DL-AS61U-H2 Installation Guide
16
The
EDID
menu allows you to select a desired EDID table to used for source compatibility communication.
To select a pre-defined EDID setting, choose the desired EDID and then click
Confirm
.
To use a user-defined EDID setting, check on either
User -defined 1-4
option, load the EDID (.bin) file from your
computer, then click
Apply
.
If EDID table fails, the switcher will default to 1080p.
To use the GUI EDID feature in this tab you must select all 4 EDID dip switches on the back of the DL-AS61U-H2
to the ON (1) position for all pre-defined options in the EDID menu above.
To use the User Defined EDID options in the GUI, you must adjust the EDID dip switches to the following positions
for their respective option:
User-Defined 1: 1011 (ON, OFF, ON, ON)
User-Defined 2: 1100 (ON, ON, OFF, OFF)
User-Defined 3: 1101 (ON, ON, OFF, ON)
User-Defined 4: 1110 (ON, ON, ON, OFF)
Audio ON/OFF Control