background image

Calculite

®

HID Downlight 

C9E28VW

Page 2 of 2

9" Aperture, ED28 (Enclosed) Metal Halide, Wide Beam

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2003 Genlyte Thomas Group LLC (Lightolier Division) • A0504 PJF6/2

Job Information

Type:

CEILING

80%

70%

50%

30%

WALL

70 50

30

10

50 10

50

10

50

10

RCR

0

.65 .65 .65 .65

.64 .64

.61 .61

.58 .58

.55

1

.62 .61 .60 .58

.60 .57

.57 .56

.55 .54

.51

2

.59 .57 .55 .53

.56 .52

.54 .51

.53 .50

.48

3

.56 .53 .50 .48

.52 .48

.51 .47

.49 .46

.45

4

.54 .49 .46 .44

.49 .44

.48 .43

.47 .43

.42

5

.51 .46 .43 .40

.45 .40

.44 .40

.44 .39

.38

6

.48 .43 .40 .37

.42 .37

.42 .37

.41 .36

.35

7

.45 .40 .36 .34

.39 .34

.39 .34

.38 .33

.32

8

.42 .37 .33 .31

.36 .31

.36 .31

.35 .31

.30

9

.40 .34 .30 .28

.34 .28

.33 .28

.33 .28

.27

10

.37 .31 .28 .25

.31 .25

.31 .25

.30 .25

.24

LUMINAIRE INPUT WATTS = 205

ANGLE

MEAN CP

LUMENS

0

5084

5

4974

472

10

4744

15

4560

1296

20

4430

25

4102

1899

30

3781

35

3410

2067

40

2559

45

1567

1207

50

542

55

55

147

60

2

65

0

1

70

0

75

0

0

80

0

85

0

0

90

0

175W ED28

G.E. MH COATED LAMP, LUMEN RATING = 12900 LMS, ADVANCE MAGNETIC BALLAST, CL FINISH TRIM 

Coefficients of Utilization

LUMINANCE SUMMARY CD. / SQ. M.      

ANGLE       MEAN CD/SQ M        

45

54182

55

2330

65

0

75

0

85

00

**  EFFICIENCY = 54.9%  **

CERTIFIED TEST REPORT NO. 2474FR, DATE: FEB 20, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**

CANDLEPOWER DISTRIBUTION

ZONAL LUMENS AND PERCENTAGES

ZONE LUMENS

% LAMP %LUMINAIRE

0-30

3667

28.43

51.74

0-40

5734

44.45

80.9

0-60

7087

54.95

99.99

0-90

7088

54.95

100.00

40-90

1353

10.5

19.1

60-90

0

0

0.01

90-180

0

0

0

0-180

7088

54.95

100.00

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

30°

60°

2,500

1,250

3,750

5,000

CEILING

80%

70%

50%

30%

WALL

70 50

30

10

50 10

50

10

50

10

RCR

0

.64 .64 .64 .64

.62 .62

.59 .59

.57 .57

.53

1

.61 .59 .58 .57

.58 .56

.56 .54

.54 .53

.50

2

.58 .56 .53 .52

.55 .51

.53 .50

.51 .49

.47

3

.55 .52 .49 .47

.51 .47

.50 .46

.48 .45

.44

4

.52 .48 .46 .43

.48 .43

.47 .43

.46 .42

.41

5

.50 .45 .42 .40

.45 .40

.44 .39

.43 .39

.38

6

.47 .42 .39 .37

.42 .37

.41 .36

.40 .36

.35

7

.44 .39 .36 .34

.39 .34

.38 .33

.37 .33

.32

8

.42 .36 .33 .31

.36 .31

.36 .31

.35 .31

.30

9

.39 .34 .31 .28

.33 .28

.33 .28

.33 .28

.27

10

.37 .31 .28 .26

.31 .26

.31 .26

.30 .26

.25

LUMINAIRE INPUT WATTS = 290

ANGLE

MEAN CP

LUMENS

0

7668

5

7576

723

10

7473

15

7346

2071

20

7055

25

6243

2887

30

5410

35

4670

2861

40

3470

45

2195

1667

50

753

55

68

201

60

9

65

3

4

70

0

75

0

0

80

0

85

0

0

90

0

250W ED28

PHILIPS MH COATED LAMP. LUMEN RATING = 19475 LMS, UNIVERSAL MAGNETIC BALLAST, CL FINISH TRIM

Coefficients of Utilization

LUMINANCE SUMMARY CD. / SQ. M.      

ANGLE       MEAN CD/SQ M        

45

75909

55

2904

65

169

75

0

85

0

**  EFFICIENCY = 53.5%  **

CERTIFIED TEST REPORT NO. 2472FR, DATE: FEB 20, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**

CANDLEPOWER DISTRIBUTION

ZONAL LUMENS AND PERCENTAGES

ZONE LUMENS

% LAMP %LUMINAIRE

0-30

5680

29.17

54.55

0-40

8542

43.86

82.02

0-60

10411

53.46

99.96

0-90

10414

53.48

100

40-90

1872

9.62

17.98

60-90

3

0.02

0.04

90-180

0

0

0

0-180

10414

53.48

100

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

30°

60°

3,750

5,625

1,875

7,500

SC = 1.1 

SC = 1.1

Отзывы: