Mounting on flush-mounted 
box

Pass the secondary line of the control gear 
through the opening (A).
Connect the conductor (L) and neutral con-
ductor (N) (marked on the luster terminal) 
of the control gear to the corresponding 
conductor of the ceiling outlet in the luster 
terminal in the flush-mounted box.

Fasten the canopy to the flush-mounted box 
using suitable screws. 
You can also fix the box to the ceiling if re-
quired. Use suitable screws for your ceiling.

Connect (+) and (-) of the secondary line of 
the control gear with (+) red and (-) black 
of the luminaire cable to the connection 
terminals.

Close the canopy with the three screws 
provided.

Attach the cover plate (B) to the canopy by 
screwing in the cable securing device (C). 

Secure the lamp cable against 
Slide out of the cable safety catch by screw-
ing in the grub.

Fastening with hook next to 
the canopy

(D) Attach the hook to the ceiling. Use a 
dowel suitable for your ceiling. Adjust the 
pendulum length and slide the transparent 
shrink tubing over the cable loop. Insert the 
thimble into the cable loop. Tighten the cable 
tie over the shrink tubing. Make sure it is 
tight and shorten the excess length of the 
cable tie.

Mounting on flush-mounted box

(A)

L

N

(B)

(C)

(D)

thimble

cable tie

heat-shrink 
tubing

Содержание Ledl

Страница 1: ...Ledl en ...

Страница 2: ...W light colour warm white dimensions ø 250 x 9 mm anodizing colours grey black red other colours on request 230 V 50 Hz 1 x max 12 W LED max 350 mA Art Indoor light IP20 1 Ledl 1 canopy 1 LED control gear 4 terminal blocks 1 hook 1 thimble kabel tie heat shrinking tube pieces ferrules This luminaire contains built in LED lamps Energy classes A A The lamp can only be replaced by the manufacturer pr...

Страница 3: ... respected The manufacturer accepts no liability for any damage due to improper use of the luminaire Luminares are only allowed to be used for the specified purpose Interior lights may not be used in outside area Luminares may not be covered They may not be connected to power supply still they are packaged Lights with elctronic control gears ECG have to be operated with original ECGs Attention Bef...

Страница 4: ...the outer sheath Please be careful The coaxial braid must not be damaged Then twist the coaxial braid into a conductor Provide this with a piece of shrink tubing Then a larger one over the place where the two conductors share Insulate both conductors by approx 10 mm Finally squeeze the conductors with one ferrule each Before you start mounting and connecting the luminaire make sure that the supply...

Страница 5: ...ed and black of the luminaire cable to the connection terminals Close the canopy with the three screws provided Attach the cover plate B to the canopy by screwing in the cable securing device C Secure the lamp cable against Slide out of the cable safety catch by screw ing in the grub Fastening with hook next to the canopy D Attach the hook to the ceiling Use a dowel suitable for your ceiling Adjus...

Страница 6: ...vided Attach the cover plate B to the canopy by screwing in the cable securing device C Secure the lamp cable against slipping out on the cable securing device by screwing in the grub Fastening with hook next to the canopy D Attach the hook to the ceiling Use a dowel suitable for your ceiling Adjust the pendulum length and slide the transparent shrink tubing over the cable loop Insert the thimble ...

Страница 7: ...Lichtlauf GmbH Sonnentaustraße 12 80995 München T 49 0 89 30905274 0 F 49 0 89 30905274 9 info lichtlauf de www lichtlauf de ...

Отзывы: