background image

GB/IE/NI

Values above the measurement values: 

–  Room temperature above 50 °C: HH.H
–  Outdoor temperature above 70 °C: HH.H
–  Air humidity above 99 %: 99 %
–  Air pressure above 1050 hPa: 1050 hPa
–  Heat Index above 60 °C: HH.H
–  Dew Point above 60 °C: HH.H
–  Wind Chill above 60 °C: HH.H
–  Rainfall quantity above 9999 mm: HHH
–  Wind  speed  above  50 m / s:  50 m / s
–  

 Degree of protection for wind gauge 
and rain gauge: IPX4 (splash-proof) 

 

WARNING!

The display becomes increasingly less clear in tem-
peratures under approximately –20 °C. Depending 
on the type of battery, power limitations are to be 
expected at low temperatures (normally as of 
–20 °C). Do not place the weather station or the 
external sensor in direct sunlight. 

  CAUTION!

At temperatures above 60 °C (also depending on 
the type of battery), the battery acid may leak.

Power Supply:

Weather station:  

 6 x 1.5 V

 

 (Direct  

current) battery, type AA 

Wind gauge:  

 2 x 1.5 V

 

 

(Direct  

current) battery, type AA 

Rain gauge:  

 2 x 1.5 V

 

 

(Direct  

current) battery, type AA 

Operating life with 
full batteries:  

approx. 90 operating days.

5.  Simplified EU declaration of 

conformity

Hereby, OWIM GmbH & Co. KG, Stiftsbergstraße 1, 
DE-74167 Neckarsulm, GERMANY, declares that the 
product Premium weather station H13726, is in 

compliance with Directives 2014/53/EU, 2011/65/
EU and 2009/125/EC.

The full text of the EU declaration of conformity is avail-
able at the following internet address: www.owim.com 

6. Safety information

  DANGER FOR CHILDREN!

J    

Swallowing batteries could be fatal. Keep batteries 
and the weather station out of the reach of children. 
Consult a doctor immediately if a battery is 
swallowed.

  DANGER OF INJURY!

J    

Remove the batteries from the product when 
empty.

J  

Never short-circuit the connection poles.

J    

This product can be used by children aged from 
8 years and above and persons with reduced 
physical, sensoryor mental capabilities or lack 
of experience and knowledge if they have been 
given supervision or instruction concerning use 
of the product in a safe way and understand 
the hazards involved. Children shall not play with 
the product. Cleaning and user maintenance shall 
not be made by children without supervision.

  CAUTION - MATERIAL DAMAGE!

J  

Only use the specified battery type.

J  

Ensure correct polarity.

J  

Check the batteries regularly for leaks.

J    

If the product is not used for long periods of 
time, remove the batteries.

J    

Do not immerse the weather station or the  
external sensor in water or other liquids. 

J    

Follow the instructions for cleaning and storage 
in this manual.

Содержание 288624

Страница 1: ...IAN 288624 PREMIUM WEATHER STATION PREMIUM WEATHER STATION Operation and Safety Notes...

Страница 2: ...GB IE NI Operation and Safety Notes Page 3...

Страница 3: ...Alarm function Page 15 16 Setting the air pressure unit Page 16 17 Air pressure adjustment Page 16 18 Setting the wind speed unit Page 16 19 Setting the wind alarm Page 16 20 Setting the wind chill a...

Страница 4: ...al injury The word CAUTION warns of possible risks of minor injury or damage POINTS TO FURTHER INFORMATION 3 Intended use The weather station informs you of the current weather conditions and provides...

Страница 5: ...that the product Premium weather station H13726 is in compliance with Directives 2014 53 EU 2011 65 EU and 2009 125 EC The full text of the EU declaration of conformity is avail able at the following...

Страница 6: ...to the point at which the air releases water vapour in the form of fog and or condensate Example if the air is cooled down constantly and the air humidity stays the same the relative air hu midity in...

Страница 7: ...nd speed temperature and humid ity to the weather station on 434MHz frequency Assembled on a mast of approx 25 31mm Can only be assembled in areas free from buildings walls or other obstructions as th...

Страница 8: ...p outdoors The wind must be able to access the wind gauge from all sides to enable the wind force and wind direction to be measured accurately Ensure that the vane and the wind wheel are not blocked t...

Страница 9: ...drill holes using the rain gauge before drilling the holes 5mm ensure that no elec trical cables or water pipes can be damaged 2 Push the supplied dowel into the drilled hole until it is flush with t...

Страница 10: ...he housing carefully off the base of the product To open the battery compartment loosen the 4 cross head screws on the battery compart ment cover Lift off the battery compartment cover Insert the batt...

Страница 11: ...ween temper ature felt by humans Heat Index and dew point Dew Point Button Press once Press for ap prox 3 sec CLOCK Switch display between local time date and day of the week Set date and time ALARM D...

Страница 12: ...ind gauge and rain gauge and registering on the weather station 13 1 Calibrating the wind gauge The wind gauge must be recalibrated when using it for the first time as well as every time the battery i...

Страница 13: ...is confirmed with a confirmation tone The measurement value dis plays now flash on the wind gauge and rain gauge displays The process can take up to 4 minutes 14 Weather station basic settings 14 1 Se...

Страница 14: ...continuously on the display after approx 3 5 minutes Press again to deactivate the DCF 77 synchroni sation WARNING The displays for time and date in Central Europe are transferred via DCF 77 radio si...

Страница 15: ...nia Monaco The Neth erlands Norway Austria Poland San Marino Sweden Switzerland Serbia Slovakia Slovenia Spain with the exception of the Canary Islands Czech Republic Hungary Set 1 Hr Bulgaria Estonia...

Страница 16: ...in inches 17 Air pressure adjustment When batteries have been inserted in the weather station an air pressure of 1013hPa appears on the display This value is pre set You can adjust the air pressure t...

Страница 17: ...on until ALARM appears next to the Wind Chill temperature Hold the WIND ALARM button down for approx 3 seconds until a confirmation tone sounds and the value flashes Use or to set the desired value Pr...

Страница 18: ...tches off automatically 24 1 Date and time Press the CLOCK button to switch between the time date and day of the week If no button has been pressed for a period of approximately 20 seconds the time di...

Страница 19: ...history Example Press the RAIN CLEAR until the rainfall quantity is shown The value shown represents the rainfall quantity for the current day Underneath this value a diagram is shown containing the r...

Страница 20: ...d maximum values Use the MEMORY button to display saved minimum and maximum values 24 11 Weather forecast The weather station can predict the weather for the next 12 24 hours The weather prediction fu...

Страница 21: ...o the main unit Inserting the rain gauge battery the lever at the middle position when pairing to the main unit Then the rain gauge enters the test mode Lever at the middle position Lever at the left...

Страница 22: ...le dispose of it separately for better waste treatment The Triman logo is valid in France only Contact your local refuse disposal au thority for more details of how to dispose of your worn out product...

Страница 23: ...IAN 288624 OWIM GmbH Co KG Stiftsbergstra e 1 DE 74167 Neckarsulm GERMANY Model No H13726 Version 07 2017 Last Information Update 08 2017 Ident No H13726082017 IE NI...

Отзывы: