Operation of Water Pump
(continued)
Starting the Engine
:
1.
Prime the pump.
2.
Move the fuel cock to the “ON” position.
3.
To start a cold engine, push the choke lever to the “CLOSED” position (Refer
to Diagram 1 below.)
To restart a warm engine, leave the choke level in the “OPEN” position.
4.
Move the throttle valve lever slightly to the “FAST” position. (Refer to
Diagram 2 below.)
5.
Turn the engine switch to the “ON” position (Refer to Diagram 3 below.)
6.
Pull the recoil starting handle lightly until resistance is felt, then pull briskly.
Do NOT allow the starter handle to snap back against the engine. Return it
gently to prevent damage to the starter.
7.
Once the engine has started, gradually move the choke lever to the “OPEN”
position.
DIAGRAM 1 DIAGRAM 2 DIAGRAM 3
Setting the Engine Speed
1.
After starting the engine, move the throttle valve lever to the “FAST” position
for self-‐priming, then check the pump output.
2.
To adjust the pump output (which is controlled by the engine speed), move
the throttle valve lever as needed to attain desired pump output. Moving the
throttle valve in the “FAST” direction will increase the pump output and
moving the throttle vale in the “SLOW” direction will decrease pump output.