Copyright © Liberty Pumps, Inc. 2020 All rights reserved.

3 | EN

 

Do not modify the pump/pump system in any way. 

Modifications may affect seals, change the electrical loading 

of the pump, or damage the pump and its components.

 

All pump/pump system installations shall be in compliance 

with all applicable Federal, State, and Local codes and 

ordinances.

 

Do not remove any tags or labels from the pump or its cord.

 

Keep clear of suction and discharge openings. To prevent 

injury, never insert fingers into pump while it is connected to 

a power source.

 

The macerator has a large opening to accept the discharge 

hub of a rear discharge toilet. Do not place hand or other 

objects into this opening even if unit is unplugged. The 

macerator has razor sharp cutters within this opening.

 

Decorative covers must be installed for operation as a safety 

device is integrated into the covers to prevent unintended 

operation. The unit may start when energized the first time.

 

This product contains chemicals known to the State of 

California to cause cancer and birth defects or other 

reproductive harm. www.p65warnings.ca.gov.

 

This pump has been evaluated for use with water only.

Wear Protective Personal Equipment to protect hands as 

exposed cutter blades have sharp edges.

Do not use pumps with fluid over 104°F (40°C). Operating the 

pump in fluid above this temperature can overheat the pump, 

resulting in pump failure.

Do not use an air admittance valve or a mechanical 

spring-loaded venting device, as these devices are one-way 

valves. The air pressure in and outside the macerating pump 

unit must be equal and a “cheater” vent will obstruct the 

airflow in one direction and prevent proper toilet function.

The Ascent II macerating unit includes electronic controls and 

must be protected from direct water exposure during 

installation and use.

Sanitary fixtures connected to the macerating system must be 

located on the same floor level.

Introduction

Before installation, read the following instructions carefully. Each 

Liberty Pumps product is individually factory tested to ensure 

proper performance. Closely following these instructions will 

eliminate potential operating problems, assuring years of 

trouble-free service.
No repair work should be carried out during the warranty period 

without prior factory approval. Any unauthorized repairs void 

warranty. Contact Liberty Pumps at 1-800-543-2550.

Inspection and Storage

 Initial Inspection

The Ascent II Macerating Toilet System is shipped in three 

separate packages: the toilet tank, toilet bowl, and macerating 

unit. The shipping containers should be immediately inspected for 

damage that may have occurred in shipment.
1. Visually check the macerating unit and any spare parts for 

damage.

2. Check for damaged electrical wires, especially where they exit 

the macerating tank.

3. Check all packaging for spare parts before discarding.
Contact Liberty Pumps customer service to report any damage or 

shortage of parts.
List of included parts:
• Toilet Tank (model: Ascent II - TW)
• Toilet Bowl (model: Ascent II – RW or EW)
• Macerator (model: Ascent II - MUW)

– Macerator  tank
– Rubber couplings with clamps
– Reducing bushings
– 9V battery
– 3/16” Allen wrench
– Grease  packet

 Storage Before Use

Liberty Pumps products are shipped from the factory ready for 

installation and use. If storage is necessary, the pump should 

remain in its shipping container. It should be stored in a 

warehouse or other area that is clean, dry and temperature-stable. 

The pump and packaging should be covered to protect it from 

water, dirt and dust.

RISK OF SERIOUS INJURY OR DEATH

Ascent II - MUW

(macerating unit)

GREASE

Ascent II - EW

(elongated toilet)

Ascent II - RW

(round front toilet)

Ascent II - TW

(toilet tank)

Содержание Ascent II-ESW

Страница 1: ...Pumps com or contact Liberty Pumps at 800 543 2550 Retain dated sales receipt for warranty Serial Mfg Date Install Date Installation Manual 5755000K Copyright Liberty Pumps Inc 2020 All rights reserve...

Страница 2: ...ndoor dry location use only Serious injury or death could result Do not use an extension cord to power the product Extension cords can overload both the product and extension cord supply wires Overloa...

Страница 3: ...controls and must be protected from direct water exposure during installation and use Sanitary fixtures connected to the macerating system must be located on the same floor level Introduction Before i...

Страница 4: ...ng toilet and needs no special maintenance with normal use Any regular bathtub up to 100 gallons or shower can be used When installing these fixtures build a 6 inch high platform for the fixture to be...

Страница 5: ...ceptacle is accessible under the left decorative cover Do not install battery until the unit has been installed connected and ready for operation Auxiliary Inlets The macerator unit is equipped with t...

Страница 6: ...left side When roughing in allow for the macerator Discharge Never discharge directly into an open drain fixture manhole or rainwater drainpipe It is illegal as it constitutes a health hazard Only dir...

Страница 7: ...e 40 PVC pipe is used for the discharge and runs horizontally for 1 ft then turns 90 and rises 5 ft vertical Then it travels horizontal with another 90 turn 3 turns in total and connects with the soil...

Страница 8: ...tallation manual s provided with it Be careful when tightening fasteners as to not crack the porcelain Figure 4 Placement Options Figure 5 Toilet Connections 1 To mount the toilet to a concrete floor...

Страница 9: ...or Sewer The discharge piping can be made from 3 4 or 1 diameter PVC pipe Use long turn bends and avoid elbows where possible The connection to the soil stack or sewer pipe must be made with an appro...

Страница 10: ...scharge flange has an integrated check valve The valve is held in place by a support backing plate that is also connected to the discharge hose To access the check valve first remove the discharge fla...

Страница 11: ...e and once engaged the base can be rotated counterclockwise until it is free Accessibility to Motorized Cartridge The motorized cartridge can be accessed through the access opening or removal of the m...

Страница 12: ...acle GFCI are on Check condition of circuit breaker or fuse Ensure plug is not loose If the pumping unit thermal overload has activated it will take about 20 minutes to reset Decorative Covers Ensure...

Страница 13: ...e may be blocked The piping must be cleaned Unit not vented correctly Unit must be vented properly to open air to allow water to enter the macerator tank Confirm vent is clear Do not use a quick vent...

Страница 14: ...tor is either not plugged in supply breaker is turned off or GFCI receptacle has tripped Check electrical power source Control system in battery protection mode 1 Unplug macerator from receptacle 2 Re...

Страница 15: ...over on page 10 General plumbing During the draining of the bathtub the alarm sounds and or water backs up into the toilet The inflow is greater than the macerator can handle A full port ball valve sh...

Страница 16: ...operated or maintained per manufacturer instructions if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been...