D+

H+

M+

MO

Mode AUTO

time schedule 1/16

set day

hour

minute

Sample schedule settings. Schedule 1, day: Wednesday, start of cleaning 16:00, end of cleaning: 21:00.

MO

WE

WE

23 / 24

22 / 24

LIFETECH s.r.o. 

LIFETECH s.r.o. 

Mode B-using schedule

Recommended schedule settings

It is recommended to set the timer on the first schedule so that the device turns on all days at 0:00. 

That means the ON time for MO-TU-WE-TH-FR-SA-SU will set at 0:00. OFF time should be set to the re

-

quired time to finish cleaning the area according to the relevant day or similarly MO-TU-WE-TH-FR-SA-

SU. The cleaning cycle then starts switching the main rocker switch to the (i) - (on) position. The produc

-

tion of ozone is then started without delay and it is necessary to leave the cleaned area immediately.

In order for the schedule to run, the mode must be set to AUTO! Switching on the timer 

is indicated by a red diode above the LCD. Each schedule must have a completed time to 

turn on and time to turn off!

1

Press

Set auto mode (responds to the set schedule).

2

Press

To set a schedule. You can set up to 16 schedules at unique time inter

-

vals.

3

Press

To switch the schedule. Each schedule contains an ON time and an OFF 

time.

4

Press

To set the day of the schedule (MO-Monday, TU-Tuesday, WE-Wednes

-

day, TH-Thursday, FR-Friday, SA-Saturday, SU - Sunday)

5

Press

To set the hours 00:00 - 24:00

6

Press

To set the minutes 00:00 - 00:59

7

Press

To set additional timelines. Repeat steps 3-6.

8

Press

To save and return to the main menu.

User manual

Содержание LifeOX-AIR Ultra 10 WT

Страница 1: ...N vod k pou it LifeOX AIR Ultra 5 10 20 WT N vod obsahuje d le it informace Je nutn aby se provozovatel s t mito informacemi detailn sezn mil je t p ed zprovozn n m za zen...

Страница 2: ...nky pou it Vzduch z m stnosti je ventil torem nas v n do za zen LifeOX AIR Ozzy Zde je v koronov m v boji st vzdu n ho kysl ku p em n na na ozon Zdrojem vysok ho nap t pro zap len v boje je vysoko nap...

Страница 3: ...tn pro elektrick za zen P edch zejte razu elek trick m proudem Nikdy se nepokou ejte vniknout do za zen nikdy ho sami neopravujte P i provozu nesm b t za zen zakryto a nesm b t p en eno Za zen nesm p...

Страница 4: ...en je ur eno pro pou it ve vnit n ch prostorech s minim ln pra nost Teplota prost ed 10 40 C Se zv en m teploty se sni uje innost chlazen p stroje a n sledn innost generace ozonu Vlhkost vzduchu do 60...

Страница 5: ...ven minut 00 00 00 59 A Manu ln Tento zp sob sp n n doporu ujeme zejm na pro p pad kdy je za zen neust le p en eno mezi m stnostmi a bylo by tak zbyte n pracn prov d t neust le p enastavov n asov ho p...

Страница 6: ...out Pro nastaven hodin v asov m pl nu 00 00 24 00 6 Stisknout Pro nastaven minut v asov m pl nu 00 00 00 59 7 Stisknout Pro nastaven dal ch asov ch pl n Postupujte opakovan dle kroku 3 6 8 Stisknout P...

Страница 7: ...ba o et en Objem m stnosti m3 10 10 50 50 100 100 200 200 340 LifeOX AIR Ultra 20 WT B n dezodorizace cigaretov kou 2 5 min 5 30 min 20 60 min 0 5 1 5 h 1 2 h Dezinfekce Likvidace pl sn odstran n chem...

Страница 8: ...s sucked into the Lifeox AIR Ultra device by a fan Here in the corona discharge part of the air oxygen is converted into ozone The source of high voltage for ignition of the discharge is a high voltag...

Страница 9: ...he safety precautions applicable to electrical equipment Avoid electric shock Never try to break into the device never repair it yourself During operation the device must not be covered and not be car...

Страница 10: ...ature 10 40 C With an increase of temperature the efficiency of device cooling decreases and consequently the efficiency of ozone generation as well Air humidity up to 60 RH Storage conditions 5 to 50...

Страница 11: ...I and the red diode on the timer must be lit at the same time D D Indication of the switched on device H H M M Timer Data Hour Minute Timer Reset Manual 1 Press and hold Enter the time settings 2 Pres...

Страница 12: ...osition The produc tion of ozone is then started without delay and it is necessary to leave the cleaned area immediately In order for the schedule to run the mode must be set to AUTO Switching on the...

Страница 13: ...mold destruction removal of chemical odour 1 h 1 5 h 5 8 h 8 12 h 12 14 h Model Estimated treatment time Volume of the room m3 10 10 50 50 100 100 200 200 340 LifeOX AIR Ultra 20 WT Conventional deodo...

Отзывы: