![Lifan Energy Storm PD20REG-DB Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/lifan/energy-storm-pd20reg-db/energy-storm-pd20reg-db_owners-manual_1907722024.webp)
Lifan Power USA. 2250 Industrial Park Rd. Van Buren, AR 72956
PH 866-471-7464 www.lifanpowerusa.com
23
12. Shutting down the generator
Should a need occur to shut down the generator, shut down the electrical output first by
turning the circuit breaker to the “OFF” position and depress the reset key. This will
automatically shut the engine and generator down.
The power switch (#2) needs to be in the open or on position if connected to the
ATS system in order for the unit to start automatically.
Chapter three: Long term care and storage of
Generator
Ⅰ
. Long term storage and care
1. Remove battery positive lead first and then negative lead. Remove battery and store in
dark dry place. It is recommended to recharge it slowly every three months.
2. Turn Gas line to generator in off position and disconnect. Plug gas line with rubber
plug to prevent dirt from getting into gas line.
3. Remove all dirt from the generator if long time storage is needed.
4. Drain coolant from engine. Place drain pan under pre plumed coolant line and open
valve allowing all coolant to drain (See page 26).
5. Drain oil from engine. Place drain pan under pre plumed oil line and open valve
allowing all oil to drain (See page 26).
6. Ensure engine is in good technical condition, keep all surfaces clean.
7. Remove all spark plugs, pour 1oz or 30grams of engine oil in each sparkplug opening,
turn crankshaft 20 turns slowly to allow oil to coat inside of cylinders and pistons, and
then reinstall spark plugs.
8. Use dewatering Vaseline (heat range 100°-200°F) wipe on the surface of contacts.
9. Add light amount of penetrant oil to all, hinges, bolts and moving parts.
10. Use clean canvas or cloth to cover the engine and keep it dust-free.
11. Store and cover in a warm clean room with temperatures above (5°C, 41°F) relative
humidity should be kept between 40-70%.
12. Check all loose nuts, bolts and screws.
13. Seal gas line inlet valve with rubber plug to keep gas line free of dust.
14. Push the emergency stop button.
15. Cover the generator with the dustproof cover, and keep it in the dry and clean place;
16. Keep it in well ventilated, dry rainproof area and away from flammable and explosive
materials