background image

Instruction Manual

JLM-S Solenoid Metering Pump

Carefully read and understand all precautions
before installing and servicing.

Содержание JLM-S

Страница 1: ...Instruction Manual JLM S Solenoid Metering Pump Carefully read and understand all precautions before installing and servicing ...

Страница 2: ......

Страница 3: ...ation 9 3 2 Tubing Connections 14 3 3 Food Valve and Suction Tubing Installation 14 3 4 Injection Valve and Discharge Tubing Installation 15 3 5 Air Release Valve Installation 16 4 Operation and Setting 17 4 1 Start Up and Priming 17 4 2 Setting 18 4 3 Signal Connector Description 27 4 4 Calibration 27 5 Maintenance and Repair 29 5 1 Maintenance 29 5 2 Diaphragm Replacement 30 5 3 Check Valves Rep...

Страница 4: ...ivered from the factory If your solution is not compatible with water disassemble the pump head assembly Thoroughly dry the pump head check valves seal rings valve balls and the diaphragm Reassemble head assembly and tighten the screws Refill the pump head with the solution before start the pump Tubing Connections Inlet and outlet tubing size must not be reduced Make certain that all tubing is sec...

Страница 5: ...pumping downhill or into low or no system pressure a back pressure anti syphon valve should be installed Contact your local distributor for further information Electrical Connections Warning To prevent the risk of electrical shock the metering pump must be plugged into a grounded power with ratings conforming to the data plate on the pump All wiring must confirm to local electrical codes If the pu...

Страница 6: ... solenoid diaphragm pump with changeable frequency It is capable for all kinds of solutions dosing including corrosive solutions It is widely used in petroleum chemical food pharmaceutical paper light industry agriculture water conservancy and other industrial and technological sectors in the process solution metering and dosing Solenoid metering pump is the use of electromagnetic push rod driven ...

Страница 7: ...d according to the pulse frequency selection switch It is a simple structure low energy consumption accurate measurement with a new screen display of electromagnetic diaphragm metering pump 2 2 Technical Parameter 2 2 1 General Parameter Metering Precision 2 in stable condition Allowable Ambient Temperature 10 45 Power AC 220V or AC110V Frequency 50Hz 60Hz Input Power Stroke Frequency Rated Power ...

Страница 8: ...Contact Load 5V 0 5mA 2 2 2 Performance Parameter Model Flow L H Pressure Bar Frequency Stroke min Caliber mm JLM S0110 1 0 10 110 5 JLM S0408 3 8 7 6 130 5 JLM S0607 6 3 6 8 160 5 JLM S0805 8 0 5 0 170 5 JLM S1204 12 4 0 150 5 JLM S1502 15 2 5 170 5 JLM S2001 20 1 0 180 5 2 2 3 Installation Drawing ...

Страница 9: ...tion Instruction Stop State Running State Setting State 1 Display Screen 2 Stop Start Button 3 Increase Button 4 Decrease Button 5 Power Cable 6 Signal Plug 0 MANUAL AUTO REMOTE SET FLOW 12 88L H 1999 9L 100 180 0 ...

Страница 10: ...7 2 4 Unpacking Check List Your carton will contain all or some of the following items Please notify the carrier immediately if there are any signs of damage to the pump or its parts ...

Страница 11: ...e pump is exposed directly to the sun a black UV shield should be installed The installation location of the metering pump should be convenient for personnel to access operate and maintain and do not have any obstructions in the work area If the shut off valve is closed at the discharge side of the metering pump when the shut off valve is closed the back pressure generated by the metering pump may...

Страница 12: ...1 Pump Installation To ensure safe operation of the metering pump tighten with bolts To ensure proper operation the metering pump inlet and outlet must be kept vertical during installation The pump has the following two installation methods A Flooded Suction ideal installation This method is installed by installing the pump on the base of the storage tank This installation is the most easy suitabl...

Страница 13: ...alve If it is transported downwards or transported to a low or low pressure place install a back pressure valve or an anti siphon valve All solutions can be used in this type of immersion but this is especially recommended for high concentrations of liquids ...

Страница 14: ...11 Note The following figure is typical wrong installation ...

Страница 15: ...12 B Suction Lift Tank Mount The pump is mounted on the top of the solution tank ...

Страница 16: ...13 Wall Bracket Mount The pump is mounted on the wall with bracket above the solution tank This method allows for easy changing of the solution tanks ...

Страница 17: ...n Tubing Installation The bottom valve acts as a check valve allowing the pump to self priming in the case of a suction installation The bottom valve must be dipped vertically into the bottom of the dosing medium If the medium contains a precipitate the bottom valve should be located approximately 50 mm from the bottom of the tank Ceramic weight can make foot valve and suction tube in vertical pos...

Страница 18: ...ect the other end of the tubing to the suction side of the pump head see tubing connection section 3 2 3 4 Injection Valve and Discharge Tubing Installation Injection valve prevents backflow Install the injection valve at the location where chemical is being injected into the system see tubing connection section 3 2 When installing the injection valve make sure that the valve is vertical to the bo...

Страница 19: ...se valve with exhaust sampling function The valve is mounted on the outlet check valve and is connected to the hose to allow the medium to return to the dosing tank In order to ensure smooth self absorption the tube can not be immersed in the medium ...

Страница 20: ...start priming the pump head Connect the power When the pump is running slowly increase the pulse frequency Suction tubing should begin to fill with solution from the tank A small amount of solution will begin to discharge out the discharge valve The pump is now primed The pump has a self priming function except for special conditions If the pump does not self prime remove the discharge check valve...

Страница 21: ...e press STOP START button to stop the pump Note Remote control mode does not work Setting Long press the STOP START button to enter the parameter set status In setting state press STOP START button for 3 seconds to exit the setting If there is no operation after 10 seconds automatically exit the setting mode 2 Button Description Stop Start Setting Increase Decrease STPO START ...

Страница 22: ... 4 RS485 control 0 1 0 OFF 1 ON 5 Control mode 0 3 0 Manual control 1 Pulse signal multiply 2 Pulse signal division 3 4 20mA signal 6 Pulse base 0 255 Base of pulse counts 7 Remote start stop 0 1 0 OFF 1 ON 8 Baud rate 0 2 0 9600 bps 1 19200 bps 2 38400 bps Setting Long press button to enter the setting state press button to enter the 0 8 cycle options 0 Machine Code 1 Set the minimum number of pu...

Страница 23: ...d must input the calibrated value in this setting 3 Set a fixed flow in percentage when start the pump After setting the value the pump will dose at this flow rate each time turning on the pump Change the value by button from 30 100 4 Open or close RS485 computer control 0 for OFF 1 for ON 5 Control mode press to adjust the mode 0 For Manual Control 1 For Pulse Signal Multiply 2 For Pulse Signal D...

Страница 24: ...alue receiving each pulse signal Under Pulse Signal Multiply model the pump will make one stroke after receiving the pulse signals of this value 7 Open or close the function of remote start stop the pump 0 for OFF 1for ON 8 Baud rate Value options as following 0 9600 bps 1 19200 bps 2 38400 bps Modbus Communication Memory Space Setting Convention HI register high byte LO register low byte ...

Страница 25: ...low Setting HI 0x0000 0x03e7 2113 0x0841 Flow Setting LO 2114 0x0842 RS485 Control HI 0x0000 OFF 0x0001 ON 2115 0x0843 RS485 Control LO 2116 0x0844 Percentage HI 0x0000 0x0064 2117 0x0845 Percentage LO 2118 0x0846 Running Mode HI 0x0000 0x0005 2119 0x0847 Running Mode LO 2120 0x0848 4 20mA Value HI 2121 0x0849 4 20mA Value LO 2122 0x084A Cumulative Flow HI Uint16 type 0 9496 7 The maximum value is...

Страница 26: ...0854 Pulse per Minute LO 2133 0x0855 Instant Flow HI 0x0000 0x03e7 2134 0x0856 Instant Flow LO 2135 0x0857 Running Mode HI 0x0000 0x0005 2136 0x0858 Running Mode LO 2137 0x0859 Percentage HI 0x0000 0x0064 2138 0x085A Percentage LO 2139 0x085B Machine Code HI 0x0001 0x00fe 2140 0x085C Machine Code LO 2141 0x085D Pulse Base HI 0x0000 0x00ff 2142 0x085E Pulse Base LO 2143 0x085F Remote Control HI 0x0...

Страница 27: ...gisters CRC Check 1 254 1 Byte 0x04 1 Byte 0x12 1 Byte 0x12 Byte 0x 2 Byte Slave error returned Machine Code Function Code Error Code CRC Check 1 254 1 Byte 0x84 1 Byte 0x01 Check does not pass or 0x03 Remote control OFF 1 Byte 0x 2 Byte Read a single parameter example read cumulative flow Host send format Machine Code Function Code Register First Address Number of Registers CRC Check 1 254 1 Byte...

Страница 28: ...te 0x01 Check does not pass 或 0x03 Remote control OFF 1 Byte 0x 2 Byte Function 2 Write a single register function 0x06 Example write switch status Host send format Machine Code Function Code Register First Address Register Value CRC Check 0 254 1 Byte 0x06 1 Byte 0x0851 2 Byte 0x0001 2 Byte 0x1BBB 2 Byte Slave return correctly Machine Code Function Code Register First Address Register Value CRC C...

Страница 29: ...er of Registers Bytes Setting Value CRC Check 1 254 1 Byte 0x10 1Byte 0x0851 2Byte 0x0005 2 Byte 0x0A 1 Byte 10Byte 0x 2Byte Slave return correctly Machine Code Function Code Register First Address Number of Registers CRC Check 1 254 1 Byte 0x10 1 Byte 0x0851 2 Byte 0x0005 2 Byte 0x 2 Byte Slave error returned Machine Code Function Code Error Code CRC Check 1 254 1 Byte 0x90 1 Byte 0x01 Check does...

Страница 30: ...ut of the pump is determined and the pump is calibrated to adjust the actual output flow Make sure the pump is primed and the discharge tubing and injection valve is installed as they would be in normal service including factors such as working pressure solution viscosity and suction lift Place the foot valve in a graduated container with a volume of 1000ml or more Start the pump until all the air...

Страница 31: ...f time 120 strokes minimum The longer the time period the more confident you can be of the results Stop the pump Record the time and the volume of the discharge medium calculate the flow rate If the output is too low or too great increase or decrease the speed accordingly ...

Страница 32: ...p s power supply is not turned on during maintenance The drainage pipe should be decompression before maintenance Discharge and wash the pump head cavity Use of corrosive liquid is prohibited If the metered medium is a hazardous or unknown liquid check the performance parameters of the metered liquid before servicing The pump head should be emptied and cleaned 5 1 Maintenance Metering pump mainten...

Страница 33: ...lothing face shield safety glasses and gloves in the process of replacement See also other protective measures on the Material Safety Data Sheet provided by the material supplier JLM S metering pump is designed for trouble free operation but in order to make the pump in the best working condition the elastic parts must be maintained daily It is recommended to replace parts such as diaphragm check ...

Страница 34: ...p head is rinsed remove the bottom valve from the liquid and continue running the pump to allow the air to enter until the pump head has no water or a neutral solution If the liquid can not be pumped due to diaphragm rupture remove the four bolts on the pump head and immerse the pump head in water or other neutral solution Stop the pump and disconnect the power unscrew the ...

Страница 35: ...the screw condition Turning out the diaphragm again Install the diaphragm base on the pump body the drain hole must be down Turning the diaphragm clockwise to the driving shaft until tightened Install pump head back to the pump body Take care of the check valves direction Diagonally tighten the bolts After 24 hours operation recheck the screws and tighten if necessary ...

Страница 36: ...t the pump and rinse the check valves When the check valves are rinsed remove the bottom valve from the liquid and continue running the pump to allow the air to enter until the discharge valve has no water or a neutral solution Disassemble the discharge check valve and place each part in correct order Disconnect the suction tubing from the suction valve Disassemble the suction check valve and plac...

Страница 37: ...use Power circuit Find the location of the circuit and handle it Wiring error Check the wiring diagram Pipeline pump cavity blockage Check the pipe pump cavity and check valves clean the dirt Wrong setting Check the setting No Output Pump not run Check power and setting Solution tank is empty Fill the solution tank Pipeline block Clean the pipeline Shut Off valve closed Open the valves The ball ch...

Страница 38: ...Diluting the viscosity or increase the pipe size Medium cavitation Increase the suction pressure reduce the suction lift Output gradual descend Check valve leakage Clean or change it Suction tubing leakage Find out the leakage point and handle it Strainer block Clean or change the strainer Medium change Check the viscosity Tank air vent hole is blocked Dredge vent hole Flow Unstable Suction tubing...

Страница 39: ...36 7 Main Parts List Pump Body ...

Страница 40: ...37 Pump Head ...

Страница 41: ...38 Valves ...

Страница 42: ...mp power supply range is 10 of the rated voltage for details please refer to the relevant technical information For areas where the supply voltage fluctuates or the surge voltage exceeds the allowable range please install an AC regulated power supply Equipment loss due to over voltage of power supply our company does not assume the responsibility of quality assurance Please read the manual careful...

Страница 43: ......

Страница 44: ...Technology Co LTD ADD No 227 Huishu Road Linhai Zhejiang China TEL 0086 576 85289780 FAX 0086 576 85668297 WEBSITE www ligaopumps com E MAIL sale2 ligaopumps com Version 3 0 Specifications subject to change without notice ...

Отзывы: