSLM1104P13 BSLM1108P13 BSLM1112P13

  4 Conductor

BSLM1102P14 BSLM1104P14 BSLM1108P14 BSLM1112P14

  7 Conductor

BSLM1102P17 BSLM1104P17 BSLM1108P17 BSLM1112P17

2-Power Mount

  3 Conductor

BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23

Non-Power Mount

BSLM1102N

BSLM1104N

BSLM1108N

BSLM1112N

•   Meets UBC, OSHPD and DSA seismic requirements

•   Canopy: Diameter of 5 

/4

“x 

3/4

” (power)

•   Cable: 7x7 stranded aircraft cable

•   Mountable on 0º - 5º sloped ceiling

•   Optional Chicago Plenum approved version available (A4)

•   J-Box: 4” octogonal box (supplied by others)

•   Fully vertically adjustable at fixture

•  Max. 0 amps
•  Max. 300V

•  Max. 0 amps in a  circuit application
•  Max. 5 amps per circuit in a 2 circuit application
•  Max. 300V 
•  Good for 2 circuit feeds or a  circuit feed with  
 

a battery pack hot lead

•  20V or 277V applications

•  Max. 0 amps in a  circuit application 
•  Max. 5 amps per circuit in a multi-circuit    
 

application

•  Good for 3 circuit feeds or 2 circuit feeds with a  
 

battery pack hot lead

•  20V or 277V applications
  

3 Conductor

4 Conductor

7 Conductor

Cord Types

Содержание Lighting Systems Baselyte-BSL3

Страница 1: ...pper independently tested to meet stringent safety requirements Electrical All luminaires are factory pre wired to module ends with quick wire connectors Joints Intersections Self aligning joining sys...

Страница 2: ...1 2401 2401 175 2387 2386 2387 2386 2389 165 2302 2297 2310 2321 2332 155 2143 2141 2197 2251 2279 145 1912 1925 2053 2172 2220 135 1619 1667 1881 1994 2046 125 1275 1380 1606 1697 1755 115 889 1047 1...

Страница 3: ...nded aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture 65 lbs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7 s...

Страница 4: ...ngth 1 Power Mount 2 4 8 12 3 Conductor BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13 4 Conductor BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14 7 Conductor BSLM3102P17 BSLM3104P17 BSLM3108P17 BSLM...

Страница 5: ...tor BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23 Non Power Mount BSLM1102N BSLM1104N BSLM1108N BSLM1112N Meets UBC OSHPD and DSA seismic requirements Canopy Diameter of 5 1 4 x 3 4 power Cable 7x7...

Страница 6: ...50 All lamps wired on one circuit plus a battery pack is wired to one lamp A hot lead is connected to the battery pack and would function as a trigger wire when connected to a constant hot by installe...

Страница 7: ...gency Battery Pack EM Note Multi lamp battery packs are also available 2 Circuit Center Outer Switching with Emergency Circuit Night Light EC NL One 4 section in two circuit fixture center outer switc...

Страница 8: ...ack EM Note Multi lamp battery packs are also available Fixture wired for two circuit Lamps wired for A B switching in alternate 4 sections 2 Circuit A B Switching alternate 4 sections 2 Circuit A B S...

Отзывы: