19
3. Parameter List
:
Code
Name
Scope
Description
0
Machine Code
1-254
ID code for pump
1
Strokes/Minute
10-180
Pump working frequency
2
Flow Setting
0-999
Setting the flow rate
3
Percentage
0-100
Percentage of the flow
4
RS485 control
0-1
0
:
OFF
1
:
ON
5
Control mode
0-3
0
:
Manual control
1
:
Pulse signal multiply
2
:
Pulse signal division
3
:
4-20mA signal
6
Pulse base
0-255
Base of pulse counts
7
Remote
start/stop
0-1
0
:
OFF
1
:
ON
8
Baud rate
0-2
0:9600 bps
1:19200 bps
2:38400 bps
Setting
:
Long press
button to enter the setting state, press
button to enter the 0-8 cycle options.
0. Machine Code.
1. Set the minimum number of pulses per minute by