INSTALLATION
How to Install the Unit
1
Measure the space for installation to assure
a good fit. The air conditioner must be
2
Avoid exposure to direct sunlight.
installed firmly into place to prevent vibration
and noise.
There must be at least 50 cm (20 in.) of
cleared space around the rear of the unit.
Obstacles restricting the airflow may reduce
the cooling efficiency of the unit.
3
Remove all obstacles from the rear of the unit.
towards the outside to allow condensed water
to drain. (About 10~15 mm or 1/4 bubble with
Level)
4
The unit should be installed with a slight tilt
Fence
Awning
Heat
radiation
Cooled air
CAUTION
●
The external grille must be exposed outside
for air discharge.
10~15 mm
Over 50 cm
Foam
70-150 cm
Level
1/4 Bubble
CAUTION
●
Take care when inserting the drain pipe.
Push away from the sharp edge to avoid
slipping and injuring yourself.
1
Remove the rubber cap from the hole under
the base-pan.
and pushing.
2
Press the drain pipe into the hole by hanging
on the bottom of the drain pipe. (You can
3
Connect the drain hose to the outlet located
satisfy your particular needs. Drain hose is not
supplied)
purchase the drain hose or tubing locally to
Drainage (Optional)
To drain the excess water, remove the drain cap
The base-pan may overflow due to high humidity.
from the base pan of the unit and secure the drain
pipe.