WARRANTY

- The manufacturer shall repair or replace a luminaire that has been found to be defective under

normal  use  through  no  fault  of  the  customer  provided  that  it  was  delivered,  stocked,
mounted/installed and operated in conditions and according to the requirements specified in a
product  data  sheet,  engineering  specifications,  mounting  and  service  instructions,  delivery
terms, rules for technical maintenance of electrical installations and other conditions agreed by
the  manufacturer  and  the  customer  during  the  warranty  period  or  expanded  warranty  period
specified below.

- The  luminaire  is  a  serviceable  device.  When  installing  the  luminaire,  free  access  should  be

provided for service or repair. The manufacturer is not responsible and will not compensate any
expenses related to construction work, rental vehicles etc. in case the repair site is not readily
accessible.
The statutory warranty period is determined by the applicable law, and may vary from country to
country. The manufacturer undertakes statutory warranty obligations in the amount and within
the time frame stipulated by the applicable law.

- Warranty  period  -  60  months  from  date  of  delivery  subject  to  terms  and  conditions  specified

herein and on the manufacturer’s website at https://www.ltcompany.com/en/terms/

- Warranty does not apply to color change of painted surfaces and plastic parts during luminaire

operation.

- The warranty period of emergency power supply units (supplied with rechargeable battery) and

illumination  control  system  components  (supplied  without  luminaires)  is  limited  to  12  (twelve)
months from date of delivery.

- Warranty does not apply to color change of painted surfaces and plastic parts during luminaire

operation. 
Luminous flux level is at least 70% of the nominal value during the warranty period.

- Warranty  will  cover  the  entire  period,  given  that  assembly,  installation  and  operation  of

luminaires  are  handled  by  specialized  technical  personnel  and  according  to  the  luminaire's
manual. 

- The  service  life  of  the  luminaires  under  normal  climatic  conditions  subject  to  installation  and

usage instructions is:
·   8 years – for luminaires with body and/or optical parts (diffuser) made of polymeric materials.
·   10 years - all other luminaries.

- The  manufacturer  reserves  the  right  to  make  modifications  to  the  product  that  improve  its

end-user performance. 
The  manufacturer  is  not  liable  for  typographical  and  other  errors  that  may  have  occurred  in
printing. 

- Storage.

The luminaire should be stored in heated and ventilated warehouses, storages with conditioned
air  which  situated  at  any  climatic  region  and  with  temperature  from  +5  to  +40°С  and  relative
humidity not more than 80%.
NiCd, NiMh batteries: Temperature range +5 to +40°C
When storing for more than 6 months it is recommended to refresh batteries - 5 cycles of
charging-discharging
Transportation in manufacturer's package could be done by any mode of transport as long as
protection from mechanical damage and precipitation is provided.

- Before putting luminaire with emergency power supply unit into operation, it is recommended to

make 3-4 cycles of battery charging-discharging to obtain nominal battery capacity.
Charging  duration  is  24  hours  at  normal  ambient  temperature  and  nominal  power  supply
voltage.

ACCEPTANCE CERTIFICATE

The luminaire meets the requirements of applicable EC directives.
Manufacture date _____________________________________________________________
Inspected by ___________________________________________________________________
Packaged by________________________________________________________________

7

Содержание 1997015290

Страница 1: ...COLIBRI DL LED Manual Montageanleitung ...

Страница 2: ...264 V 50 60 Hz 0 4 Hz and DC 170 280 V network The supply mains must be protected from communication and electric impulse noise The main characteristics of line voltages at a network user s supply terminals in public AC electricity networks should comply EN 50160 2010 For luminaires with emergency power supply unit in case of mains power failure the battery will power the luminaire for at least 3 ...

Страница 3: ... 0 75 186 74 175 85 0 A 0 7 165 5 0 75 Versorgungsnetze müssen vor Kommunikations und elektrischen Impulsgeräuschen geschützt werden Die Netzqualität muss mit EN 50160 2010 übereinstimmen Bei Leuchten mit Notstromversorgung Bei Ausfall der Netzspannung versorgt die Batterie die Leuchte mindestens 3 Stunde mit Strom Der Lichtstrom in diesem Modus ist 350 Der Lichtstrom im Notfallmodus in ist ein Pr...

Страница 4: ...e at a distance of less than 0 5 m Only operate the luminaire if the diffuser is undamaged Unauthorized disassembling modification and repair is prohibited In case of malfunction the luminaire should be immediately switched off and report to manufacturer or specialized luminaire service The luminaire has passed a high voltage test for insulation and electric strength according to IEC 60598 1 The L...

Страница 5: ...d the springs and mount the luminaire in a ceiling niche 6 Attention When removing luminaries it is possible for silicone caps to slip off from springs Before following installation these caps should be placed back on springs 7 For luminaries with backup power supply 7 1 Connect battery to backup power supply unit of external luminaire s module module is linked with luminaire by a means of cable W...

Страница 6: ...r luminaries with external module the module should be put into ceiling recess previously 12 ATTENTION For luminaires with emergency unit it is prohibited to place extension box on the side where the TEST button is located These instructions assume expert knowledge corresponding to a completed professional education as an electrician Overall and installation dimensions mm 1 2 CONNECTION SCHEMES 1 ...

Страница 7: ...ng luminaire operation Luminous flux level is at least 70 of the nominal value during the warranty period Warranty will cover the entire period given that assembly installation and operation of luminaires are handled by specialized technical personnel and according to the luminaire s manual The service life of the luminaires under normal climatic conditions subject to installation and usage instru...

Страница 8: ...Manufacturer company LLC IGC Lighting Technologies Company stamp More information can be found on our website https www ltcompany com en Hotline 0049 89 550 59 8611 8 ...

Страница 9: ...on weniger als 0 5m vermeiden Nehmen Sie die Leuchte nur in Betrieb wenn der Diffusor nicht beschädigt ist Nicht autorisiertes Zerlegen Modifizieren und Reparieren ist verboten Im Falle einer Fehlfunktion sollte die Leuchte sofort ausgeschaltet werden und sich beim Hersteller oder spezialisierten Leuchtenservice melden Leuchte hat einen Hochspannungstest für Isolation und Spannungsfestigkeit gemäß...

Страница 10: ...en L1 N1 N2 L2 L1 N1 Leuchtenversorgung L2 N2 Stromkabel für konstante Batterieladung 5 Die Federn aufbiegen und die Lampe in der Deckennische installieren 6 Achtung Bei der Demontage der Leuchten können sich Silikonkappen von den Federn lösen abrutschen Für die weitere Montage müssen diese Kappen auf die Federn aufgesetzt werden 7 Für Geräte mit einem Backup Netzteil 7 1 Schließen Sie die Batteri...

Страница 11: ...icht mehr als 1 0 kg 11 Machen Sie ein Loch in der Decke des erforderlichen Durchmessers Die Federn aufbiegen und die Lampe in der Deckennische installieren für Leuchten mit einer externen Box Platzieren Sie sie in der Nischenbox 12 BEACHTUNG Bei Leuchten mit einer Notfalleinheit darf die Fernbedienung nicht auf die Seite gelegt werden auf der sich der Testknopf befindet Diese Anleitung geht von e...

Страница 12: ...euchten von spezialisiertem Fachpersonal und gemäß Bedienungsanleitung durchgeführt werden Die Lebensdauer der Leuchte unter normalen klimatischen Bedingungen beträgt mindestens 8 Jahre insofern die Installation und Betriebsanweisungen befolgt werden 8 Jahre für Leuchten mit Gehäuse und oder optischen Teilen Diffusor aus Polymer Materialien 10 Jahre alle anderen Leuchten Der Hersteller behält sich...

Страница 13: ...Firmenstempel Weitere Informationen finden Sie auf unserer Website https www ltcompany com de Hotline Nummer 0049 89 550 59 8611 30 03 2020 2 19 03 13 ...

Отзывы: