2-3 

STORAGE BEFORE USE 

 
 

 
 

Only place the pump in a wet pit when it can be operated. Water can wick 
through the power cord into the pump causing an electrical short from the 
pump to its surroundings.

 

 

 

 

If it is necessary to store this backup pump system for a long period of time, it should be stored indoors in a clean, dry, tempera-
ture-stable environment. The pump, charger, and user interface should be covered for protection from dirt and water. All cable 
ends must be protected against moisture. 

 
2-4 

PRODUCT DESIGN 

 

 

While this pump  has been designed to operate  for long periods of time, it is  not intended to be  solely operated as a primary 
pump.  

 

This backup pump has a check valve incorporated into the discharge of the volute, and therefore does not require the installation 
of a check valve in the backup pump discharge line. However, if this backup is connected into the primary pump’s discharge 
line, a check valve  must be installed for the primary pump prior to the tee where the backup pump’s discharge connection is 
made. 

See Section 2-6.

 

 

This pump has been designed to directly accept a 1.5” pipe or street fitting to integrate into the discharge piping. 

 

You can test your battery backup pump with the push of button. Simply push the pump test button on your StormCell

®

 interface 

and your pump will run itself to verify that the pump is in working order. 

 

The float is easily installed: snap the float onto any 1.5” pipe, then adjust it to the desired height. The pipe clamp is made of 
PVC; if desired, it can be glued in place on the pipe using PVC primer and cement. 

 

The communication cable between your user interface and battery backup charger is a standard shielded Ethernet cable. If you 
wish to move your device more than 8 feet away from the charger, you can purchase a longer shielded Ethernet cable. Be sure it 
is a shielded cable; it should have a metal wrap around the outside of the connector that makes contact with the Ethernet jack. 
You can use the cable provided with your charger for an example of a shielded connector. DO NOT use a standard non-shielded 
cable; use of non-shielded cables may cause communication issues between your charger and UI. 

 

This product has built-in high water level alarm functionality. In addition to sounding an alarm, the high water level float switch 
will act as a redundant pump switch in the event that the primary 442 backup pump switch has failed. If this occurs (or any other 
scenario occurs that results in the float switches operating out of order) the user interface and charger will signal a float fault. 

 

The backup pump interface has audible alerts that signal a low battery condition or that the 442 backup pump is running. If your 
system is equipped with NightEye

®

 functionality this information (and more) can be viewed from the associated mobile device. 

Refer to NightEye

®

  quick-start guide for more information. 

2-5 

BATTERY SELECTION 

 
 
 
 
 
 
 
 

 

For the longest battery life, a deep cycle battery must be used with this backup system. Deep cycle batteries are designed to han-
dle multiple long deep discharges. 

For best results, install a Liberty Pumps StormCell

®

 Battery with your backup pump. 

However, if you choose to supply your own deep cycle battery, any 12V lead-acid battery may be used safely  with Liberty’s 
charging system. 

 

For greatest system capacity, deep cycle group 27 and 31 batteries are recommended. Larger batteries can be used, charged, and 
maintained with this system, though these batteries will not fit in the Liberty supplied battery box. In the event of an extended 
power outage, any charged 12 Volt DC car battery can be substituted for  your deep cycle  battery to prevent flooding. When 
power returns, be sure to put your deep cycle battery back into service with your backup system. 

 

 

Only use 12 volt lead acid batteries with this backup system. Use of 
batteries with higher or lower output voltages, can damage your 
backup up system, leak acid, or explode. 

Содержание StormCell 442 Series

Страница 1: ...or future reference If manual becomes lost or damaged get a replacement manual at http www libertypumps com or contact Liberty Pumps Read manual before using pump Follow all safety instructions in man...

Страница 2: ...ose the electrically live wires inside the power cord DO NOT bypass grounding wires The electrical power supply shall be located within the length limitations of the pump power cord and for below grad...

Страница 3: ...ited RISK OF SERIOUS INJURY OR DEATH The pump must be installed in accordance with all applicable codes and ordinances DO NOT allow children to play with the pump DO NOT allow children or any person w...

Страница 4: ...mation on installation 2 Introduction This manual was prepared to assist you in the correct installation operation and maintenance of your Liberty Pumps product Before Installation read the following...

Страница 5: ...ded cable it should have a metal wrap around the outside of the connector that makes contact with the Ethernet jack You can use the cable provided with your charger for an example of a shielded connec...

Страница 6: ...n larger sump pits when it is desirable to have the backup pump and primary pump on the same level This installation will require a tee a 90 elbow and two sections of piping A 90 street elbow is suppl...

Страница 7: ...the 442 pump 5 Install the tee and pre glued nipple into the 442 pump discharge Tighten the hose clamp to 15 in lbs and mock up your 442 installation inside the sump pit without glue Ensure that the...

Страница 8: ...to the charger and the user interface 5 Connect the charger battery leads to the battery or batteries in the case of a 442 25A ensuring that the connection is made first followed by the 6 Install a 9V...

Страница 9: ...pump is activated Fault LED indicates a system fault Navigation Buttons scroll through notifications on UI LCD Alarm Silence Button Resets after 6 hours or if Silence button is pressed again StormCell...

Страница 10: ...are no faults or notifi cations Explanation LCD home screen when system has faults and or notifications Number of message can be greater than 1 Explanation Standard LCD notification not directly indic...

Страница 11: ...ve the 12V battery tested Probable Symptom Low battery alarm pump not running Check Check all wiring connections If AC power is out and the battery is ex hausted it will charge upon return of AC power...

Страница 12: ...anty if the product has not been properly installed if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been r...

Отзывы: