TROUBLESHOOTING OTHER ISSUES 

Motor hums but pump does not run: 

1.  Battery charge has dropped below that which is required to run the pump. This can be temporarily rectified by swapping the 

dead battery for a charged battery. 

2.  Check for jammed pump impeller. 
 

Pump runs but pumps very little or no water / Pump cycles too frequently: 

1.  Ensure that check valve is installed and functioning between primary pump discharge and 442 connection tee. 
2.  Check for obstruction in discharge pipe. 
3.  Discharge pipe length and / or height exceeds capacity of pump. 
 

Probable Symptom: 

Failed fuse, fuse LED illuminated, pump not running. 

Check: 

Check all wiring connections, replace pump control fuse if required. Also, 

verify that the pump has not jammed causing the fuse to fail. After fuse replace-
ment, test pump to confirm the problem is fixed. 

Probable Symptom: 

Low battery alarm. 

Check: 

Check all wiring connections. If AC power is out and the battery is 

exhausted, it will charge upon return of AC power. If problem persists have the 
12V battery tested. 

Probable Symptom: 

Low battery alarm, pump not running. 

Check: 

Check all wiring connections. If AC power is out and the battery is ex-

hausted, it will charge upon return of AC power. If problem persists have the 12V 
battery tested. If power is out, replace the 12V battery with a charged battery. 

Probable Symptom: 

Battery will not charge, eventual low battery alarm. 

Check: 

Check all wiring connections. If nothing is disconnected, have 12V battery 

tested. 

Check: 

This notification occurs when floats actuate out of order.  Check floats for 

binding and / or buildup. The 442 battery backup has integrated float redundancy so 
this error does not necessarily mean the pump will not operate. 

Probable Symptom: 

Battery will not charge, pump will not run, alarm sounding. 

Check

: Check all wiring connections, paying particular attention to the battery cable 

connections. 

NightEye

®

 Enabled Systems Only

, this screen occurs when the Wi-Fi connection 

to your system has been lost. This can be related to your internet connection, router, 
or home network. 

Explanation: 

This notification occurs when there is an active system message that 

indicates a problem that requires attention. This error will occur when clearing 
system messages that have not yet been addressed / fixed. 

Содержание StormCell 442 Series

Страница 1: ...or future reference If manual becomes lost or damaged get a replacement manual at http www libertypumps com or contact Liberty Pumps Read manual before using pump Follow all safety instructions in man...

Страница 2: ...ose the electrically live wires inside the power cord DO NOT bypass grounding wires The electrical power supply shall be located within the length limitations of the pump power cord and for below grad...

Страница 3: ...ited RISK OF SERIOUS INJURY OR DEATH The pump must be installed in accordance with all applicable codes and ordinances DO NOT allow children to play with the pump DO NOT allow children or any person w...

Страница 4: ...mation on installation 2 Introduction This manual was prepared to assist you in the correct installation operation and maintenance of your Liberty Pumps product Before Installation read the following...

Страница 5: ...ded cable it should have a metal wrap around the outside of the connector that makes contact with the Ethernet jack You can use the cable provided with your charger for an example of a shielded connec...

Страница 6: ...n larger sump pits when it is desirable to have the backup pump and primary pump on the same level This installation will require a tee a 90 elbow and two sections of piping A 90 street elbow is suppl...

Страница 7: ...the 442 pump 5 Install the tee and pre glued nipple into the 442 pump discharge Tighten the hose clamp to 15 in lbs and mock up your 442 installation inside the sump pit without glue Ensure that the...

Страница 8: ...to the charger and the user interface 5 Connect the charger battery leads to the battery or batteries in the case of a 442 25A ensuring that the connection is made first followed by the 6 Install a 9V...

Страница 9: ...pump is activated Fault LED indicates a system fault Navigation Buttons scroll through notifications on UI LCD Alarm Silence Button Resets after 6 hours or if Silence button is pressed again StormCell...

Страница 10: ...are no faults or notifi cations Explanation LCD home screen when system has faults and or notifications Number of message can be greater than 1 Explanation Standard LCD notification not directly indic...

Страница 11: ...ve the 12V battery tested Probable Symptom Low battery alarm pump not running Check Check all wiring connections If AC power is out and the battery is ex hausted it will charge upon return of AC power...

Страница 12: ...anty if the product has not been properly installed if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been r...

Отзывы: