INDEX
1.0 TECHNICAL DATA
1
2.0 INSTALLATION
2
2.1
Use limits
2
2.2
Standard installation
2
2.3
Rear & front bracket position
3
2.4
Operator position and limit switches adjustment
4
2.5
Operator unlocking
6
3.0 LINKAGES & CONNECTIONS
7
3.1
Operator electrical connections
7
3.2
Unit board operator
7
4.0 GENERAL INFORMATION, PRODUCER DATA, SPECIFIC USE
8
5.0 PRESCRIPTIONS & SAFETY WARNING
8
6.0 MAINTENANCE
9
7.0 DEMOLITION & RECYCLING
10
8.0 DECLARATION OF CONFORMITY
10
OP2
Irreversibile mechanical 24V operator for swinging gates, with mechanical
stops
OP224 UNI
OP224 INI
Main power supply
V 230 Vac 50 Hz
LIFE electronic unit power supply
V 24 Vdc
LIFE electronic board: GE UNI 24R
Yes Yes
(1 motor) (2 motors)
max power
W 40 40+40
max input
A 3 3+3
Input current to line (230V) 1,1 1,5
Push
N 1500
Lubrification Type Permanent grease
Limit switches
2 (mechanical)
Reduction ratio
1/672
Max. rod run
Mm 350
Operating temperature °C da -20 a +70
Protection level
IP 44
90° opening time
S 18
Intermittence
% 80
Nominal time work
min. 20
Motor isolation class
D
Battery recharge time*
h 48
Operator weight
kg 3,7
Dimensions mm 90x755x110
Use in acid, salt or potential esplosive atmosphere
no
Max. leaf span & weight
2 m - 200 kg
ENGLISH
1
1.0 TECHNICAL DATA
LIFE h�
functionality.
* for 2 Ah battery (optional & installed within the control board).
2MANUALE (INGLESE) Life.indd 1
30-10-2008 15:16:55