background image

FlexPower AC Power System Installation Manual

iv

1

Quick Install Guide

Enclosure-Level Products

Mounting an enclosure to a wall is via the two recessed 

keyholes and two recessed mounting holes in the back of 

the enclosure.

1.  (Optional) Remove the enclosure’s cover.
2.  Locate the top keyhole mounting holes in the back of the 

enclosure.

3.  Mark and pre-drill the locations for the keyholes in the 

mounting surface.

4.  Partially install two fasteners appropriate for the sur-

face on which the enclosure is being installed. Leave the 

heads of the fasteners approximately ¼" out from the 

surface. Minimum fastener size should be #10 or larger.

5.  Hang the enclosure on the two fasteners and mark the 

locations of the two bottom mounting holes.

6.  Remove the enclosure and pre-drill the locations for the 

two bottom mounting holes.

7.  Re-hang the enclosure on the top mounting fasteners, 

start the bottom two fasteners and tighten all fasteners.

8.  Reinstall the enclosure’s cover, if removed in step 1.

i   

It is the installer’s responsibility to determine the ap-

propriate fastening system for use with the surface to 

which the enclosure is being mounted.

Section 1 - Installation and Operation

1 .1  Mounting

Содержание FlexPower

Страница 1: ...LifeSafety Power Inc PH 888 577 2898 TechSupport LifeSafetyPower com P03 003 Rev A09 AC Power System Installation Manual FlexPower...

Страница 2: ...tandoffs and pluggable wires to add additional system capability or capacity when needed Reliability All power supplies within the FlexPower system are fully fault protected and feature conformal coat...

Страница 3: ...nts unintentional operation by employees cleaning personel or others working in the premesis by falling objects customers building vibration or similar causes i This equipment is not intended for use...

Страница 4: ...ation and Operation 1 1 1 Mounting 1 1 2 Connections and Setup 2 1 2 1 Transformer Secondary Wire Colors 3 1 3 Typical Installation Wire Routing 4 1 4 Power Up and Basic System Verification Checklist...

Страница 5: ...Leave the heads of the fasteners approximately out from the surface Minimum fastener size should be 10 or larger 5 Hang the enclosure on the two fasteners and mark the locations of the two bottom mou...

Страница 6: ...voltage buss input is selected for the out put Jumper numbers correspond with the zone number eg JP1 is the jumper for OUT1 Possible settings are as follows Position 2 Left 28VAC 18V for 16 5 18V FPA...

Страница 7: ...4 17A 28V 3 57A FPA150A 0V 24V 6 25A 28V 5 4A FPA300A 0V 24V 12 5A 28V 10 7A Brown Common Voltage Current Voltage Current FPA200A 0V 16 5V 6 06 18V 5 56A Black Common Voltage Current Voltage Current 0...

Страница 8: ...outs AC Input Power must enter the enclosure via one of the 3 4 single knockouts The installation and all wiring methods shall be in ac cordance with ANSI NFPA70 and all local codes For Canadian Insta...

Страница 9: ...PA power supply Q 3 Ensure all green Zone LEDs are lit Q 4 Verify zone output voltage with a meter a If the zone s jumper is set in position 1 the voltage should be approximately 24VAC b If the zone s...

Страница 10: ...jumpers and fuses are in place and intact Contact Life Safety Power Incorrect voltage out of zone Zone jumper set incorrectly Verify the proper setting of the zone jumper AC Input voltage incorrect V...

Страница 11: ...th A8P 2 5A zone max Fuse Ratings A8 ATM 3A ATM 3A ATM 3A ATM 3A ATM 3A ATM 3A A8P N A N A N A N A N A N A BTU Output BTU 68 102 204 410 612 137 3 2 Temperature Specifications All Models Ambient Tempe...

Страница 12: ...tability of each product for their particular application LifeSafety Power makes no warranties as to the accuracy or completeness of the information and disclaims any liability regarding its use LifeS...

Отзывы: