2 Collar-clips with screw for the
fle
xible tube (
fig
.1).
In order to iden
ti
fy these elements,
check the type plate and contact
your
g
as distributor.
A
fle
xible tube and a pressure
r
egul
ator must be used for the
conne
cti
on of this device. Contact
your
g
as distributor.
Working description
Dependin
g
on the model, your
space heater may be
fitt
ed with the
follow
ing
elements:
1 – Key to start-up,
lig
ht and select
the power of the device.
2 – Prote
cti
ve screen
g
uard.
3 – Blue
fl
ame burner.
4 – Pilot
lig
ht window.
5 – Back panel.
6 – Fi
tting
lu
g
s for back panel.
7 – Gas feed couplin
g.
8 – Wheels for transport.
Heater start-up
Once the space heater has been
taken out of its packa
ging:
Remove the back panel form the
device.
Connect the
fl
exible tube to the
g
as
inlet couplin
g
of the space heater
and to the r
egul
ator, ensur
ing
a
g
as
tigh
t
fi
t with the collar-clips well
screwed down. Avoid twis
ti
n
g
the
fle
xible tube.
Place the
g
as cylinder on the base
of the space heater and
fi
t the
r
egul
ator to the cylinder.
Aft
er
openin
g
the r
egul
ator, check that
there are no
g
as leaks by applyin
g
soapy water with a paintbrush to
the union of the
fl
exible tube with
the space heater and the re
gul
ator.
Fit the back panel usin
g
the
a
tt
ached
fi
xin
g
lug
s (
fig
.3).
CAUTION:
For their own safety,
keep the packa
ge
(cardboard,
Styrofoam, plas
ti
c ba
g
s, etc.) away
from your children.
Note:
the replacement of the
cylinder should be carried out in a
non-
fl
ammable environment.
The space heater includes a safety
device, which turns the device o
ff
an «d ex
ti
n
g
uishes the pilot
fl
ame
in the ven
ti
la
ti
on in the premises is
ins
uffi
cient or the concentra
ti
on of
CO2 exceeds the maximum
s
ti
pulated by law.
It is usual for this device to operate
in very small premises.
If the
fl
ame does
g
o out, ven
ti
late
the room well and wait a few
minutes before r
eign
i
ting
the
space heater.
Ignition instructions
A
tt
en
ti
on: before us
ing
the space
heater for the
fi
rst
ti
me and a
ft
er
lo
ng
periods of non-use, we
recommend switchin
g
on the
control bu
tt
ons several
ti
mes
alternately and without
g
as
fl
ow in
order to facilitate its opera
ti
on.
The space heater can be r
egul
ated
to three
diff
erent heat intensi
ti
es:
MAXIMUM,
MEDIUM
and
MINIMUM.
The
ig
ni
ti
on
mechanism is piezo-operated.
Open the
g
as outlet by rota
ting
the
lever on the r
egul
ator to the
correct posi
ti
on (
fig
.2).
Turning on the space heater
Press the bu
tt
on and rotate it to
your
left
, holdin
g
it down for 20
seconds. Repeat this procedure
several
ti
mes if necessary, un
ti
l the
pilot li
g
ht i
g
nites near the bo
tt
om
part od the prote
cti
ve screen
g
uard
(where the spark is seen),
fig
.4 and
keep press
ing
the bu
tt
on for 10
seconds. If, on releas
ing
the
bu
tt
on, the
fl
ame
g
oes out, please
repeat the whole procedure.
For MINIMUM heat – rotate the
bu
tt
on to
For MEDIUM heat – rotate the
bu
tt
on to
For MAXIMUM heat – rotate the
bu
tt
on to
Maintenance
If any anomaly is observed or spare
parts are required, contact our
Technical Service.
The periodical maintenance must
be carried out exclusively by an
authorized technician.
We would recommend that you
have a service carried out every
two years by an authorized
technician.
Watch the pilot
lig
ht, which should
be stable.
Check to see if it is necessary to
cha
ng
e the
fl
exible
g
as tube. If it
proves necessary, obtain a new
tube and connect it as explained in
“Heater start-up”.
It is recommended that the
cleanin
g
of the space heater be
carried out with the
g
as r
egul
ator
closed and the heater completely
cold, with nonabrasive products.
The user must wear prote
cti
ve
gl
oves to clean the heater.
When the space heater is not in
use, we recommend stori
ng
it in a
dust-free atmosphere, protected
with a cloth or plas
ti
c cover in a dry
place.
Warranty
All our space heaters have been
me
ti
culously checked before
leav
ing
the factory. Nevertheless, if
any
anomaly
is
observed
remember that our extensive
Technical Service network is at
your disposal. You should read the
sec
ti
on “Before callin
g
in Technical
3