pag. 11
Tab. 3 -- 50 Hz Technical data for “FREECOOLING” and “48Vdc EMERGENCY FREECOOLING” unit
versions (FC and EFC--DC) coupled with “HPSCxx0”
Model
HPS 06
HPS 08
Operating limits
Main power supply voltage
230V ±10% / 1Ph / 50Hz
400V±10% / 3Ph+N+PE / 50Hz
Emergency power supply voltage
48VDC ±17%
(with emergency cooling)
(*)
Outdoor conditions
(**)
from:
10
°
C
Outdoor conditions
(**)
to:
48
°
C
45
°
C
Indoor conditions with compressor running
from:
24
°
C, 30% R.H.. / 80% R.H.
(***)
Indoor conditions with compressor running
to:
35
°
C, 40% R.H.
30
°
C, 40% R.H.
Storage conditions
from:
---40
°
C, 5% R.H.
Storage conditions
to:
55
°
C, 90% R.H.
Sound pressure level
Outdoor sound pressure level
(1)
dB(A)
50
Indoor sound pressure level
dB(A)
57
62
Standard electrical features
Compressor --- AC power input
(2)
kW
1.57
2.17
Compressor --- AC operative current (OA)
(2)
A
7.3
3.9
Compressor --- AC max. current (FLA)
A
11.4
5.1
Compressor --- AC starting current (LRA)
A
47.0
32.0
Condenser fan --- AC power input
(2)
kW
0.08
0.10
Condenser fan --- AC max. power input
kW
0.08
0.10
Condenser fan --- AC operative current (OA)
(2)
A
0.6
0.7
Condenser fan --- AC max. current (FLA)
A
1.4
1.4
Condenser fan --- AC max. current (FLA)
A
1.6
1.6
Evaporator fan --- DC power input
(2)
kW
0.10
0.28
Evaporator fan --- DC operative current (OA)
(2)
A
2.6
5.8
Evaporator fan --- DC max. current (FLA)
(3)
A
2.6
9.6
Evaporator fan --- DC starting current
A
0.1
0.1
Electric heating (optional)
Heating capacity
kW
1.5
3.0
Heating --- max. current
A
6.5
OA:
Standard Operating Ampère
FLA:
Full Load Ampère
LRA:
Locked Rotor Ampère
Notes:
(*)
The emergency cooling option (EFC) is required.
(**)
Maximum outdoor temperature referred to 30
û
C / 35% R.H. indoor unit air suction (HPSE).
(***)
Conditions referred to the suction sections of the inner unit (HPSE); the min. indoor temperature is referred to 30% of indoor relative humidity and to the min.
outdoor temperature; for higher relative humidity and/or outdoor temperatures, the min. indoor temperature is higher than the table data.
(1)
Measured with 35
û
C outdoor temperature at 2m far from the unit; free field conditions.
(2)
Indoor reference conditions: 30
û
C / 35% R.H. at the HPSE indoor unit air suction sides; 35
û
C outdoor. Nominal power supply.
(3)
It refers to nominal speed (Factory setting).
Содержание HIROSS HPS 06L
Страница 1: ...SERVICE MANUAL Issued by T D Service English Cod 273000 Rev 16 02 2006 H P S...
Страница 2: ......
Страница 31: ...pag 27 Fig 3 Condenser positions...