21
NO
YES
NO
NO
YES
NO
YES
YES
NO
NO
YES
YES
YES
NO
NO
NO
YES
(1) (2)
(3)
(1) (2)
(3)
5
4
Dry
Steam
Steam
Dry
Is water supply shut-off?
Is the tap opened?
When you press both Rinse button and Temp.
button simultaneously, is the water level frequency
below 240?
Is the inlet valve filter clogged with impurity?
Is resistance between each terminal of INLET
VALVE ASSEMBLY is 2~8
k
Ω
?
Check the voltage of the inlet valve connector
220-240V AC.
(Refer to 7-2 QC TEST MODE)
Is water supplied?
Are replaceptacles correctly connected to the
terminals of the INLET VALVE ASSEMBLY?
Is detergent put in the correct compartment of
the drawer?
Is the detergent hardened?
Open the tap.
Check the AIR CHAMBER
and the tube clogged
with impurity.
Clean the filter.
Replace the INLET VALVE
ASSEMBLY.
Check electrical
connection.
Replace the MAIN PWB
ASSEMBLY
Refer to
^
NO WATER SUPPLY
_
Check the wiring on the
dispenser.
Put the detergent in the
correct position
PRE+MAIN
MAIN WASH
: Detergent
Clean the drawer.
NO WATER SUPPLY
DETERGENT DOES NOT FLOW IN