Liberty Pumps XLE100 Series Скачать руководство пользователя страница 1

Approved for Hazardous Locations

Class I, Division 1, Groups C and D T4
Class I, Zone 1, Groups IIA and IIB T4

Installer: Manual must remain with owner or 

operator/maintainer.

Prior to installation, record information

from pump nameplate for future reference:

Keep this manual handy for future reference.

For replacement manual, visit LibertyPumps.com, 

or contact Liberty Pumps at 1-800-543-2550.

Retain dated sales receipt for warranty.

Model:

7000 Apple Tree Avenue
Bergen, NY 14416
ph: 1-800-543-2550
fax: 1-585-494-1839
www.LibertyPumps.com

Serial:

Mfg Date:

Install Date:

Installation 

Manual

3473000C

Copyright © Liberty Pumps, Inc. 2021 All rights reserved.

Explosion-Proof Submersible Sewage Pumps

XLE-Series

Models

XLE50-Series

1/2 hp

XLE70-Series

3/4 hp

XLE100-Series

1 hp

XLE150-Series

1-1/2 hp

Содержание XLE100 Series

Страница 1: ...rence For replacement manual visit LibertyPumps com or contact Liberty Pumps at 1 800 543 2550 Retain dated sales receipt for warranty Model 7000 Apple Tree Avenue Bergen NY 14416 ph 1 800 543 2550 fa...

Страница 2: ...res inside the power cord The electrical power supply shall be located within the length limitations of the pump power cord and for below grade installations it shall be at least 4 ft 1 22 m above flo...

Страница 3: ...te and Local codes and ordinances for hazardous locations All electrical terminations shall be made according to Federal State and Local codes for hazardous or classified locations Conduit junction bo...

Страница 4: ...complete If storage is necessary the pump should remain in its shipping container It should be stored in a warehouse or storage shed that has a clean dry temperature stable environment where the pump...

Страница 5: ...rly sized or adjusted for the full load input power indicated on the pump nameplate It is important to properly select and adjust the motor control overload protection The full load amperes on the nam...

Страница 6: ...e pump has cooled 1 phase models automatically reset after the pump has cooled to a safe temperature Power and Control Cords Do not remove cord and strain relief and do not connect conduit to pump The...

Страница 7: ...into the pump intake The pump can remain upright or can be laid down on its side for easier access to the intake Besides verification that the impeller is freely spinning rotating the impeller helps t...

Страница 8: ...skets and components are present Pump Record information from pump nameplate onto inside cover of these instructions Complete a visual inspection before lowering into basin Place pump in basin making...

Страница 9: ...further assistance To keep the pump pump system operating smoothly perform the following routine checks Monthly Pumps that are idle for more than a month in a dry basin should have impellers manually...

Страница 10: ...s trip Unintentional ground Turn off power and check motor leads for possible ground 3 phase motor winding failure Check resistance of motor windings All three phases should have the same reading Obst...

Страница 11: ...pen gate or ball valve Total head is beyond pump s capability Route piping to a lower level If not possible a larger pump may be required Consult Liberty Pumps Obstructed impeller or volute clogged in...

Страница 12: ...mages including costs of removal reinstallation or transportation There is no other express warranty All implied warranties including those of merchantability and fitness for a particular purpose are...

Отзывы: