background image

LDCA608S Digital DC Servo Instruction Manual

LDCA608S Digital DC Servo Instruction Manual

5

6

4

EZ+

Brown

Encoder Z signal is positive

6

HW+

White

Encoder W signal is positive

7

HU+

gray

Encoder U signal is positive

8

HV+

Orange

Encoder V signal is positive

10

EZ-

Brown

black

Encoder Z signal negative

11

EA-

Yellow

black

Encoder A signal negative

12

EB-

Green

black

Encoder B signal negative

13

VCC

red

E 5V input

2

Control port wiring

P2 Common anode connection

P3 Common cathode connection

P4 Differential signal input and output signal connection

Note: 1)

When the control signal voltage VCC = 24V, the current limiting resistor

R = 1.5K;

2) When the control signal voltage VCC = 5V, the current limiting resistor
R = 0;

3

Control signal timing diagram

P

5 Control signal timing diagram

C

on

tro

lle

r

C

on

tro

lle

r

Driver

Driver

C

on

tro

lle

r

Содержание LCDA-608S

Страница 1: ...Contact person Annie Cheng Sales manamger Email annie xlichuan com Address Floor 5th building 9 Jiuxiangling industrial Zoon xili Town Nanshan district Shenzhen city guangdong province China LCDA 608S...

Страница 2: ...anel 5 2 Data monitoring 6 3 Operating procedures 7 4 Specific parameter description 8 Installation 1 Electrical index Voltage input range DC 36V 50V Maximum output current 30A Pulse form pulse direct...

Страница 3: ...put negative 26 GND Internal power ground 4 DIR Direction input positive 20 EA A phase differential pulse feedback output 5 ENA Enable input positive 21 EA 6 ENA Enable input negative 22 EB B phase di...

Страница 4: ...black Encoder A signal negative 12 EB Green black Encoder B signal negative 13 VCC red Encoder 5V input 2 Control port wiring P2 Common anode connection P3 Common cathode connection P4 Differential si...

Страница 5: ...menu confirm input Switchable between modes 2 Data monitoring LED display Description The current position error is converted to the number of code disk lines Current speed feedback rpm Current speed...

Страница 6: ...t loop filter cutoff frequency 350 2500 1100 PA_005 Single and double pulse selection 0 1 0 0 PUL DIR 1 CCW CW PA_006 Pulse active edge selection 0 1 0 PA_007 Positive direction level selection 0 1 0...

Страница 7: ...lus time 1 200 100 PA_040 3rd position command circle 0 32767 50 PA_041 The third position instruction low 0 32767 0 PA_042 Third speed 7000 13000 11200 PA_043 Third period plus time 1 200 100 PA_044...

Страница 8: ...re 1 The brake current of the driver is too large 2 The brake circuit of the driver is damaged Appendix DC servo motor parameters 400WDC servo motor parameter Project Parameter Unit Rated output power...

Страница 9: ...LDCA608S Digital DC Servo Instruction Manual LDCA608S Digital DC Servo Instruction Manual 15 16...