THE INDOOR UNIT INSTALLATION
ENGLISH
600
Ø17
103
87
1
The Outer diameter of Drain Hose (which is supplied with indoor unit) is 17 mm at connecting
end, 600 mm long.
2
Use commercial rigid PVC pipe for extension.
3
Insulate the indoor drain pipe with 10 mm or more of insulation material to prevent
condensation.
NOTE
The drain pipe should be inclined downward so that water will flow smoothly without any
accumulation.
(Unit: mm)
Installation Plate
Molding
4 screw (M*25L)
6 screw (M*25L)
Installing Indoor unit
Installation on the Floor
1
Fix up using 6 screws for floor installation.
Installation on the Wall
1
Fix up the installation plate using 5 screws and the indoor unit using 4 screws.
2
The installation plate should be fixed on a wall which can support the weight of the indoor
unit.
64
159
(700)
26
647
180
140
(600)
574
170
170
210
30.5
30.5
140
160
(Unit: mm)