8
1 WIRING AND CONNECTIONS
•
Before commencing wiring and connection work, read the SAFETY INSTRUCTIONS AND WARNINGS and INSTALLATION INSTRUCTIONS
AND WARNINGS chaps carefully.
•
All wiring and connection operations must be carried out with the control unit disconnected from the electricity supply. If the disconnection
device is not in view, display a sign reading: “ATTENTION: MAINTENANCE WORK IN PROGRESS”.
1.1
Control unit connections
Terminals
Description (SEE WIRING DIAGRAM on page 2A)
AERIAL
: aerial sheath input
Use a RG58- 50ohm cable.
AERIAL
: aerial cable input
1
2
6
6 - 8
6 - 7
COMMAND AND PHOTOCELL COMMON
: for stop, open, close, step, photo and +12V inputs.
OPEN
: NO input, commands gate opening.
16 - 15
USCITA 24 Vac:
per alimentazione di vari dispositivi, 200 mA max.
19
FLASHING OR COURTESY LIGHT POWER SUPPLY COMMON
16
COMMON, INDICATOR LIGHT, 24 V ac OUTPUT
6 - 9
CLOSE
: NO input, commands gate closure.
STOP
: programmable NC input, commands gate stoppage.
Can be connected to safety devices such as an emergency stop button.
When the command is released automatic closure never occurs and a new movement command must be given.
Leave jumpered if no device is envisaged.
6 - 11
PHOTO1:
programmable NC input for photocells or safety devices. Causes gate stoppage during both opening and closure.
Motion resumes during opening when the photocell or safety device is disengaged.
Leave jumpered if no device is envisaged.
6 - 12
PHOTO:
NC input for photocells or safety devices. Does not intervene during gate opening; during closure causes reversal of gate
motion until open.
Leave jumpered if no device is envisaged.
19 - 17
FLASHING LIGHT
: 230 Vdc 25W max output for connecting a SPLENDOR SRL flashing light characterised by three flashing modes:
1) slow during door opening; 2) fast (flashing times halved) during closure. 3) three flashes and a pause to indicate a fault state or
travel identification.
COURTESY LIGHT
: 230 Vdc 40W max. output for connecting a courtesy light that switches on at the start of each movement (opening
or closure and is characterised by an fix for 30 sec.)
16 - 14
INDICATOR LIGHT:
24Vac 3W max output, for connecting an indicator light that copies the function of the flashing light during movement
and that remains on when the gate is open.
19 - 18
6 - 10
STEP
: NO input, commands gate movement according to the following cycles:
SEMI-AUTOMATIC MODE: Open, stop, close, stop.
Automatic mode: open, pause, close, pause.
230Vac 50 Hz power supply
L 2
L 1
N.C. = normally closed contact – NO = normally open contact
Terminals
Description
BLACK CABLE
COMMON ELECTRONIC AND AUXILIARY POWER SUPPLY
GEAR MOTOR RELEASE SWITCH
0
BLACK CABLE
-
RED CABLE
DARK BLUE
GREEN
STOP PLATE and ENCODER
TRANSFORMER POWER SUPPLY
+
BLACK
A
B
C
D
E
16
CLOCKWISE ROTATION
COMMON
BROWN CABLE
BLUE CABLE
ANTI-CLOCKWISE ROTATION
CAPACITOR
230Vac MOTOR OUTPUT
WHITE CABLE
24
B1
ORANGE CABLE
COMMON
FC1
FC2
Содержание RG1R DL S SUPRA MB 230 Vac
Страница 3: ...3 2 4 3 X2 X2 1 180 1 2 1 Dismantling of the barrier 2 Manual release ATTENTION ...
Страница 4: ...4 1 2 3 4 5 3 Fixing on the ground with base sole SUE 1 optional ...
Страница 7: ...7 mm 8 X4 A A B RIGHT LEFT 5 Assembly boom barrier 6 Mechanical stops adjustment ...
Страница 18: ...18 1 2 7 Ricambi ...