This pump and its floats have been evaluated for use with water only. Keep sump clear of debris. Debris can jam the pump and/
or its floats, resulting in flooding. 

 

DO NOT, use this pump as your primary sump pump. 

 

This pump should be placed on a separate, properly fused and grounded branch circuit, from the primary sump pump. This al-
lows your backup to continue to function and charge your battery, in the event your primary pump trips an electrical breaker 
under normal operating conditions 

 

DO NOT use this product to pump corrosive liquids. Pump components can be damaged from corrosive liquids and cause prod-
uct malfunction or failure. 

 

NEVER dispose of materials such as paint thinner or other chemicals down drains. Doing so could chemically attack and dam-
age pump components and cause product malfunction or failure. 

 

DO NOT use pumps with fluid over 40°C.

 

Operating the pump in fluid above this temperature can overheat the pump, resulting 

in pump failure.

 

 

DO  NOT use  pumps  with  mud, sand, cement,  oil or chemicals. Pump components can be  damaged from these  items causing 
product malfunction or failure. Additionally, flooding can occur if these items jam the impeller or piping. 

 

DO NOT modify the pump in any way. Modifications may affect seals, change the electrical loading of the pump, or damage the 
pump and its components. Modifications can void your warranty on this product.  

 

DO NOT run this pump dry. 

 

Batteries and their chargers generate Carbon Monoxide (CO) during normal operation. To avoid nuisance alarms, make sure that 
any CO detectors are a minimum of 15 feet away from this backup product. Please refer to your CO detector manual for more 
information on installation. 

2.   Introduction  

This manual was prepared to assist you in the correct installation, operation, and maintenance of your Liberty Pumps product. Before 
Installation,  read  the  following  instructions  carefully.  Each  Liberty  pump  is  individually  factory  tested  to  provide  proper 
performance. Liberty pumps are designed for minimal maintenance. However, regular inspections will ensure longer life and greater 
operating reliability. Make certain that you understand the chapters on electrical connection and mechanical installation before start-
ing the installation of your Liberty pump. By closely following these instructions, potential operating problems should be eliminated, 
providing years of trouble-free service. 

 
2-1 

INTRODUCTION 

WARRANTY:

 Repair work carried out during the warranty period without prior factory approval may render the warranty void. 

SERIAL #:

 In all correspondence and reports with the factory, provide the pump serial number to ensure that you receive the proper 

information and replacement parts. 

 
2-2 

INSPECTION UPON RECEIPT 

The shipping carton should be immediately inspected for damage that may have occurred during shipment. Exercise care in opening 
the shipping carton to avoid damaging the components of this backup system. Remove packaging from the container ensuring that all 
components have been accounted for before discarding it. Visually check the pump, cables, and any spare parts for damage. Contact 
the Liberty Pumps Customer Service Department (toll free phone number located on the front cover) to report any damage or short-
age of parts. 

 

Within your shipping carton you should find the following components: 
 

 

(1) 12V 442 pump 

 

(1) StormCell

®

 battery charger 

 

(1) Charger power cable 

 

(1) StormCell

®

 user interface (UI) / alarm 

 

(1) Snap-on float switch assembly 

 

(1) Bag of pump and charger mounting hardware 

 

(1) Charger to UI communication cable (RJ45) 

 

(1) Battery Box 

 

Instruction manuals 

Содержание StormCell 442 Series

Страница 1: ...or future reference If manual becomes lost or damaged get a replacement manual at http www libertypumps com or contact Liberty Pumps Read manual before using pump Follow all safety instructions in man...

Страница 2: ...ose the electrically live wires inside the power cord DO NOT bypass grounding wires The electrical power supply shall be located within the length limitations of the pump power cord and for below grad...

Страница 3: ...ited RISK OF SERIOUS INJURY OR DEATH The pump must be installed in accordance with all applicable codes and ordinances DO NOT allow children to play with the pump DO NOT allow children or any person w...

Страница 4: ...mation on installation 2 Introduction This manual was prepared to assist you in the correct installation operation and maintenance of your Liberty Pumps product Before Installation read the following...

Страница 5: ...ded cable it should have a metal wrap around the outside of the connector that makes contact with the Ethernet jack You can use the cable provided with your charger for an example of a shielded connec...

Страница 6: ...n larger sump pits when it is desirable to have the backup pump and primary pump on the same level This installation will require a tee a 90 elbow and two sections of piping A 90 street elbow is suppl...

Страница 7: ...the 442 pump 5 Install the tee and pre glued nipple into the 442 pump discharge Tighten the hose clamp to 15 in lbs and mock up your 442 installation inside the sump pit without glue Ensure that the...

Страница 8: ...to the charger and the user interface 5 Connect the charger battery leads to the battery or batteries in the case of a 442 25A ensuring that the connection is made first followed by the 6 Install a 9V...

Страница 9: ...pump is activated Fault LED indicates a system fault Navigation Buttons scroll through notifications on UI LCD Alarm Silence Button Resets after 6 hours or if Silence button is pressed again StormCell...

Страница 10: ...are no faults or notifi cations Explanation LCD home screen when system has faults and or notifications Number of message can be greater than 1 Explanation Standard LCD notification not directly indic...

Страница 11: ...ve the 12V battery tested Probable Symptom Low battery alarm pump not running Check Check all wiring connections If AC power is out and the battery is ex hausted it will charge upon return of AC power...

Страница 12: ...anty if the product has not been properly installed if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been r...

Отзывы: