background image

Introduction

1

1.0

I

NTRODUCTION

1.1

Description 

The Liebert VFD Control Condenser, Model TCDV, is an air cooled direct-drive refrigeration con-

denser designed to reject the heat from a precision air conditioning unit to the outdoor air. The con-

denser uses a Variable Frequency Drive (VFD) to control fan speed, which provides positive 

refrigerant head pressure control for outdoor ambients as low as -20°F (-28.9°C).

Figure 1

Liebert Model TCDV Condenser—2-fan

1.2

Application

The VFD Control Condenser is applied to precision air conditioning units with dual refrigeration cir-

cuits, including units with digital scroll compressors.

1.3

Features and Benefits

• Variable Frequency Drive (VFD)—Programmed at the factory to integrate fluctuating head pres-

sure signals created by compressor unloading, including digital scroll compressors, and varying 

condenser capacity created by lower ambient temperatures.

• The VFD adjusts fan speed to provide stable fan speeds and condensing temperatures.
• Provides protection for motor overload and incoming power supply phase loss, undervoltage 

and overvoltage.

• Built-in EMC filter—Electromagnetic emission levels comply with EN61800-3 (Second Envi-

ronment - Light Industrial Applications).

• Inverter duty motor with permanently lubricated ceramic ball bearings for reliability
• Transducers on each circuit sense refrigerant pressures, providing input to the VFD
• Standard TVSS—Transient Voltage Surge Suppression increases condenser reliability by build-

ing in a layer of electrical protection against electrical failure caused by transient voltage surges 

from unconditioned power sources and atmospheric discharges.

• Standard Locking disconnect
• Contacts for monitoring VFD and TVSS alarm conditions
• Available in 2-, 3- or 4-fan, dual-circuit condenser models

Содержание TCDV165

Страница 1: ...Precision Cooling For Business Critical Continuity Liebert VFD Condenser Model TCDV Product Information Manual 50 60Hz ...

Страница 2: ......

Страница 3: ...ontacts 7 3 9 Electrical Controls 7 FIGURES Figure 1 Liebert Model TCDV Condenser 2 fan 1 Figure 2 Major electrical control components 2 Figure 3 Cabinet and anchor dimensional data VFD control condensers 50 and 60Hz 5 Figure 4 Electrical field connections VFD control condensers 6 TABLES Table 1 Electrical data 50 and 60 Hz 2 Table 2 VFD condensers for indoor units 50 and 60Hz 2 Table 3 Condenser ...

Страница 4: ...ii ...

Страница 5: ...ing including digital scroll compressors and varying condenser capacity created by lower ambient temperatures The VFD adjusts fan speed to provide stable fan speeds and condensing temperatures Provides protection for motor overload and incoming power supply phase loss undervoltage and overvoltage Built in EMC filter Electromagnetic emission levels comply with EN61800 3 Second Envi ronment Light In...

Страница 6: ... 95 F 35 C 100 F 38 C 105 F 41 C DH VH75A N A N A TCDV165 N A N A N A DH VH114A TCDV165 TCDV165 TCDV205 N A N A N A DH VH125A TCDV165 TCDV165 TCDV205 N A N A N A DH VH199A TCDV205 TCDV308 TCDV308 N A N A N A DH VH245A TCDV308 TCDV308 TCDV415 N A N A N A DH VH290A TCDV308 TCDV415 TCDV415 N A N A N A DH VH380A TCDV415 TCDV510 N A N A N A N A DS VS028A TCDV165 TCDV165 TCDV205 TCDV205 TCDV205 TCDV251 ...

Страница 7: ...90 148 7 423 075 123 9 338 460 99 1 253 845 74 3 16 923 8 9 24 800 42 135 78 5 4 TCDV510 552 240 161 7 460 200 134 8 368 160 107 8 276 120 80 9 18 408 9 7 19 200 32 621 R 407C Refrigerant TCDV165 143 160 41 9 119 300 34 9 95 440 27 9 71 580 21 0 4772 2 5 13 300 22 597 75 5 2 TCDV205 242 100 70 9 201 750 59 1 161 400 47 3 121 050 35 4 8070 4 3 11 200 19 029 TCDV251 277 380 81 2 231 150 67 7 184 920...

Страница 8: ... 680 133 1 378 900 110 9 303 120 88 8 227 340 66 6 15 156 8 0 20 600 35 000 74 0 4 TCDV510 479 040 140 3 399 200 116 9 319 360 93 5 239 520 70 1 15 968 8 4 16 000 27 184 R 407C Refrigerant TCDV165 129 960 38 1 108 300 31 7 86640 25 4 64 980 19 0 4 332 2 3 11 100 18 859 71 0 2 TCDV205 212 280 62 2 176 900 51 8 141520 41 4 106 140 31 1 7 076 3 7 9 300 15 801 TCDV251 250 920 73 5 209 100 61 2 167280 ...

Страница 9: ...356 164 4166 82 2083 80 2032 815 370 TCDV510 4 171 1 2 4356 164 4166 82 2083 80 2032 1188 540 All condenser fan motors are 3 4 hp 1 7 8 47 6mm DPN001049 Rev 0 1 3 4 44 5mm 4 1 4 108mm 1 3 4 44 5mm 4 1 4 108mm 1 25 4mm 1 7 8 47 6mm Typical Footprint Typical Diameter 9 16 14 3mm Unit Anchor Plan 4 legs furnished for 2 and 3 fan models 6 legs furnished for 4 fan models B D C 37 11 16 957mm A 70 1778m...

Страница 10: ... electric panel Earth ground connection 60Hz Connection terminal for field supplied earth grounding wire when factory disconnect is supplied Earth ground bar optional on 50Hz only Connection terminals with factory ground from each high voltage component for field supplied earth grounding wire Factory installed fuse block on 60Hz units Circuit breaker supplied in lieu of fuse block on 50Hz units El...

Страница 11: ...ture controlled fan motor shall have built in over load protection All motors shall have rain slingers permanently lubricated bearings and shall be rig idly mounted on die formed galvanized steel supports 3 5 Head Pressure Control The Liebert VFD Condenser control system shall include a variable frequency drive inverter duty fan motor operating from 0 to 100 motor RPM based on head pressure refrig...

Страница 12: ...mes referred to are trademarks or registered trademarks of their respective owners Technical Support Service Web Site www liebert com Monitoring 800 222 5877 monitoring emersonnetworkpower com Outside the US 614 841 6755 Single Phase UPS 800 222 5877 upstech emersonnetworkpower com Outside the US 614 841 6755 Three Phase UPS 800 543 2378 powertech emersonnetworkpower com Environmental Systems 800 ...

Отзывы: