background image

Wireless Remote Control

Inserting Battery

1

Push out the cover on the back of the 

remote control with your thumb.

2

With the plus and minus poles facing as

marked, and insert one new AAA 1.5 V

battery.

3

Reattach the cover.

NOTE

 

One new battery are supplied with the air

conditioner for use in the remote control.

 

Do not use a rechargeable battery. Make sure 

that the battery is new.

 

In order to prevent discharge, remove the 

battery from the remote control if the air 

conditioner is not going to be used for an 

extended period of time.

 

Keep the remote control away from extremely 

hot or humid places.

 

To maintain optimal operation of the remote 

control, the remote sensor should not be 

exposed to direct sunlight.

5

Temperature Control

The thermostat monitors room temperature

to maintain the desired temperature. The

thermostat can be set between 16 °C–30 °C

(60 °F–86 °F). Press  

 or 

 arrows to 

increase or decrease temperature setting.

6

Remote Control Sensor

Clean Filter

The Clean Filter (Limpieza Filtro) LED lights 

up to notify you that the filter needs to be 

cleaned. After cleaning the filter, press

Temp

 

 and 

 together on the control 

panel to turn off the Clean Filter (Limpieza 

Filtro) light. 

NOTE

 

control panel, not the remote control.

 

This feature is a reminder to clean the air 

light turns on after 250 hours of operation.

filter for more efficient operation. The LED

The filter reset must be done using the

7

NOTE

 

Auto Restart:

 If the air conditioner turns off due 

to a power outage, it will restart automatically 

once the power is restored, with the same 

settings as were set before the unit turned off.

 

Energy Saver (Ahorro Energía) :

 

The unit 

defaults to the Energy Saver (Ahorro Energía) 

mode each time the unit is switched on except 

in Fan (Vent.) mode or when power is restored 

after an electrical power outage.   

 

The remote control will not function properly if 

the AC infrared sensor is exposed to direct light  

or if there are obstacles between the remote 

controller and the air conditioner.

.

17

OPERATION

EN

Содержание W081CE SU0

Страница 1: ... ENGLISH Read this owner s manual thoroughly before operating the appliance and keep it handy for reference at all times MODELS W081CE SU0 MFL70643101 MFL70643101 Rev 03_092820 www lg com Copyright 2018 2020 LG Electronics Inc All Rights Reserved ...

Страница 2: ... Breaker Installation 14 Drainage Optional 15 Space for Outside Air Flow 15 Unit Installation 16 OPERATION 16 Control Panel and Remote Control 17 Wireless Remote Control 18 Ventilation 18 Air Direction 18 Slinger Fan 13 Installation Overview 14 How to Install the Unit 20 TROUBLESHOOTING 20 Before Calling for Service 20 Normal Sounds You May Hear 19 MAINTENANCE 19 Air Filter ...

Страница 3: ... You may be injured or cause damage to the product if you do not follow instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what may happen if the instructions are not followed EN The following symbols are displayed on units This symbol indicates that this appliance uses a flammable refrigerant If the refrigerant is i...

Страница 4: ...se a dedicated circuit Do not disassemble or modify the product Adhere to all industry recommended safety procedures including the use of long sleeved gloves and safety glasses Use care when unpacking and installing The edges of the product may be sharp Disconnect the power cord or circuit breaker before installing or servicing the appliance Keep packaging materials out of the reach of children Th...

Страница 5: ...sulated and the wall receptacle is grounded to make sure the receptacle is properly grounded Disconnect the power cord from the adapter using one hand on each Otherwise the adapter ground terminal might break Do not use the appliance with a broken adapter plug Situations when the appliance will be disconnected often Do not use an adapter plug in these situations Unplugging the power cord frequentl...

Страница 6: ...ppliance Do not use waxes thinners or harsh detergents Do not step on or place heavy objects on top of the appliance Do not drink water drained from the appliance are used simultaneously Remove the batteries if the remote control is not to be used for an extended period of time Never mix different types of batteries or old and new batteries for the remote control consult a doctor Do not recharge o...

Страница 7: ...the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks No Smoking signs shall be displayed No ignition sources Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work A degree of ventilation shall continue during the period that the work is carried out The ventilat...

Страница 8: ...lly safe components are the only types that can be worked on while live in the presence of a flammable atmosphere The test apparatus shall be at the correct rating Replace components only with parts specified by the manufacturer Other parts may result in the ignition of refrigerant in the atmosphere from a leak Repair to intrinsically safe components Cabling will not be subject to wear corrosion e...

Страница 9: ...le In addition to conventional charging procedures the following requirements shall be followed Charging procedures Before carrying out this procedure it is essential that the technician is completely familiar with the equipment and all its detail It is recommended good practice that all refrigerants are recovered safely Prior to the task being carried out an oil and refrigerant sample shall be ta...

Страница 10: ...rigerants In addition a set of calibrated weighing scales shall be available and in good working order Hoses shall be complete with leak free disconnect couplings and in good condition Before using the recovery machine check that it is in satisfactory working order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigeran...

Страница 11: ... for example an operating electric heater The appliance shall be stored in a well ventilated area where the room size corresponds to the room area as specified for operation current valid certificate from an industry accredited assessment authority which authorises their Technical Safety Any person who is involved with working on or breaking into a refrigerant circuit should hold a competence to h...

Страница 12: ...rator 2 Air Guide 3 4 Shround 5 Compressor 6 Condenser 7 Base Pan Power Cord 1 Control Panel 2 Remote Control 3 Air Filter 4 5 6 Front Grille 7 8 Cabinet Air Outlet 1 2 3 4 5 6 7 7 8 6 1 4 5 3 2 Horizontal Air Deflector Vertical Louver Vertical Air Deflector Horizontal Louver ...

Страница 13: ...river Level Pencil Tape measure Cutting knife Scissors Read thoroughly and follow all directions provided A circuit breaker must be installed between the power source and the unit if the plug is not used see illustration below NOTE Use 15 A circuit breaker INSTALLATION Main Power source Circuit Breaker Use a circuit breaker or time delay fuse ...

Страница 14: ...ight tilt Fence Awning Heat radiation Cooled air CAUTION The external grille must be exposed outside for air discharge 10 15 mm Over 50 cm Foam 70 150 cm Level 1 4 Bubble CAUTION Take care when inserting the drain pipe Push away from the sharp edge to avoid slipping and injuring yourself 1 Remove the rubber cap from the hole under the base pan and pushing 2 Press the drain pipe into the hole by ha...

Страница 15: ...5 BRICK CUT AWAY TO CLEAR LOUVRES 45 BRICK CUT AWAY TO CLEAR LOUVRES BRICK WALL AIR IN AIR IN BRICK WALL AIR OUT TOP VIEW OPTION B CAUTION The power cord must be connected to an independent circuit The green wire must be grounded Stuff the foam around the unit to prevent air and insects from getting into the room The Foam Around the unit ...

Страница 16: ...he fan circulates air but the compressor does not run Use the Fan Speed Nivel Vent button to set fan speed to High Medium or Low In this mode you cannot adjust the set temperature Dry Deshum This mode is ideal for rainy and damp days to dehumidify the room rather than cooling it significantly Humidity is removed from the room by the combination of compressor operation and the fan speed fixed at Lo...

Страница 17: ...ecrease temperature setting 6 Remote Control Sensor Clean Filter The Clean Filter Limpieza Filtro LED lights up to notify you that the filter needs to be cleaned After cleaning the filter press Temp and together on the control panel to turn off the Clean Filter Limpieza Filtro light NOTE control panel not the remote control This feature is a reminder to clean the air light turns on after 250 hours...

Страница 18: ...ertical louvers to the left or right Direction up or down NOTE When the weather is extremely hot the unit may turn off automatically to protect the compressor Slinger Fan This air conditioner is equipped with a slinger fan See drawing The fan s outer ring picks up the condensed water from the base pan if the water level gets high enough The water is then picked up by the fan and expelled through t...

Страница 19: ...detergent solution Wash the cabinet with mild soap or detergent and lukewarm water then polish using liquid appliance wax NOTE condenser coils outside of unit should be To ensure continued peak efficiency the checked periodically and cleaned if clogged with soot or dirt from outside air For repair and maintenance contact a LG Electronics Customer Information Center See the warranty card for detail...

Страница 20: ...you may hear the sound of rushing air being moved by the fan Today s high efficiency compressors may have a high pitched chatter during the cooling cycle 3 Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation 4 Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrect installation 5 Pinging...

Страница 21: ...e Power failure If power failure occurs turn the mode control to off When power is compressor overload The air filter is dirty Clean the filter at least every 2 weeks See the MAINTENANCE Cleaning the Air Filter section The cooling coils are iced over Ice may block the air flow and obstruct the air conditioner from properly cooling the room Set the Fan Speed High at Fan or Cool mode The temp contro...

Страница 22: ...eas with little humidity normal for a longer period in very humid areas from the cabinet front to the rear Dirty air filter air restricted Clean air filter Noise when unit is Room too cold cooling Window vibration poor installation Refer to installation instructions or check with installer Air movement sound This is normal If too loud set to lower FAN Speed Remote control not located within range ...

Страница 23: ...Sor Juana Inés de la Cruz No 555 Col San Lorenzo Industrial Tlalnepantla de Baz Estado de México C P 54033 Página web http www lg com mx Tel 55 5321 1919 ...