IF   THE   ENGINE   WILL   NOT   START:   

1.

 

Check   to   ensure   switches   are   in   the   “ON”   position.         

2.

 

Check   engine   oil   level.      The   unit   possesses   a   Low   Oil   Shutdown   feature   that   will   

not   allow   your   engine   to   start   if   the   oil   is   below   safe   operating   levels.      This   

feature   is   installed   to   increase   the   life   of   your   engine   and   prevent   engine   

damage.      If   oil   level   is   low,   fill   to   the   full   mark   on   dipstick.      Refer   to   the   Pre-­‐

Operating   Instructions:   Engine   Oil   Check   section   for   exact   oil   type   and   amounts.   

3.

 

Check   the   fuel   level   to   insure   adequate   fuel.      Add   fuel   if   necessary.   

4.

 

Remove   and   inspect   the   spark   plug   for   cleanliness   and   proper   electrode   gap.      If   

needed,   clean   or   replace   the   spark   plug.      Refer   to   Spark   Plug   Maintenance   in   the   

Maintenance   section   of   the   Owner’s   Manual   for   proper   procedure.   

5.

 

If   the   unit   will   still   NOT   start   after   performing   the   above   checks,   call   our   

customer   hotline   at   LIFAN   Power   USA   Toll   Free   1-­‐866-­‐471-­‐7464   or   take   the   unit   

to   an   authorized   Service   Center.   

NOTE:

      Periodically   on   the   initial   start-­‐up   or   after   the   unit   has   been   stored   

for   a   long   period   of   time,   the   float   for   your   “Low   Oil   Shutdown”   system   will   

stick   to   the   bottom   of   the   oil   pan.      Locate   the   two   (2)   wires   to   the   Low   Oil   

Sensor   Diode   (figure   “Low   Oil   Sensor   Diode”   to   the   right)   located   on   the   

side   of   the   engine   block.      Unplug   these   wires   and,   

only   after   ensuring   the   

engine   is   full   of   oil,

   start   the   engine   and   allow   to   run   until   warm   (normally   

20   minutes,   as   this   will   heat   the   oil   and   release   the   float   on   the   Low   Oil   

Shutdown   System).      Then   re-­‐plug   the   wires   to   the   terminals   on   the   Low   Oil   

Shutdown   Sending   Unit.   

   

IF   THE   WATER   PUMP   WILL   NOT   PUMP:

   

1.

 

Check   if   there   is   ample   water   in   the   pump   chamber   to   fully   prime   the   pump.   

2.

 

Check   if   the   filter   is   clogged   on   the   suction   hose.   

3.

 

Check   if   the   hose   clamp   is   securely   tightened.   

4.

 

Check   if   the   water   hose   is   damaged.   

5.

 

Check   is   suction   height   required   for   the   application   is   too   high.      Refer   to   Product   

Specifications   section   for   unit   maximum   suction   height.   

6.

 

If   the   water   pump   still   will   not   pump   water,   call   our   customer   hotline   at   LIFAN   

Power   USA   Toll   Free   1-­‐866-­‐471-­‐7464   or   take   the   unit   to   an   authorized   Service   

Center.   

   

   

Содержание LF1.5WP

Страница 1: ...1 5 WA T E RP U MP P UMPP RO O WN E R SMA N U A L...

Страница 2: ...rating Instructions and Owner s Manual LF1 5WP and LF1 5WP CA PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING YOUR NEW LIFAN Power USA Water Pump CA Indicates this unit is CARB Certified for Califo...

Страница 3: ...re where purchased Follow the procedures as outlined in the WARRANTY POLICY and WARRANTY REGISTRATION in the Owner s Manual For any questions visit www lifanpowerusa com or call 1 866 471 7464 3 Read...

Страница 4: ...structions 6 PRE OPERATING INSTRUCTIONS 9 Connecting Water Inlet Hose 9 Connecting Water Outlet Hose 10 Engine Oil Level Check 11 Engine Fuel Level Check 12 Air Cleaner Element Check 13 Pump Water Cap...

Страница 5: ...ior to operation Keep this Owner s Manual for assistance in the future such as proper maintenance schedules and tips to prolong the life and effective use of your unit If you require assistance please...

Страница 6: ...Recoil Fuel Tank Capacity 0 374Gallon Run Time 2 54hrs Fuel Type 874Octane4Gasoline Oil Type Amount SAE410w30w44124oz Low Oil Shutoff Protection Yes CARB Certified CA 4Models4Only Length 15in 38 1cm...

Страница 7: ...t if not avoided could result in death or serious injury Hazard Symbols and Meanings WARNING Running water pump emits carbon monoxide an odorless colorless poison gas Breathing carbon monoxide can cau...

Страница 8: ...f position Repair water pump with the fuel tank empty or the fuel valve in the off position Disconnect spark plug wire before transport or service WHEN STORING FUEL OR EQUIPMENT CONTAINING FUEL Store...

Страница 9: ...rnia Public resources code WARNING Unintentional sparking can result in fire or electrical shock WHEN TESTING FOR ENGINE SPARK Do NOT check for spark with the spark plug removed Use approved spark plu...

Страница 10: ...face Suction time varies with the length of the water inlet hose The filter matching with the water pump should be mounted to the end of the water inlet hose with a hose clamp as shown in the diagram...

Страница 11: ...t Hose Use commercially available hose hose joint and clamp A short hose with a big diameter will provide the best performance A long hose with a small diameter will increase flowing resistance and de...

Страница 12: ...art to the right in accordance with you regional environmental temperature Engine Oil Alarm System The engine oil alarm system aides in avoiding engine damage due improper amounts of engine oil in the...

Страница 13: ...ine is spilled wipe completely dry before starting the engine Avoid repeated or sustained breathing of gasoline fumes Avoid skin contact with gasoline Keep our of reach of children and pets Do NOT use...

Страница 14: ...of the engine To Check Air Cleaner Element 1 Remove the clip item 9 in Air Cleaner A below or the wing nut item 7 in Air Cleaner B below to remove and check the air filter element 2 For Sponge Type Ai...

Страница 15: ...ter inside the pump will cause the pump to overheat Prolonged operation of engine without water inside the pump will damage the pump gasket and impeller If water within the pump is not full shut off t...

Страница 16: ...move excessive dirt and or debris from the unit 2 Check Suction and Discharge Hoses a Inspect general condition of hoses to ensure hoses are in serviceable condition i Suction Hose must be reinforced...

Страница 17: ...recoil starting handle lightly until resistance is felt then pull briskly Do NOT allow the starter handle to snap back against the engine Return it gently to prevent damage to the starter 7 Once the e...

Страница 18: ...ORMAL PROCEDURE 1 Move the throttle valve lever to the SLOW position 2 Turn the engine switch to the OFF position 3 Turn the fuel cock to the OFF position 4 Remove the water drain plug and drain the p...

Страница 19: ...ailure to do so may result in damage to impeller ii After washing remove water drain plug and empty the water in the water pump completely iii Reinstall the water drain plug Before long term storage o...

Страница 20: ...ting and Storing the Unit continued 9 Add the recommended amount of fuel stabilizer in accordance with the amount recommended by the manufacturer of the fuel stabilizer to the unused gasoline left in...

Страница 21: ...prior to each use 1 Start your engine and let it warm up to get the oil warm and thinner Remove the dipstick by turning counter clockwise Remove the oil drain plug located below the dipstick utilizing...

Страница 22: ...R CLEANER MAINTENANCE 1 Remove the clip item 9 in Air Cleaner A below or the wing nut item 7 in Air Cleaner B below to remove and check the air filter element 2 For Sponge Type Air Filters wash with s...

Страница 23: ...can get sediment or trash in your Carburetor Bowl Use the following procedures to clean 1 Turn the fuel cock valve to the OFF Position 2 Remove the carburetor bowl by removing the mounting bolt locate...

Страница 24: ...altitude carburetor main spray nozzle and re adjust the adjusting screw for idle speed For usage in regions with an altitude of over 4 527ft 1380m contact your dealer to replace the standard carbureto...

Страница 25: ...7464 or take the unit to an authorized Service Center NOTE Periodically on the initial start up or after the unit has been stored for a long period of time the float for your Low Oil Shutdown system w...

Страница 26: ...any flammable materials 4 When refueling your power equipment never smoke or refuel near any flame or ignition devices Never refuel while the unit is running If during the refueling process some fuel...

Страница 27: ...C will repair or replace at its option any part that is proven to be defective in material or workmanship under normal usage Repairs and or replacement will be made without charge for parts or labor A...

Страница 28: ...the latest product information available at the time of approval for printing We reserve the right to make changes at any time without notice and without incurring any obligation The copyright of this...

Страница 29: ...v a i l a b l e a t t h e t i m e o f a p p r o v a l f o r p r i n t i n g We r e s e r v e t h e r i g h t t o m a k e c h a n g e s a t a n y t i m e w i t h o u t n o t i c e a n d w i t h o u t...

Отзывы: