background image

6

1.2

Setup

Read the Operation Manual before setting up the Inclusive Recumbent Lifecycle

®

Exercise Bike.

Electrical Power Requirements

An optional external power supply is available for the Inclusive Recumbent Lifecycle Exercise Bike. The external power
supply requires an AC power supply according to the electrical configurations listed in the chart below. 

NOTE: 

Do not modify the plug provided with this product. If the plug does not fit into an available electrical outlet, have a prop-

er outlet installed by a qualified electrician.

Where to place the Inclusive Recumbent Lifecycle Exercise Bike

Following all safety instructions in Section 1.1, move the bike to the location in which it will be used. See Section 3, titled

Specifications,

for the dimensions of the product footprint (assembled dimensions). Allow a distance of 21 to 30 centime-

ters ( 8 to 12 inches) between the bike and other objects or surfaces on either side. Allow a distance of 1 meter ( 3 feet )
from the front or rear of the bike to any other object or surface.

How to stabilize the Inclusive Recumbent Lifecycle Exercise Bike

After placing the bike in position, check the unit’s stability by attempting to rock it from side to side. Any slight rocking
indicates that the unit must be leveled. Determine which foot is not resting completely on the floor. Loosen the jam nut
(A) with an open-end M17 wrench, and rotate the stabilizing foot (B) to lower it. Verify that the bike is stable, and repeat
the adjustment as necessary until the unit no longer rocks. Lock the adjustment by tightening the jam nut against the
stabilizer bar. 

Check for Battery power

The Inclusive Recumbent Lifecycle Exercise Bike console is powered by a rechargeable 6-volt battery. Check the battery
by pressing and holding the power on/off       key. The console should beep and light up. The Message Center on the
console will display a prompt to set up a workout. If a prompt doesn’t appear or initializing doesn’t begin, mount the
Inclusive Recumbent Lifecycle Bike and begin pedaling. The console should light up and programming a workout can
begin. Pedal for 20 minutes at 40 RPM or faster during a workout to charge the battery. The pedal action during work-
outs keeps the battery charged. If the Inclusive Recumbent Lifecycle Exercise Bike is powered by the external 36V DC
power supply, battery maintenance is automatic and pedaling is not required. 

Supply Voltage

(VAC)

100

110

120

200

220

230

240

Frequency

(Hz)

50 / 60

50 / 60

50 / 60

50 / 60

50 / 60

50 / 60

50 / 60

Rated Current

(Amps)

1.6

1.6

1.6

.8

.8

.8

.8

Содержание 95R

Страница 1: ...95R Inclusive Recumbent Lifecycle Exercise Bike Base Owners Manual 05 21 10 M051 00K66 B147 inclusive fitness accredited item 2007 2012...

Страница 2: ...m Operating Hours 9 00h 17 00h MEZ Spain Life Fitness IBERIA C Frederic Mompou 5 1 1 08960 Sant Just Desvern Barcelona SPAIN Telephone 34 93 672 4660 Fax 34 93 672 4670 Service Email info iberia lifef...

Страница 3: ...quickly and in instructing others on how to use it correctly and safely Class I Inclusive Professional and or commercial use CAUTION Any changes or modifications to this equipment could void the prod...

Страница 4: ...pulseTM System Sensors 12 2 5 Recycling the Battery 12 2 6 How to Obtain Product Service 12 3 Specifications 13 3 1 95R Inclusive Recumbent Lifecycle Exercise Bike Base 13 2010 Life Fitness a division...

Страница 5: ...vels of resistance CAUTION Health related injuries may result from incorrect or excessive use of exercise equipment Life Fitness STRONGLY recommends seeing a physician for a complete medical exam befo...

Страница 6: ...trieve it If the item cannot be reached contact Life Fitness Customer Support Services Never place liquids of any type directly on the unit except in the accessory tray water bottle holder Containers...

Страница 7: ...tempting to rock it from side to side Any slight rocking indicates that the unit must be leveled Determine which foot is not resting completely on the floor Loosen the jam nut A with an open end M17 w...

Страница 8: ...nt Lifecycle Exercise Bike is no exception If the seat is too close excessive strain will be placed on the knees and quadriceps muscles if the seat is too far the resulting reaching action will irrita...

Страница 9: ...the tightness of the straps The Velcro type safety straps on the pedals of the Inclusive Recumbent Lifecycle Exercise Bike can be adjusted to fit a variety of shoe sizes Pull the D ring H upward to se...

Страница 10: ...p your Inclusive Recumbent Lifecycle Exercise Bike operating at peak performance Locate the Inclusive Recumbent Lifecycle Exercise Bike in a cool dry place Keep the pedal straps fastened securely when...

Страница 11: ...equipment fans two way radios and high voltage highcurrent power lines Heart rate readings are abnormally elevated Television sets and or antennas generate electromag netic interference Move the trea...

Страница 12: ...ot within 3 feet 1 meter of the heart rate receiver Make sure the chest strap trans mitter is within 3 feet 1 meter of the heart rate receiver Polar telemetry heart rate chest strap battery is deplete...

Страница 13: ...remove the two screws that hold the end cap shroud to the back of the bike To remove the battery remove the two wires connected to the battery and the two screws that hold the battery in place Dispose...

Страница 14: ...hes Pedal speed range 40 RPM 120 RPM Drive type Alternator Belt Accessory Tray Standard Integrated Reading Rack Standard Color Silver with gray and yellow accents PHYSICAL DIMENSIONS Length 165 centim...

Отзывы: