background image

2 | EN

Copyright © Liberty Pumps, Inc. 2020 All rights reserved.

5755000K

Contents

Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 | EN
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 | EN
Inspection and Storage . . . . . . . . . . . . . . . . . . . . . . . . . 3 | EN
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 | EN
Macerating Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 | EN
Preparation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 | EN
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 | EN
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 | EN
Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10 | EN
Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12 | EN
Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16 | EN

 

Safety Guidelines

Safety Precautions

 

Accidental contact with electrically live parts, items, fluid, or 

water can cause serious injury or death.

 

Always disconnect pump (macerator) from power source 

before handling or making any adjustments. Fatal electrical 

shock could occur.

 

The pump shall be plugged into a properly fused electrical 

outlet with a ground fault circuit interrupter (GFCI) that 

conforms to current National Electric Code (NEC) and all 

applicable local codes. All wiring must be performed by 

qualified personnel.

 

All electrical and safety practices shall be in accordance with 

the National Electrical Code

®

, the Occupational Safety and 

Health Administration, or applicable local codes and 

ordinances.

 

Pump shall be properly grounded using its supplied 

grounding conductor. Do not bypass grounding wires or 

remove ground prong from attachment plugs. Failure to 

properly ground the pump system can cause all metal 

portions of the pump and its surroundings to become 

energized.

 

Do not handle or unplug pump with wet hands, when 

standing on a wet/damp surface, or in water. Fatal electrical 

shock could occur.

 

Do not lift or carry the pump by its power cord. This will 

damage the power cord, and could expose the electrically live 

wires inside the power cord.

 

The electrical power supply shall be located within the length 

limitations of the pump power cord, and for below grade 

installations it shall be at least 4 ft (1.22 m) above floor level.

 

Do not submerge macerator or allow macerator to be 

exposed to water. Macerating toilet system is acceptable for 

indoor dry location use only. Serious injury or death could 

result. 

 

 

Do not use an extension cord to power the product. 

Extension cords can overload both the product and extension 

cord supply wires. Overloaded wires will get very hot and can 

catch on fire.

Explosion hazard during installation. PVC cleaners, primers, 

and cements can release explosive vapors. These 

heavier-than-air vapors can accumulate in the tank. The heat 

of soldering or sweating copper or other metal pipe can 

ignite these vapors causing a violent explosion. If the unit is 

to be connected to copper discharge or vent piping, all 

solvent-welded PVC joints must be allowed to cure a 

minimum

 of 24 hours. The access cover must be removed to 

allow the tank to be thoroughly ventilated prior to sweating 

copper pipe near the unit.

 

These pumps are not to be installed in locations classified as 

hazardous in accordance with the National Electric Code

®

ANSI/NFPA 70.

 

This safety alert symbol is used in the manual 

and on the pump to alert of potential risk for 

serious injury or death.
This safety alert symbol identifies risk of 

electric shock. It is accompanied with an 

instruction intended to minimize potential 

risk of electric shock.
This safety alert symbol identifies risk of fire

It is accompanied with an instruction 

intended to minimize potential risk of fire.
This safety alert symbol identifies risk of 

serious injury or death. It is accompanied 

with an instruction intended to minimize 

potential risk of injury or death. 
Warns of hazards which, if not avoided, will 

result in serious injury or death.

Warns of hazards which, if not avoided, could 

result in serious injury or death.

Warns of hazards which, if not avoided, could 

result in minor or moderate injury.
Signals an important instruction related to 

the pump. Failure to follow these instructions 

could result in pump failure or property 

damage.

Read every supplied manual before using 

pump system. Follow all the safety 

instructions in manual(s) and on the pump. 

Failure to do so could result in serious injury 

or death.

RISK OF ELECTRIC SHOCK

RISK OF FIRE

Содержание Ascent II-ESW

Страница 1: ...Pumps com or contact Liberty Pumps at 800 543 2550 Retain dated sales receipt for warranty Serial Mfg Date Install Date Installation Manual 5755000K Copyright Liberty Pumps Inc 2020 All rights reserve...

Страница 2: ...ndoor dry location use only Serious injury or death could result Do not use an extension cord to power the product Extension cords can overload both the product and extension cord supply wires Overloa...

Страница 3: ...controls and must be protected from direct water exposure during installation and use Sanitary fixtures connected to the macerating system must be located on the same floor level Introduction Before i...

Страница 4: ...ng toilet and needs no special maintenance with normal use Any regular bathtub up to 100 gallons or shower can be used When installing these fixtures build a 6 inch high platform for the fixture to be...

Страница 5: ...ceptacle is accessible under the left decorative cover Do not install battery until the unit has been installed connected and ready for operation Auxiliary Inlets The macerator unit is equipped with t...

Страница 6: ...left side When roughing in allow for the macerator Discharge Never discharge directly into an open drain fixture manhole or rainwater drainpipe It is illegal as it constitutes a health hazard Only dir...

Страница 7: ...e 40 PVC pipe is used for the discharge and runs horizontally for 1 ft then turns 90 and rises 5 ft vertical Then it travels horizontal with another 90 turn 3 turns in total and connects with the soil...

Страница 8: ...tallation manual s provided with it Be careful when tightening fasteners as to not crack the porcelain Figure 4 Placement Options Figure 5 Toilet Connections 1 To mount the toilet to a concrete floor...

Страница 9: ...or Sewer The discharge piping can be made from 3 4 or 1 diameter PVC pipe Use long turn bends and avoid elbows where possible The connection to the soil stack or sewer pipe must be made with an appro...

Страница 10: ...scharge flange has an integrated check valve The valve is held in place by a support backing plate that is also connected to the discharge hose To access the check valve first remove the discharge fla...

Страница 11: ...e and once engaged the base can be rotated counterclockwise until it is free Accessibility to Motorized Cartridge The motorized cartridge can be accessed through the access opening or removal of the m...

Страница 12: ...acle GFCI are on Check condition of circuit breaker or fuse Ensure plug is not loose If the pumping unit thermal overload has activated it will take about 20 minutes to reset Decorative Covers Ensure...

Страница 13: ...e may be blocked The piping must be cleaned Unit not vented correctly Unit must be vented properly to open air to allow water to enter the macerator tank Confirm vent is clear Do not use a quick vent...

Страница 14: ...tor is either not plugged in supply breaker is turned off or GFCI receptacle has tripped Check electrical power source Control system in battery protection mode 1 Unplug macerator from receptacle 2 Re...

Страница 15: ...over on page 10 General plumbing During the draining of the bathtub the alarm sounds and or water backs up into the toilet The inflow is greater than the macerator can handle A full port ball valve sh...

Страница 16: ...operated or maintained per manufacturer instructions if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been...

Отзывы: