Lighting Systems
Baselyte-BSL4
Page 2 of 7
Light T5 HO Direct/Indirect
Lightolier
a Genlyte Company
www.lightolier.com
63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • 0205 Rev.
Job Information
Type:
Performance
Candlepower Curve
Candlepower Summary
Coefficients of Utilization
-ODULE,ENGTH
-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
-ODULE,ENGTH-OUNTING$ISTANCE
@
@
@
Module Lengths & Mounting Distances
Note
: Shaded area indicates locations of emergency sections (emergency wiring
controls all lamps or optional battery pack controls one or two lamps).
Joiner
BSLESW
= suspended standard white
End Set
BSLJS
= suspended joiner
System Components & Accessories
Run Configuration
*Note
: Additional power mounts may be required for some runs with T5 HO
lamping options, longer runs, and runs with wiring options that are more complex.
Please consult factory for assistance.
Report No:
20633
Lamps:
F54T5
Lumens per Lamp:
4650
Efficiency:
93.5%
Up:
98.5%
Down:
.5%
Run
Length
4’
Module
8’
Module
2’
Module
Joiner
End Set
Mount
Power
Mount*
4’ run
8’ run
2’ run
6’ run
2
2
20’ run
2
24’ run
2
2
28’ run
2
2
3
32’ run
2
2
3
Zonal Lumen Summary
ZONE
LUMENS %BARE LAMP %LUMINAIRE
CANDLEPOWER SUMMARY
ZONE
CANDLEPOWER
DEG.
0
22.5
45
67.5
90
180
1047
1047
1047
1047
1047
175
1042
1042
1047
1049
1050
165
1002
1011
1034
1051
1058
155
930
951
1007
1051
1067
0
145
826
867
965
1043
1070
1
135
694
766
912
1025
1062
2
125
541
651
850
993
1038
3
115
375
535
777
925
978
4
105
203
421
640
693
707
5
95
55
137
99
35
34
6
90
3
6
8
8
7
7
85
5
5
6
7
6
8
75
7
6
7
8
8
9
65
6
10
10
10
10
10
55
7
11
16
12
12
45
8
9
17
23
23
35
9
9
13
19
21
25
9
10
10
13
13
15
9
10
11
11
11
5
9
9
10
10
10
0
9
9
9
9
9
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
89
89
89
76
76
76
52
52
52
1
77
73
70
66
63
61
45
44
42
2
67
62
57
57
53
50
39
37
35
3
59
52
47
50
45
41
35
31
29
4
52
45
40
44
39
34
30
27
24
5
46
39
33
39
33
29
27
23
21
6
40
34
29
35
29
25
24
20
18
7
36
29
25
31
25
21
22
18
15
8
32
26
21
28
22
19
19
16
13
9
29
23
19
25
20
16
17
14
11
10 27
20
16
23
18
14
16
12
10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP
%LUMINAIRE
0-90
90-180
0-180
4351
4286
65
1.5
98.5
100.0
1.4
92.2
93.6
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80
70
50
% WALL REFLECTANCE
50
30
10
50
30
10
50
30
10
0
89
89
89
76
76
76
52
52
52
1
77
73
70
66
63
61
45
44
42
2
67
62
57
57
53
50
39
37
35
3
59
52
47
50
45
41
35
31
29
4
52
45
40
44
39
34
30
27
24
5
46
39
33
39
33
29
27
23
21
6
40
34
29
35
29
25
24
20
18
7
36
29
25
31
25
21
22
18
15
8
32
26
21
28
22
19
19
16
13
9
29
23
19
25
20
16
17
14
11
10 27
20
16
23
18
14
16
12
10
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARE LAMP
%LUMINAIRE
0-90
90-180
0-180
4351
4286
65
1.5
98.5
100.0
1.4
92.2
93.6