7. Cable Handling Guide
Cable Terminations, Tensioning and Wear Guide
Cable Connections with threaded cable ends are required to be installed and maintained following the specifications
identified below. Failure to follow these specifications can lead to the dislocation of the threaded cable during use and
can cause serious injury. Along with securing the threaded cable end and jam nut, it is important to check the entire
unit and ensure that all hardware is securely fastened and not left loose upon completion of cable installation.
WARNING: Use of non certified “techs” note: Service warranties may be void if a non-
Life Fitness
-certified
technician performs service work. Replacement of any strength cables should be performed by a
Life Fitness
certified technician.
Cable Terminations
1.
Cable must be threaded at least ½ inch (12.7mm) into termination points; at headplate (A) and frame/carriage (B).
2.
Certain models are now equipped with a bayonet portal to assist checking proper thread engagement. To do so,
attempt to pass a 7mm Allen wrench through the portal, if it goes through, more threads are needed to meet the
minimum requirement.
3.
When proper thread engagement is reached, tighten jam nut to 20-25 FT-LBS (27.2 - 34.0 Nm) using a 24mm
wrench.
Page 41 of 48
Содержание SYN90-CC
Страница 2: ......
Страница 10: ...Step Up Maximum Capacity Bolt to Floor Required Power Pivot Pinch Hazard Page 8 of 48 ...
Страница 11: ...Serial Number Label Locations Item Description Qty 1 Serial Number Label 1 Page 9 of 48 ...
Страница 24: ...Cable Routing Page 22 of 48 ...
Страница 50: ...Foot Dimensions Use below images to determine foot height thickness per strength family Page 48 of 48 ...
Страница 51: ......
Страница 52: ......