background image

60°

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

Calculite

®

HID Downlight

C6E17OVW

Page 2 of 2

6” Aperture, ED17 (Open Rated), Ceramic Metal Halide, Wide Beam

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504

Job Information

Type:

ANGLE

MEAN CP

LUMS.

0

2543

5

2498

238

10

2444

15

2470

698

20

2462

25

2345

1058

30

1990

35

1373

860

40

742

45

264

249

50

19

55

3

6

60

1

65

0

0

70

0

75

0

0

80

0

85

0

0

90

0

ZONAL LUMENS AND PERCENTAGES

ZONE LUMENS

% LAMP %LUMINAIRE

0-30

1993

34.98

64.12

0-40

2854

50.07

91.78

0-60

3109

54.55

99.99

0-90

3109

54.56

100.00

40-90

255

4.48

8.22

60-90

0

0

0.01

90-180

0

0

0

0-180

3109

54.56

100.00

70W ED17

PHILIPS COATED METAL HALIDE LAMP-3K. LUMEN RATING = 5700 LMS, ELECTRONIC AROMAT BALLAST, CL FINISH REFLECTOR

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

20520

55

307

65

0

75

0

85

0

**  EFFICIENCY = 54.6%  

CERTIFIED TEST REPORT NO. 2540FR, 

DATE: NOV  8, 2003

SC = 1.0

S/MH = 1.2   

COMPUTED BY LSI PROGRAM **TEST-LITE**

CANDLEPOWER DISTRIBUTION

ANGLE

MEAN CP

LUMS.

0

36

30

5

3549

338

10

3446

15

3421

968

20

3365

25

3154

1445

30

2817

35

2083

1284

40

1192

45

448

417

50

68

55

19

25

60

8

65

5

5

70

2

75

0

1

80

0

85

0

0

90

0

100W ED17

PHILIPS COATED METAL HALIDE LAMP-3K LUMEN RATING = 8500 LMS. ELECTRONIC BALLAST, CL FINISH REFLECTOR 

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE

MEAN CD/SQ M        

45

34835

55

1782

65

658

75

0

85

0

**  EFFICIENCY = 52.7%  **

CERTIFIED TEST REPORT NO.  2338FR, DATE: OCT 19, 2003

SC = 1.1

S/MH = 1.2  
COMPUTED BY LSI PROGRAM **TEST-LITE**

CANDLEPOWER DISTRIBUTION

ZONAL LUMENS AND PERCENTAGES

ZONE LUMENS

% LAMP %LUMINAIRE

0-30

2751

32.37

61.37

0-40

4034

47.47

90.01

0-60

4477

52.67

99.88

0-90

4482

52.74

100

40-90

447

5.27

9.99

60-90

5

0.06

0.12

90-180

0

0

0

0-180

4482

52.74

100

CEILING

80%

70%

50%

30%

WALL

70 50

30

10

50 10

50

10

50

10

RCR

0

.63 .63 .63 .63

.61 .61

.59 .59

.56 .56

.53

1

.60 .59 .58 .56

.58 .56

.55 .54

.54 .52

.50

2

.57 .55 .53 .52

.54 .51

.53 .50

.51 .49

.47

3

.55 .52 .50 .48

.51 .47

.50 .47

.49 .46

.44

4

.52 .49 .46 .44

.48 .44

.47 .43

.46 .43

.42

5

.50 .46 .43 .41

.45 .41

.44 .40

.44 .40

.39

6

.48 .43 .40 .38

.43 .38

.42 .38

.41 .38

.37

7

.45 .40 .38 .35

.40 .35

.39 .35

.39 .35

.34

8

.43 .38 .35 .33

.37 .33

.37 .33

.37 .32

.32

9

.40 .35 .32 .30

.35 .30

.35 .30

.34 .30

.29

10

.38 .33 .30 .28

.33 .28

.32 .28

.32 .28

.27

LUMINAIRE INPUT WATTS =  110

Coefficients of Utilization

CEILING

80%

70%

50%

30%

WALL

70 50

30

10

50 10

50

10

50

10

RCR

0

.65 .65 .65 .65

.63 .63

.61 .61

.58 .58

.55

1

.62 .61 .60 .59

.60 .58

.58 .56

.56 .54

.52

2

.60 .57 .55 .54

.56 .53

.55 .52

.53 .51

.49

3

.57 .54 .52 .50

.53 .49

.52 .49

.51 .48

.46

4

.55 .51 .48 .46

.50 .46

.49 .45

.48 .45

.44

5

.52 .48 .45 .43

.47 .43

.46 .42

.46 .42

.41

6

.50 .45 .42 .40

.45 .40

.44 .40

.43 .40

.39

7

.47 .43 .40 .38

.42 .37

.41 .37

.41 .37

.36

8

.45 .40 .37 .35

.40 .35

.39 .35

.39 .34

.34

9

.42 .37 .34 .32

.37 .32

.37 .32

.36 .32

.31

10

.40 .35 .32 .30

.35 .30

.34 .30

.34 .30

.29

LUMINAIRE INPUT WATTS = 78

Coefficients of Utilization

1,250

625

1,875

2,500

30°

1,750

3,500

30°

60°

875

2,625

Отзывы: