Notes and Warnings

Symbol Definitions

The following symbols are used throughout this manual

h

 

This symbol is intended to alert the installer of shock 

hazards within the enclosure . Service should only be 

performed by qualified service personnel

i

 

This symbol is intended to alert the installer of im-

portant information intended to help the installer 

avoid personal injury or property damage

Warnings

h

 

Installation and service should be performed only by 

qualified service personnel and should conform to 

all local codes

h

 

To reduce the risk of electric shock or fire, do not 

expose this equipment to rain or moisture

i

 

This equipment shall be installed in a manner which 

prevents unintentional operation by employees, 

cleaning personnel, or others working in the prem-

ises, by falling objects, customers, building vibra-

tion, or similar causes

i

 

This equipment is not intended for use within the pa-

tient care areas of a Health Care Facility

h

 

Replace fuses only with the same type and rating as 

indicated in the specifications section of this manual .

i

 

To prevent impaired operation, ensure that all wiring 

is routed and secured to prevent accidental open or 

short circuit conditions

i

 

The system and any batteries (if used) should be 

tested at least once per year to ensure proper opera-

tion

Regulatory Information

The equipment discussed within this manual has been test-

ed to the following standards:

•  EN60950  EN55022 CLASS A  EN55024
•  CSA C22 .2 #60950
•  CE

FCC Information
NOTE:

 This equipment has been tested and found to comply 

with the limits for a Class A digital device, pursuant to Part 

15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference when 

the equipment is operated in a commercial environment. 

This equipment generates, uses, and can radiate radio fre-

quency energy and, if not installed and used in accordance 

with the instruction manual, may cause harmful interfer-

ence to radio communications. Operation of this equipment 

in a residential area is likely to cause harmful interference in 

which case the user will be required to correct the interfer-

ence at his own expense.

Conventions Used Within this Manual

Positional information (e .g . top, bottom, up, down, left, 

right, etc .) is referenced with the board or enclosure in the 

orientation shown in the illustrations in this manual

Содержание NETPOWER NPR250-16M

Страница 1: ...LifeSafety Power Inc PH 888 577 2898 TechSupport LifeSafetyPower com NETPOWER m a n a g e d m u l t i p o r t p o e m i d s p a n i n j e c t o r s NPR Installation Manual P03 034 Rev A05...

Страница 2: ...first time 4 2 3 Configuring the TCP IP Settings 6 2 4 Configuring the Administration Settings 7 2 5 Configuring the SNMP Settings 7 2 6 Configuring the Email Settings 8 2 7 The Programming Page 9 2...

Страница 3: ...red operation ensure that all wiring is routed and secured to prevent accidental open or short circuit conditions iThe system and any batteries if used should be tested at least once per year to ensur...

Страница 4: ...mable port priority NPR250 8M 8 port 32W per port 270W total Managed midspan injector Standard battery charger Programmable port priority The illustration below shows the model numbering conven tion o...

Страница 5: ...open 1U location in the rack 4 Center the enclosure in the rack and secure with the four 10 32 x 3 4 screws provided NOTE Use rails or other appropriate support for heavy enclosures Keep heavier comp...

Страница 6: ...erview NETPOWER On Off External DC h No user serviceable parts inside refer servicing to qualified service personnel Aucune pi ce interne ne peut tre r parer Demandez l assistance d un technicien qual...

Страница 7: ...LED Status Status Green Normal Operation Yellow Fault No Powered Device connected or fault condition present Off Port disabled When the NPR is first powered these LEDs will light yellow in sequence 1...

Страница 8: ...ttings IP Address 192 168 1 9 Username admin Password admin Open a browser on the computer and enter 192 168 1 9 into the address bar not in a search bar you may need to disable a search from the addr...

Страница 9: ...5 Installation and Operation Figure 7 PowerComPoE opening HOME page...

Страница 10: ...name and default password will be reset to factory default values Net Mask Should typically be set to 255 255 255 0 MAC address The MAC Address is factory set and is not programmable by the user Gate...

Страница 11: ...rt 161 Be sure to open the SNMP port if accessing SNMP outside your firewall Click the Submit button at the bottom of the Basic section to save the settings otherwise you will lose the settings These...

Страница 12: ...e proper authentication method for your email provider from the drop down list Usually this is login Send Period Selects how often the NPR sends a regular email status report The period can vary from...

Страница 13: ...includes an attached CSV file containing all of the data in the HOME page NOTE The email settings must be configured properly See Section 2 6 of this manual To enable upper and lower limit checking ch...

Страница 14: ...must be performed in order to con nect the device to the MSM 200 NOTE To configure an NPR which is NOT on the same LAN as the MSM 200 both the MSM 200 and the NPR must be on networks with inter net a...

Страница 15: ...11 Installation and Operation PAGE INTENTIONALLY LEFT BLANK...

Страница 16: ...n the Configure page The date and time can be adjusted by time zone and is battery backed up via an internal battery Auto refresh Click the Enable button to turn on auto refresh for the home page Auto...

Страница 17: ...ections of this manual for more information Voltage This column displays the measured PoE port output volt age for each port in volts Current This column displays the measured PoE port output cur rent...

Страница 18: ...burned to the processor in the NPR Verify the cor rect file name and click the Confirm button to confirm the upgrade Next click the Burn button to begin burning the firmware to the NPR s processor Thi...

Страница 19: ...or otherwise at tempt to derive any of the Software s source code d No Distribution No Modification No Derivative Works Recipient shall not network rent lend loan distribute or create derivative work...

Страница 20: ...ive any of the Software s source code d No Distribution No Modification No Derivative Works Recipient shall not network rent lend loan distribute or create derivative works based upon the Software in...

Страница 21: ...ASSIGNS IS ARE ADVISED IN ADVANCE OF THE POSSIBILITY OF THE DAMAGES IN QUESTION AND EVEN IF SUCH DAM AGES WERE FORESEEABLE AND D EVEN IF RECIPIENT S REMEDIES FAIL OF THEIR ESSENTIAL PURPOSE If applic...

Страница 22: ...ts distributors be liable for any incidental indirect or consequential damages arising from the sale resale use or misuse of the product Specifications are subject to change without notice In addition...

Отзывы: