background image

1050 Dearborn Drive  Columbus, OH 43229    614-888-0246

Technical Support

U.S.A...............................................................1-800-222-5877
Outside the U.S.A ...........................................614-841-6755
U.K................................................................ +44 (0) 1793 553355
France ...........................................................+33 1 4 87 51 52
Germany ...................................................... +49 89 99 19 220
Italy .............................................................. +39 2 98250 1
Netherlands.................................................. +00 31 475 503333
Internet.......................................................... [email protected]
Web site ....................................................…

 

http://www.liebert.com

Worldwide FAX Tech Support......................…614-841-5471

The Company Behind The Products

With more than 500,000 installations around the
globe, Liebert is the world leader in computer
protection systems. Since its founding in 1965,
Liebert has developed a complete range of
support and protection systems for sensitive
electronics:

 

Environmental systems: close-control air
conditioning from 1.5 to 60 tons.

 

Power conditioning and UPS with power
ranges from 250 VA to more than 1000
kVA.

 

Integrated systems that provide both
environmental and power protection in a
single, flexible package.

 

Monitoring and control — on-site or
remote — from systems of any size or
location

Service and support, through more than 100
service centers around the world, and a 24-hour
Customer Response Center.

R

700-2200 VA

120 V

PowerSure™ Interactive

While every precaution has
been taken to ensure
Corporation assumes no
responsibility, and disclaims all
liability for damages resulting
from use of this information or
for any errors or omissions.

©1998 Liebert Corporation All
rights reserved throughout the
world. Specifications subject to
change without notice.

® Liebert and the Liebert logo
are registered trademarks of
Liebert Corporation. All names
referred to are trademarks or
registered trademarks of their
respective owners.

SL-23550 (2/98) Rev. 5.0

Содержание 700-2200 VA

Страница 1: ...POWER PROTECTION USER MANUAL English 700 2200 VA 120 V PowerSure Interactive R...

Страница 2: ...RESENT UN RESQUE DE CHOC LECTRIQUE OU DE BR LURE PAR TRANSFERT D NERGIE SUIVRE LES PR CAUTIONS QUI S IMPOSENT 4 WHEN REPLACING THE BATTERIES USE THE SAME NUMBER AND TYPE OF BATTERIES PROPER DISPOSAL O...

Страница 3: ...t into the ventilation holes or other openings Maintain a clearance of four 4 inches 102 mm around the UPS for proper air flow and cooling 12 Always turn off the UPS and unplug it before starting the...

Страница 4: ...erSure Interactive contains a light emitting diode LED bar display to indicate load percentage or battery capacity depending upon the mode of operation It also provides self diagnostics a combination...

Страница 5: ...voltage fluctuations without utilizing battery power BI DIRECTIONAL CONVERTER In normal operation the bi directional converter converts utility AC power into regulated DC power to float charge the bat...

Страница 6: ...aintain a minimum of four 4 inches 102 mm clearance around the UPS Maintain an ambient temperature range of 32 to 104 F 0 to 40 C NOTE UPS operation in temperatures above 77 F 25 C reduces battery lif...

Страница 7: ...bottom side so that the front bezel is facing you 5 The Rackmount UPS must be supported by a shelf or rails The front bezel will not support the weight of the UPS CAUTION To increase the stability of...

Страница 8: ...Fault indicator is the second uppermost LED contained in load battery level indicators A flashing LED indicates the UPS has detected a problem An alarm sounds to alert that the UPS requires attention...

Страница 9: ...Fault Indicator Load Battery Level Indicators Alarm Silence Battery Test Button On Off Button Utility High Low Indicator Utility Battery Status Indicator 1 Output Receptacles 2 DB 9 Interface Port 3...

Страница 10: ...DB 9 Interface Port 3 AC Inlet 4 Intellislot Communications Port 5 Circuit Protector or Fuse 6 Site Wiring Fault Indicator On Off Alarm Silence Load Battery Utility High Low Utility R On Off Button Al...

Страница 11: ...gh or low voltage conditions occur the PowerSure Interactive UPS will automatically correct the utility voltage by either lowering or raising the input voltage condition The UPS will continue to corre...

Страница 12: ...ting from battery mode Battery mode supports a full rated load for approximately 5 minutes before it shuts down To increase this time turn off non essential pieces of equipment such as idle computers...

Страница 13: ...ed with stand alone computers network workstations network servers or UNIX hosts via the DB 9 female connector located on the rear of the UPS This capability is used in applications requiring the UPS...

Страница 14: ...s the Ethernet SNMP card Optional SiteNet SNMP Manager software is available to allow communication through several network management systems Contact your local Liebert representative dealer or resel...

Страница 15: ...for reassembly 4 700 1000 1400 VA models gently pull battery wiring out and disconnect the two wires one red and one black 2200 VA models pull apart connectors A and B 5 Grasp white pull tabs located...

Страница 16: ...by pushing towards connector 1000 1400 VA Model To Disconnect Gently pull wiring away To Connect Connect red wire to red terminal then black wire to black terminal by pushing upward 2200 VA Model To...

Страница 17: ...as in Figure 2 Carefully remove the battery retaining plate by pulling it forward Lay the battery retaining plate and screws aside for reassembly 3 700 1000 1400 VA models Gently pull on the white tab...

Страница 18: ...18 Figure 3 Figure 5 Figure 4 Figure 1 Figure 2 Figure 6 Figure 7...

Страница 19: ...e internal fan operates intermittently as needed B UPS failed battery test D UPS shutdown due to output overload time out A B UPS shutdown due to main input relay failure output short circuit A D UPS...

Страница 20: ...ult indicator and diagnostic LED A are illuminated UPS fan failure or battery overcharge UPS requires service Contact your dealer or LTS Fault indicator and diagnostic LED B are illuminated UPS failed...

Страница 21: ...are at 25 C ambient 0 25 50 75 100 0 20 40 60 80 Percent Load Run Time Mins 0 25 50 75 100 0 20 40 60 80 Percent Load Run Time Mins 0 25 50 75 100 0 20 40 60 80 Percent Load Run Time Mins 0 25 50 75 1...

Страница 22: ...supply and from the UPS 1 Remove the fuse holder by inserting a flat blade screwdriver into the slot and pulling out as indicated in the figure above 2 Remove the input fuse 3 Remove the spare fuse f...

Страница 23: ...METERS Output Receptacles 4 5 15R 6 5 15R 6 5 15R 6 5 15R 2 5 20R Voltage 103 VAC to 132 VAC Max Current Rating 5 8 A 8 3 A 11 67 A 18 3 A Frequency 50 Hz or 60 Hz Waveform Sinewave Utility Mode Overl...

Страница 24: ...Receptacles 6 5 15R 6 5 15R 6 5 15R 6 5 15R 2 5 20R Voltage 103 VAC to 132 VAC Max Current Rating 5 8 A 8 3 A 11 67 A 18 3 A Frequency 50 Hz or 60 Hz Waveform Sinewave Utility Mode Overload 200 for 2...

Страница 25: ...25...

Страница 26: ...ng and UPS with power ranges from 250 VA to more than 1000 kVA Integrated systems that provide both environmental and power protection in a single flexible package Monitoring and control on site or re...

Отзывы: