background image

C. INSTALLATION

WARNING:

 FOLLOW THE MOUNTING INSTRUCTIONS CAREFULLY. 

A FAULTY INSTALLATION MAY CAUSE SERIOUS INJURIES!

• Before proceeding with the installation, remove all unnecessary packages and disable any 

unused equipment ;

• Make sure that the door can be easily opened and closed manually and check that it is in good 

mechanical condition and properly balanced;

• Fix the garage door opener so that the emergency release rope can be reached at an height 

lower than 1,8m   from the floor;

• Install any automation system permanent controls within the door sight range but far enough from 

any moving part and at a minimum height of 1,5m;

• Affix, in outstanding position or near the permanently mounted controls, warning signals 

indicating the risk of being caught in the door movement;

• Clearly   indicate   the emergency release system;

• Once you have completed the installation, make sure that the mechanical structure is properly 

adjusted and check that door reverses the closing movement when detecting any obstacle 
higher than 40cm from the floor;

• Make sure that the door movement does not hinder public roads or footpaths;

• Make sure that the garage door opener stops any opening movement when a minimum load of 

20 Kg is centrally   fixedon the bottom edge of the door;

REQUIRED TOOLS

 

 

 

WARNING

3

GB

GB

Содержание Gear motor 230V for sectional

Страница 1: ...stallation et utilisation 2007_01 Motoriduttore 230V per l automazione di porte da garage sezionali o basculanti Automatisme 230V 24V pou porte de garage sectionelles ou basculante d bordante Gear mot...

Страница 2: ...away from children Keep watching on the door s movement and do not approach to the door until it s completely open or has come to a complete stop Check regularly the automation operating condition in...

Страница 3: ...Straight door bracket 1 Chain 1 Emergency release rope 1 Trolley 1 Gearmotor with incorporated control unit Instructions manual Radio transmitter Bent door arm Mounting bracket Support bracket Front w...

Страница 4: ...shown in the picture 3 Join the rail parts together through the provided connectors in a way that the catches are in sight 4 Tighten the nut with a 13 sleeve 5 Adjust distance as shown in the picture...

Страница 5: ...oor sight range but far enough from any moving part and at a minimum height of 1 5m Affix in outstanding position or near the permanently mounted controls warning signals indicating the risk of being...

Страница 6: ...all Driving screw 6x15 Door Bent door arm Front wall fixing bracket Support bracket Screw 6x80 Screw 8x20 Rail Mounting bracket Rawlplug Rawlplug Door fixing bracket U bracket Inserted pin 8x25 Screw...

Страница 7: ...door D GEARMOTOR AND CONTROL UNIT Rail Trolley clutch Emergency rope WHEN POWER RECOVERS Give a start impulse to the garage door opener through the radio transmitter or through a permanently mounted c...

Страница 8: ...see page 10 Power failure The door can be open manually by pulling down on the emergency release rope see page 5 Accessory devices A photocell connection is available on the control unit see page 14...

Страница 9: ...LIMIT SETTING Keep pressing P key about 8 seconds Till the control unit beeps once and the display shows 1 Press P again 1 must flash Keep pressing key Till the door has come to the complete open posi...

Страница 10: ...or stops press P key twice The door automatically closes Then press P key to save the setting Once the full cycle has finished you can press key to select menu 1 and then keep pressing P key till the...

Страница 11: ...e photocells beam If the display shows an A then photocells have been connected properly If A does not appear on the display you have to check again the photocells connection Then press P key to save...

Страница 12: ...s and so on Press key till the display shows 7 Press P Then press to set the alarm function ON Or press to set the alarm function OFF Then press P key to save the setting 30 sec Press key till the dis...

Страница 13: ...e 2000 cycles alert is OFF Press key till the display shows 0 to set the 2000 cycles alert OFF Press key till the display shows 1 to set the 2000 cycles alert ON Press P key to save the settings Exit...

Страница 14: ...ssing S till 0 appears in the left side of display Hold on pressing S till the 0 disappears from the display Press any key of the radio transmitter twice before the 0 disappears Now the coding procedu...

Страница 15: ...put Light connection Power supply 230V Microchip Control unit Radio unit Photocells contact Plug for external control Photocells plug Microswitch encoder plug Display plug Motor plug Ground connection...

Страница 16: ...ING DIAGRAM Optional devices WARNING Breaking the photocells beam while the door is closing immediatly stops the movement while it doesn t affect in opening COM OUT Control unit 12V R GND Photocells r...

Страница 17: ...door reach the closed position as previously set and stops still TROUBLESHOOTING Problem Probable Cause Possible Solution The door doesn t move No radio transmitter code Code the radio transmitter aga...

Отзывы: