10
CV Settings
CV
Designation
Range
Factory
Setting
1
Address block
1 – 63
1
7
Version
—
—
8
Manufacturer
8
—
9
Address range
0 – 7
0
60 Output A, mode
1
0 – 255
16
61 Output A, dim
0 – 255
255
62 Output A, period
0 – 255
4
63 Output B, mode
1
0 – 255
16
64 Output B, dim
0 – 255
255
65 Output B, period
0 – 255
4
66 Output C, mode
1
0 – 255
16
67 Output C, dim
0 – 255
255
68 Output C, period
0 – 255
4
69 Output D, mode
1
0 – 255
16
70 Output D, dim
0 – 255
255
71 Output D, period
0 – 255
4
1
See separate tables on Page 11
Address Table
Addresses
Range
CV 9
1 – 252
1
0
257 – 508
2
1
513 – 764
3
2
769 – 1020
4
3
1025 – 1276
5
4
1281 – 1532
6
5
1537 – 1788
7
6
1793 – 2044
8
7
Note:
Depending on the locomotive controller, the full
range of addresses is not available.
Содержание 55525
Страница 1: ...Weichendecoder 55525 ...