background image

E3.

E4.

.

FORCE SETTING

PHOTOCELLS SETTING

This function is normally inactive from factory settings.
If you don't want to install any photocell you don't need to carry out this procedure.
You can skip to the next setting menu by pressing “

-

“ key twice

 

 

Press  “

-

” key till the 

display shows “

3

Press “

P

” , “

3

” must flash

The door automatically 

opens

      

 

 

 

When the door stops, 
press “

P

” key twice 

The door automatically

closes

Then press “

P

” key to 

save the setting

  

 

        

 

Once the full cycle has finished, you can press “

+

” key to select menu “

1

” and 

then keep pressing “P” key till the display shows “

0

”. 

Now the basic commissioning procedure has been completed.

 

 

 

Press “

-

” key till the 

display shows “

4

” 

      

Press “

P

” , “

4

” must flash

  

Press “

+

” key to activate

the photocell function; 
the control unit will beep once

 

 

 

 

Press “

-

” key to turn 

off the photocell 
function; the control 
unit will beep twice   

  

Then press “

P

” key

to save the settings

 

 

 

 

 

WARNING

8

GB

GB

Содержание Gear motor 230V for sectional

Страница 1: ...stallation et utilisation 2007_01 Motoriduttore 230V per l automazione di porte da garage sezionali o basculanti Automatisme 230V 24V pou porte de garage sectionelles ou basculante d bordante Gear mot...

Страница 2: ...away from children Keep watching on the door s movement and do not approach to the door until it s completely open or has come to a complete stop Check regularly the automation operating condition in...

Страница 3: ...Straight door bracket 1 Chain 1 Emergency release rope 1 Trolley 1 Gearmotor with incorporated control unit Instructions manual Radio transmitter Bent door arm Mounting bracket Support bracket Front w...

Страница 4: ...shown in the picture 3 Join the rail parts together through the provided connectors in a way that the catches are in sight 4 Tighten the nut with a 13 sleeve 5 Adjust distance as shown in the picture...

Страница 5: ...oor sight range but far enough from any moving part and at a minimum height of 1 5m Affix in outstanding position or near the permanently mounted controls warning signals indicating the risk of being...

Страница 6: ...all Driving screw 6x15 Door Bent door arm Front wall fixing bracket Support bracket Screw 6x80 Screw 8x20 Rail Mounting bracket Rawlplug Rawlplug Door fixing bracket U bracket Inserted pin 8x25 Screw...

Страница 7: ...door D GEARMOTOR AND CONTROL UNIT Rail Trolley clutch Emergency rope WHEN POWER RECOVERS Give a start impulse to the garage door opener through the radio transmitter or through a permanently mounted c...

Страница 8: ...see page 10 Power failure The door can be open manually by pulling down on the emergency release rope see page 5 Accessory devices A photocell connection is available on the control unit see page 14...

Страница 9: ...LIMIT SETTING Keep pressing P key about 8 seconds Till the control unit beeps once and the display shows 1 Press P again 1 must flash Keep pressing key Till the door has come to the complete open posi...

Страница 10: ...or stops press P key twice The door automatically closes Then press P key to save the setting Once the full cycle has finished you can press key to select menu 1 and then keep pressing P key till the...

Страница 11: ...e photocells beam If the display shows an A then photocells have been connected properly If A does not appear on the display you have to check again the photocells connection Then press P key to save...

Страница 12: ...s and so on Press key till the display shows 7 Press P Then press to set the alarm function ON Or press to set the alarm function OFF Then press P key to save the setting 30 sec Press key till the dis...

Страница 13: ...e 2000 cycles alert is OFF Press key till the display shows 0 to set the 2000 cycles alert OFF Press key till the display shows 1 to set the 2000 cycles alert ON Press P key to save the settings Exit...

Страница 14: ...ssing S till 0 appears in the left side of display Hold on pressing S till the 0 disappears from the display Press any key of the radio transmitter twice before the 0 disappears Now the coding procedu...

Страница 15: ...put Light connection Power supply 230V Microchip Control unit Radio unit Photocells contact Plug for external control Photocells plug Microswitch encoder plug Display plug Motor plug Ground connection...

Страница 16: ...ING DIAGRAM Optional devices WARNING Breaking the photocells beam while the door is closing immediatly stops the movement while it doesn t affect in opening COM OUT Control unit 12V R GND Photocells r...

Страница 17: ...door reach the closed position as previously set and stops still TROUBLESHOOTING Problem Probable Cause Possible Solution The door doesn t move No radio transmitter code Code the radio transmitter aga...

Отзывы: