CONTROL PANEL

4

CONTROL PANEL 2

1

REMOTE CONTROLLER SIGNAL RECEIVER

TEMP button

Press this button to adjust setting the temperature within the range of 63F/17C to 88F/31C. 

When in the TIMER mode (press and release the TIMER button to enter this status) use

TEMP + or - buttons to set the TIMER time range between 1-12 hours.

2

DIGITAL DISPLAYER

FAN Mode: Indicates room temperature.

COOL or DRY Mode: Indicates setting the temperature.

TIMER Operation: When pressing the TIMER button, this indicates timer time.

If the time has not been adjusted, after 5 seconds the temperature will appear.

ROOM TEMP SENSOR Failure: Display indicates temperature at 77F/25C.

 

7

POWER  button

To turn the air conditioner ON, press the button and the power indicator will light.

To  turn the air conditioner OFF,press the button again.

Press this button to set the air speed you desire: High/Low/Med.

UNIT INDICATION button

Allows you to choose between the operation modes: COOL, DRY, FAN, HEAT (heat for the
cooling and heating model).

5

8

MODE button

When selected the corresponding operation mode or fan speed, or the water full, the light will be

on.

6

FAN SPEED button

TIMER button

The TIMER has two modes Switch-ON and Switch-OFF.  If the unit is running, pressing the
timer button will enter you into the Switch-OFF mode.  If the unit is off, pressing the timer
button will enter you into Switch-ON mode.  Pressing this button again will cancel the timer
option.  To set the TIMER time use the + or - buttons accordingly. The time can be set
between 1-12 hours.

4

Note:

Features and appearance may vary depending on your air conditioner model.

3

Содержание LS-10PAC

Страница 1: ......

Страница 2: ...ontrol Water Drainage Maintenance Service Safety Troubleshooting Installation Warning 1 This appliance is not intended for use by children or invalid persons without supervision 2 The plug should be a...

Страница 3: ...IONER 1 Other air conditioning patterns are recommended when the ambient temperature is either below 18 0 C 65 0 F or above 35 0 C 95 0 F CAUTION Please read this instruction manual carefully to get o...

Страница 4: ...2 FRONT BACK PARTS Note Features and appearance may vary depending on your air conditioner model Handle Control knob Adjustable air fins Cold air outlet...

Страница 5: ...OOL the air conditioner will be in low cooling operation mode to delivery weak airflow MED COOL When the knob is turned to MED COOL the air conditioner will be in medium cooling operation mode to deli...

Страница 6: ...ss the button and the power indicator will light To turn the air conditioner OFF press the button again Press this button to set the air speed you desire High Low Med UNIT INDICATION button Allows you...

Страница 7: ...or unlock the keypad and prevent undesired changes to the room temperature and unit settings 10 Fan speed Press this button repeatedly to change the unit fan speed between high medium or low air outpu...

Страница 8: ...f the signal is transmitted from the remote to the air conditioner and there is no acknowledgement please replace the batteries 1 Remove the batteries by sliding the case cover open as the arrow indic...

Страница 9: ...o drain the water Power off then unplug the air conditioner disconnect the exhaust hose from the back and move the unit to a suitable drain location or outdoors Remove the base stopper from the base w...

Страница 10: ...ty through a hose not provided Of course this method will reduce the efficiency of the unit a Pulll out the partition plate stopper b Connecting the hose to partition plate joint and lead it to the fl...

Страница 11: ...stall the air filter back to its original place CLEANING OF AIR FILTER CLEANING OF AIR CONDITIONER PRIOR TO OPERATION SEASONS 1 Check to see if the air inlets and outlets of the unit are blocked 2 Che...

Страница 12: ...Do not use the unit in narrow rooms Avoid direct sunlight to the unit Do not use the unit in water or near water to avoid electrical shock Keep three feet around the unit to avoid overheating and elec...

Страница 13: ...the power source normal Is the air exhaust fixed rightly or be bended Did you add an air exhaust It is normal Push the plug into the wall socket Reset the circuit breaker or move it to the on position...

Страница 14: ...air conditioner in a flat location where the air outlets cannot be obstructed Make sure the unit has 3 ft around it for airflow Installation and Uninstallation of the Air Exhaust Hose See the figure...

Страница 15: ...rrows for direction Then detach the air exhaust hose into the air conditioner Installation See the figure below Attach the air exhaust adapter into the air exhaust hose Use the arrows for direction Th...

Страница 16: ...se modify some aspects of the installation procedures for certain types of windows See the figure below 14 See the figure below install the air exhaust adapter to window kit Window slider kit Minimum...

Страница 17: ...be at least 50 cm away from the exhaust air intake 3 Keep the smoothness of the whole air exhaust hose especially in the bending points Avoid any abrupt steep angled bendings 15 Interchangable Air Out...

Страница 18: ...16...

Страница 19: ......

Отзывы: